background image

 

9

 

 

FW7I 23/07/14 

 

by first de-ashing and then using small pieces of wood and plenty of air to get flames issuing from the wood 
again. 

 
Refuelling on to a low fire bed 

If there is insufficient burning material in the fire bed to light a new fuel charge, excessive smoke emission 
can occur. Refuelling must be carried out onto a sufficient quantity of glowing embers and ash that the new 
fuel charge will ignite in a reasonable period. If there are too few embers in the fire bed, add suitable 
kindling to prevent excessive smoke 

 
Fuel Overloading 

Four good size logs is a sufficient quantity of fuel to achieve the rated output from this appliance. Never 
exceed this amount of fuel and never stack the fuel too high in the stove so as it touches the baffle or blocks 
the tertiary air holes as this may cause smoke to be produced.  
 

 
 
Shutting Down 

The stove will normally shut down by itself as the fuel is consumed. In order to shut down the stove for 
other reasons, close the primary air controls (if open), then close the secondary air control. If the controls are 
left in this position, the fire will eventually burn out. If you want to revive the fire open the secondary air 
controls fully. 

Warning! - 

The stove will remain 

very hot 

for a considerable time after the fire has died down or been 

extinguished. 

Warning!- Petroleum coke fuels or household waste must not be burnt on this appliance.  

 

Maintenance 

Inspect the inside of the firebox and above the baffle plate every week during use. 

See chimney cleaning 

section in section 3.1 Warnings and Important Information.

 Inspect the inside of the stove and the flue 

ways and ensure they are 100% clear after a period of disuse (e.g summer). 

Only use manufacturers 

recommended replacement parts on the appliance 
 
Seasonal Use 

Remove the baffle and inspect the inside of the stove and the flue ways and ensure they are 100% clear after 
a period of disuse, for example if the stove is not used during the warmer periods of the year. Also set the air 
controls to 50% to keep the appliance ventilated and stop the build-up of any moisture inside.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for FW7i

Page 1: ...in the correct use of the appliance and operation of controls Important This product must be installed by a suitably qualified installer Heat Design Ltd 30 60 Hawthorn Road Western Industrial Estate...

Page 2: ...lue Draught 4 Connection to Chimney 5 Material Clearances 5 Hearths 5 Commissioning Handover 5 5 Technical Data 6 6 Operating Instructions 6 Air controls 6 Cleaning 7 Fuels 8 Notes on Wood Burning 8 N...

Page 3: ...stove Also remove the ashpan and its contents from the stove Secure the fixing bar and the tightening screw to the stove as shown in fig 2 Do not put on the wingnut until the stove is in place Place t...

Page 4: ...cularly important for England and Wales and can be downloaded for no cost at http www planningportal gov uk england professionals en 4000000000503 html Also of importance are Approved documents L1 A a...

Page 5: ...nd not more than 200mm If any of these requirements are not met the chimney should be lined by a suitable method The chimney must be swept before connection to the stove Where the chimney is believed...

Page 6: ...of a cavity wall at the rear If these dimensions are not met further protection for any combustible materials must be provided The walls of the fireplace recess and the hearth must be made of non com...

Page 7: ...rly it must be used correctly It is essential that the stove has an adequate air supply for combustion and ventilation The primary and secondary air inlets must be kept clear from obstruction Warning...

Page 8: ...eath the bed as this may cause damage to the grate Cleaning Glass Despite the advanced air wash system provided the glass will still need cleaning from time to time depending on the fuel quality and b...

Page 9: ...if you wish to check your wood source is correct Notes on Burning Solid Fuel See section 6 6 on lighting the stove After the fire has become established close the airwash until it is approximately 25...

Page 10: ...stove for other reasons close the primary air controls if open then close the secondary air control If the controls are left in this position the fire will eventually burn out If you want to revive th...

Page 11: ...er persistent fume emission is potentially dangerous and must not be tolerated If fume emission does persist then the following immediate action should be taken 1 Open doors and windows to ventilate r...

Page 12: ...11 FW7I 23 07 14 8 0 Stove Dimensions Fig 3 FW7i Insert Stove All dimensions in mm unless otherwise stated Dimensions are approximate and are subject to change without prior notice 250 105 305...

Page 13: ...attends any stove problem that is not related to product failure 6 Where can I get spare parts Your local Heat Design Stove retailer will be pleased to supply spare parts and to provide any other inf...

Page 14: ...rol including handle Y1FWF08D33E 06 Side Plate Left fireboard Y1HDI07D06A 28 Front YIHDI04D34E 07 Side Plate Right fireboard Y1HDI07D07A 29 Base YIHDI07D35E 16 Baffle Plate Y1HDI07D19A 36 Outer skin f...

Reviews: