background image

(11) 

 

It is required to increase the discharge pipe to prevent freezing in cold season,

 

to 

         

put T fitting and ball valve to facilitate changing the water in winter or emptying the 

         

water out of system to prevent freezing when HP stop operating at the ambient 

         

temperature below zero ,otherwise the unit may be damaged .

(12) 

 

It is suggested to install the quick adaptor in front of water in-out connection, 

     

which could discharge water easily to prevent water freezing, and be convenient 

     

for maintenance and service. 

(13) 

 

When unit running ,there will be some condensation water discharged from the 

      

bottom,

 

please hold the drainage nozzle (accessory ) into the hole and clip well,

      

and then connect a pipe to drain the condensation water out.

(14) 

 

If water pressure is over 10 KPA, or water flow rate is more than 11 cubic meters 

     

through heat exchanger, it is necessary to install the by-pass pipe in water system.

        

Pressure

-

type

 

Chlorinator

 

or

 

Brominator

 

P

-

trap

Filter

Chlorinator

Check

-

valve

Water

 

pump

Check

-

valve

In-line Chlorinator or Brominator

3.3

 

 

 

The

 

location of chemical's instruction to your system is also

critical to the heater's life

.

 

 

 

 

 

 

 

 

 

        

 

 

 

 

If an automatic chlorinator or brominates is used, it must be located downstream 
of the heater.
A trap must be installed between the chlorinator and the heater to prevent chlorine 
return into the heat pump. (See below pictures)

Disconnect: 

A disconnect means (circuit breaker, fused or un-fused switch) should

 

be 

located

 

within sight of and readily accessible from the unit. This is common practice on 

commercial

 

and residential heat pumps.

 

It prevents remotely-energizing unattended 

equipment and permits turning off power at the unit while the unit is being serviced.
 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

(6)

 

When install a bypass, it should be not exceed 30% of nominal flow rate 

.

(7)  Must make Water level higher than the circulation pump location

.

(8)

 

Below picture show the minimum required distance on each side of pool heat pump 

    

unit.

(3)

 

The

 

unit

 

can

 

be

 

installed

 

almost

 

anywhere

 

in

 

the

 

outdoors

.

 

To

 

get

 

a

 

good 

    

performance ,it needs to meet the three factors :

    

a) Good ventilation    

    

b) Stable and reliable power supply   

    

c) Recycled water system 

   

 The

 

difference

 

from

 

gas

 

water

 

heater, it should not bring environmental pollution or 

    

have the installing problems in-windy areas.

(4)

 

The

 

unit

 

should

 

not

 

be

 

installed

 

in

 

a

 

limited

 

air

 

ventilation

 

area ,or placed in a bush 

    

where

 

it

 

will

 

block

 

the

 

air inlet 

.

These location deny the unit of a continuous source 

    

of

 

fresh

 

air .

 

When

 

seasons

 

changing ,

 

it may stick leaves on 

 

the evaporator coil ,

    

thereby reducing its efficiency and impact of its service life .

(5) For indoor installation, please consult more instruction from technicians.

Air

 

outlet

Air

 

inlet

(9) 

 

Typically, the pool heat pump unit should be installed aside the pools, less than 7.5 

   

meters distance. 

(10) 

 

To get the best heat exchange of heat pump unit, it should be matched the normal 

      

rate of water flow recommended in specification sheet. 

04

...

...

05

Summary of Contents for swimming pool heat pump

Page 1: ...SWIMMING POOL HEAT PUMP User Manual ...

Page 2: ...at 7 to 40 In order to offer qualified reliable and flexible heat pump unit to our customer please read this manual carefully before installing operating and troubleshooting then process accordingly This manual includes all necessary information The heat pump unit must be installed by qualified technicians from after sales center or authorized distributor Operating and maintaining according to rec...

Page 3: ...060 380 600 1065 380 670 1065 380 955 56 72 105 mm kg kg Above data is subject to modification without notice 3 Installation 3 1 Installation illustration ATTENTION Please follow these steps when operating the first time 1 Open valve and charge water 2 Make sure that the pump and the water in pipe have been filled with water 3 Close the valve and start the unit NOTE The factory only provides the h...

Page 4: ...isconnect A disconnect means circuit breaker fused or un fused switch should be located within sight of and readily accessible from the unit This is common practice on commercial and residential heat pumps It prevents remotely energizing unattended equipment and permits turning off power at the unit while the unit is being serviced 6 When install a bypass it should be not exceed 30 of nominal flow...

Page 5: ...eed to adjust its initial startup Time Delay HP unit should be equipped with a 3 minute built in solid state re start delay protection Time delay control is an integral part of the circuit control it can eliminate restart cycling and contactor chatter The time delay will automatically restart the HP unit approximately 3 minutes after each control circuit interruption Even a brief power interruptio...

Page 6: ... 2 to 30 default setting 13 Parameter 5 Time of Exit defrosting 1 to 12MIN default setting 8MIN 1 0 MODE HEAT Parameter 8 Heating target for superheat 15 15 default setting 3 1 0 MODE HEAT Parameter 6 Mode 0 Cool 1 Heat and Cool 2 Heat and cool auxiliary elec Heating 3 Heat default setting 3 1 0 MODE HEAT Parameter 7 Mode selection of Electronic expansion valve 0 to 1 default setting 1 auto Note P...

Page 7: ...can check water in water out Condenser ambient temperature 3 Mode can be changed while running 4 When the unit is switched off current time is displayed Time setting Press to set the time and press or to adjust the time After pressed the again to store the new data When setting the time and can not work TIMER ON SETTING Press to set the time for HP start to run and press or to adjust starting time...

Page 8: ...sting by value Exact testing by value Exact testing by value Exact testing by value Exact testing by value Exact testing by value ATTENTION HP running parameters must be checked after installation and before first used When HP is running LED displays water inlet temperature When HP is stopping LED wire controller displays the actual time When HP running the running mode cooling or heating and wate...

Reviews: