12

...

Remarks :

(1)

 

When HP stop running in 30 seconds ,water pump will shut off automatically 

.

(2)

 

LED wire controller can operate the water pump after connected additional cable to 

    

the pump device in the position of “PUMP” terminal accurately .

(3)

 

It is necessary to put an extra 3-phase transfer device for 3 phase water pump

Parameter

Meaning

Range 

Default

Remarks 

0

To set the entering water temp. 
under cooling mode 

8-35

28

Adjustable

1

To set the entering water temp. 
under heating mode

15-35

28

Adjustable

Entry into defrosting time period

2

30-90MIN

40MIN

Adjustable

3

4

5

6

7

8

9

A

b

C

d

E

F

G

H

Terms of Entry defrosting function  -30

to 0

-7

Adjustable

Terms of Exit defrosting function

2 to 30

13

Adjustable

Time of Exit defrosting

1 to 12MIN

8MIN

Adjustable

Mode : 0 Cool  1 Heat and Cool  
2 Heat and cool + auxiliary elec. 
heating   3 Heat

0-3

3

Adjustable

Mode selection of Electronic 
expansion valve

0-1

1 (auto)

Adjustable

Superheat for heating target

-15

-15

3

Adjustable

Superheat for cooling target

-15

-15

10

Adjustable 

Manual adjustment steps of 
electronic expansion valve

18-94

70

Adjustable

Inlet water temperature

-9-99

Exact testing 
by value

Outlet water temperature

-9-99

Condenser temperature 
under heating mode 

Gas return temperature

Ambient temperature

Condenser temperature 
under 

 mode

Cooling

Actual steps of electronic 
expansion valve

N*5

-9-99

-9-99

-9-99

-9-99

Exact testing 
by value
Exact testing 
by value
Exact testing 
by value
Exact testing 
by value
Exact testing 
by value
Exact testing 
by value

   

ATTENTION

:

HP running parameters must be checked after installation and before first used.

When HP is running, LED displays water inlet temperature 

When HP is stopping, LED wire controller displays the actual time.

When HP running, the running mode ( cooling or heating) and water temp could be 

changed. Other parameters only changeable when HP stopping.

!

5.4 

 

 

RUNNING DATA SETTING

6. Maintenance

   

(1) 

 

You

 

should

 

check

 

the

 

water

 

supply

 

system

 

regularly

 

to

 

avoid

 

the

 

air

 

entering

 

the

 

system and occurrence of low water flow, 

 

because

 

it

 

would

 

reduce

 

the

 

performance and reliability of HP unit.

(2) 

 

Clean your pools and filtration

 

system

 

regularly

 

to

 

avoid

 

the

 

damage

 

of

 

the

 

unit

 

as

 

a result of the dirty of clogged filter.

(3) Keep the HP unit dry,

 

clean,

 

well-ventilated and always clean side of the

 

heat 

exchanger which can maintain a good heat exchange and energy saving.

(4) 

 

Only a qualified service technician is allowed

 

to

 

operate

 

pressure

 

of

 

the

 

refrigeration system. 

(5) 

 

Check power cable connection,

 

if

 

heat

 

pump

 

start

 

to

 

operate

 

abnormally,

 

you

 

should turn it off and contact with qualified technicians.

(6) 

 

You should

 

discharge

 

the

 

water

 

from

 

water pump and other water system, 

 

to 

prevent from the freezing damage in winter seasons.

(7) 

 

You should discharge the water from bottom of water pump if HP

 

unit

 

will

 

stop

 

running for

 

a

 

long

 

time. 

 

In

 

another

 

way, 

 

you

 

should

 

check

 

the

 

units

 

thoroughly

 

and

 

fill

 

the system with water fully before the unit start to run again.

  

  

  

  

  

  

 

 

     

 

 

 

 

 

   

  

  

  

  

  

  

  

  

  

  

  

  

...

13

Summary of Contents for swimming pool heat pump

Page 1: ...SWIMMING POOL HEAT PUMP User Manual ...

Page 2: ...at 7 to 40 In order to offer qualified reliable and flexible heat pump unit to our customer please read this manual carefully before installing operating and troubleshooting then process accordingly This manual includes all necessary information The heat pump unit must be installed by qualified technicians from after sales center or authorized distributor Operating and maintaining according to rec...

Page 3: ...060 380 600 1065 380 670 1065 380 955 56 72 105 mm kg kg Above data is subject to modification without notice 3 Installation 3 1 Installation illustration ATTENTION Please follow these steps when operating the first time 1 Open valve and charge water 2 Make sure that the pump and the water in pipe have been filled with water 3 Close the valve and start the unit NOTE The factory only provides the h...

Page 4: ...isconnect A disconnect means circuit breaker fused or un fused switch should be located within sight of and readily accessible from the unit This is common practice on commercial and residential heat pumps It prevents remotely energizing unattended equipment and permits turning off power at the unit while the unit is being serviced 6 When install a bypass it should be not exceed 30 of nominal flow...

Page 5: ...eed to adjust its initial startup Time Delay HP unit should be equipped with a 3 minute built in solid state re start delay protection Time delay control is an integral part of the circuit control it can eliminate restart cycling and contactor chatter The time delay will automatically restart the HP unit approximately 3 minutes after each control circuit interruption Even a brief power interruptio...

Page 6: ... 2 to 30 default setting 13 Parameter 5 Time of Exit defrosting 1 to 12MIN default setting 8MIN 1 0 MODE HEAT Parameter 8 Heating target for superheat 15 15 default setting 3 1 0 MODE HEAT Parameter 6 Mode 0 Cool 1 Heat and Cool 2 Heat and cool auxiliary elec Heating 3 Heat default setting 3 1 0 MODE HEAT Parameter 7 Mode selection of Electronic expansion valve 0 to 1 default setting 1 auto Note P...

Page 7: ...can check water in water out Condenser ambient temperature 3 Mode can be changed while running 4 When the unit is switched off current time is displayed Time setting Press to set the time and press or to adjust the time After pressed the again to store the new data When setting the time and can not work TIMER ON SETTING Press to set the time for HP start to run and press or to adjust starting time...

Page 8: ...sting by value Exact testing by value Exact testing by value Exact testing by value Exact testing by value Exact testing by value ATTENTION HP running parameters must be checked after installation and before first used When HP is running LED displays water inlet temperature When HP is stopping LED wire controller displays the actual time When HP running the running mode cooling or heating and wate...

Reviews: