Note:
Please make sure the water pump is running in circulation with adequate rate of
water flow.
Startup Procedure
after Installation is completed, and please follow these steps:
(1)
Turn on your filter pump ,check water leaks and verify flow of swimming pool
(2)
Turn
on
the
electrical
power
supply
to
the
unit, then
press
the key ON/OFF of wire
controller, it should start in several seconds.
(3)
After
running
a
few
minutes
make
sure
the
air
ventilation
from
the
side
(top) of the
unit is cooler ( Between 5
℃
and
10
℃
)
(4)
When
turn
off
the
filter
pump, the
unit
should
also turn off automatically, if not, then
adjust the flow switch
(5)
Allow
the
unit
and
pool
pump
to
run
24
hours
per
day
until
the
water
reaches
the
desired
temperature.
When
thetemperature
reaches
the setting value,
the HP unit
will
shut
down,
when
the
pool
temperature
drops
more
than 1
℃
,
please restart (as
long as HP unit is running )
Water Flow Switch:
It
is
equipped
with
a
flow
switch
for
protecting
the HP unit running with adequate water
flow rate .It will turn on when the pool pump runs and shut it off when the pump shuts off.
If
the
pool
water
level
higher
than
1 m
above
or
below
the
heat
pump's
automatic
adjustment knob, your dealer may need to adjust its initial startup.
Time Delay:
HP unit should be equipped with a 3-minute built-in solid-state re-start delay protection
.
Time
delay
control
is
an
integral
part
of
the
circuit
control, it
can
eliminate
restart
cycling and contactor chatter.
The
time
delay
will automatically restart the HP unit approximately 3 minutes after each
control
circuit interruption.
Even a brief power interruption will activate the solid state 3
minute
restart delay and prevent the unit from
the
starting
until
the
3
minutes
countdown
is completed.
4. Initial Startup of the unit
1
0
HE AT
LED display
Press
to
adjust the water
temperature
Press
to set Timer on
Press to set Timer off
Press to set the Time
Press to turn
on and turn off the Unit
Operation mode
instruction
5. Operation Heating Only
5.1
The functions of LED wire controller
(1) Long press "
" 5 seconds to enter operating parameter setting interface
.
(2) Under parameter setting, Press
and
hold for 5 seconds to enter operating
parameter setting interface
(3) Under parameter setting, Press "
"again to start setting parameters from 0 to
A#, (see operation parameter table)
.
(4) Leave it 8 seconds, LED will display water in temperature (under running) or time
(until stops)
.
(5)
Under current mode, press
or
to modify the water setting temperature
whenever it is ON/OFF status.
5
.
2
How to set operation parameter
(
LED display show real time till HP
unit is power off. )
06
...
...