HeatLink
®
Mixing Valve Reset Control Stk# 31360
®
Link
Heat
www.heatlinkgroup.com
H
e
a
tL
in
k
38
ELECT 5.5a
StatLink
®
Activating Low Temp. plus Independent High Temp. Circuits
Application:
StatLink
®
controls activating individual zone motors for both primary and secondary circuit
loops. For the secondary low temp. circuit, StatLink
®
activates the indoor/outdoor control, which
in turn activates the boiler plus the primary (P-3) and system (P-1, P-2) pumps. For the high
temp. primary circuit StatLink
®
controls activate the boiler and the primary (P-3) and system (P-2)
pump. Medium temperature secondary circuit off heat exchanger from DHW tank is controlled
by StatLink
®
which activates system pump (P-4) (no tie-in to boiler required).
Note:
• Drawings are for HeatLink
®
suggested
electrical schematics only! User must determine if electrical schematic will work for their particular application.
User must also confirm all HeatLink
®
schematics with manufacturer schematics of each particular control chosen.
• In all cases manufacturer equipment schematics will take precedence over HeatLink
®
electrical schematics.
• All wiring as per applicable electrical codes!
4
4
4
4
2
2
2
2
2
2
Outdoor Sensor
Boiler
Optional Boiler Return Sensor
Fan Coi
l
1
P-2
P-3
P-1
Zone
Thermostats
Class II
Transformers
Thermostats
Indoor/Outdoor
Controller
R-1
Supply Sensor
110/220
V
ac
31360
SL1
SL2
46643
Timer
DHW
Aquastat
Pool
/
Hot
Tub Heat
Aquastat
Pool
/
Hot
Tub Heat
Exchanger
P-4
R-2