14
1. "STOP!" Read the safety information on previous
page.
2. To access controls, open the bottom grille.
3. Turn the valve control knob to the "OFF" position.
To do this, you must turn the knob clockwise
to the "Pilot" position, and then press
in and continue turning clockwise
to
the "OFF" position.
GAS CONTROL VALVE
NOTE: Knob cannot be turned from "PILOT" to
"OFF" unless knob is pushed in slightly. Do not
force.
4. WAIT FIVE (5) MINUTES TO CLEAR OUT ANY
GAS. Then smell for gas, including near the
floor. If you then smell gas, STOP! Follow "B"
in the safety information above. If you don't
smell gas, go to the next step.
5. The pilot should not require accessing for lighting
purposes. The pilot is located inside the
combustion chamber. If it is necessary to
access the pilot, follow the instructions in
Section 5.1 and 5.4 for glass door removal and
replacement.
2.3
LIGHTING INSTRUCTIONS
THERMOCOUPLE
THERMOPILE
6. To put the control in the pilot position, turn the
control knob counter-clockwise
to
the "Pilot" position.
7. To light the pilot depress the control knob and then
depress the red piezo button until it makes a
clicking sound. It may be necessary to repeat this
step. If the pilot does not light after 10 seconds,
go back to step 3. The control knob should be held
down for a MINUTE after pilot ignition.
• If the control knob does not pop out when
released, STOP-shut off the gas supply to
the heater control valve, and IMMEDIATELY
call your service technician or gas supplier.
• If the pilot will not stay lit after two tries, turn
the control knob to the "OFF" position and
call your service technician or gas supplier.
8. After the pilot has been lit, the burner can be turned
on by turning the knob counter-clockwise
to the "ON" position. Flip the ON/OFF
switch to the "ON" position.
9. Close the bottom grille.
LIGHTING INSTRUCTIONS
TO TURN OFF GAS APPLIANCE
1. Turn ON/OFF switch to "OFF".
2. Open the bottom grille.
3. Turn the valve control knob clockwise
to the "Pilot" position, then depress knob and
continue turning to "OFF" position.
4. Close the bottom grille.
PILOT BURNER