Heat Controller RADS-151G Owner'S Manual Download Page 8

Owner’s Manual 

Room Air Conditioner with R-410A

 

Heat Controller, Inc.

7

AIR CONDITIONER FEATURES(CONTINUED)

TO SELECT THE

OPERATING MODE:

Press the Mode
button.

Auto

Cool

Dry

Fan

Low

Auto

Med

High

Clean

Air

Fan

Mode

Follow

Me

Energy

Saver

On/Off

DO THIS:

To choose operating mode, press the Mode button.
Each time you press the button, a mode is selected
in a sequence that goes from Auto, Cool, Dry and
Fan. The indicator light beside will be illuminated

and remained on once the mode is selected.

NOTE:

To operate on Auto feature:

In this mode, the fan speed cannot be adjusted, it
starts automatically at a speed according to the
room temperature. If the room does not get too
warm, it will stay at Low speed.

To operate on Fan Only:

Use this function only when cooling is not desired,
such as for room air circulation or to exhaust stale
air(on some models). (Remember to open the vent
during this function, but keep it closed during

cooling for maximum cooling efficiency.) You can
choose any fan speed you prefer.
During this function, the display will show the actual
room temperature, not the set temperature as in the

cooling mode.

TO USE THE ENERGY

SAVER FEATURE:

Press the button

Auto

Cool

Dry

Fan

Low

Auto

Med

High

Clean

Air

Fan

Mode

Follow

Me

Energy

Saver

On/Off

DO THIS:

In this mode, the fan will continue to run for 3 minutes
after the compressor shuts off. The fan then cycles
on for 2 minutes at 10 minute intervals until the room
temperature is above the set temperature, at which
time the compressor turns back on and Cooling Stars.

NOTE:

Temp

Temp

Timer

Timer

On

Off

Sleep

Check

Filter

Timer

Auto

Cool

Dry

Fan

Low

Auto

Med

High

Clean

Air

SLEEP FEATURE:

Press Sleep
button

DO THIS:

In this mode the selected temperature will increase by
4 F(2 or 3 C) in the first hour after the mode is selected.
This new temperature will be maintained for another 6
hours before it returns to the originally selected
temperature. This ends the Sleep mode and the unit

will continue to operate as originally programmed.
The Sleep mode program can be cancelled at any
time during operation by again pressing the Sleep
button.

O

O

O

NOTE:

7

To operate on Dry mode:

In this mode, the air conditioner will generally
operate in the form of a dehumidifier. Since the
conditioned space is a closed or sealed area, some
degree of cooling will continue.

AIR CONDITIONER FEATURES(CONTINUED)

TO SELECT THE

OPERATING MODE:

Press the Mode
button.

Auto

Cool

Dry

Fan

Low

Auto

Med

High

Clean

Air

Fan

Mode

Follow

Me

Energy

Saver

On/Off

DO THIS:

To choose operating mode, press the Mode button.
Each time you press the button, a mode is selected
in a sequence that goes from Auto, Cool, Dry and
Fan. The indicator light beside will be illuminated

and remained on once the mode is selected.

NOTE:

To operate on Auto feature:

In this mode, the fan speed cannot be adjusted, it
starts automatically at a speed according to the
room temperature. If the room does not get too
warm, it will stay at Low speed.

To operate on Fan Only:

Use this function only when cooling is not desired,
such as for room air circulation or to exhaust stale
air(on some models). (Remember to open the vent
during this function, but keep it closed during

cooling for maximum cooling efficiency.) You can
choose any fan speed you prefer.
During this function, the display will show the actual
room temperature, not the set temperature as in the

cooling mode.

TO USE THE ENERGY

SAVER FEATURE:

Press the button

Auto

Cool

Dry

Fan

Low

Auto

Med

High

Clean

Air

Fan

Mode

Follow

Me

Energy

Saver

On/Off

DO THIS:

In this mode, the fan will continue to run for 3 minutes
after the compressor shuts off. The fan then cycles
on for 2 minutes at 10 minute intervals until the room
temperature is above the set temperature, at which
time the compressor turns back on and Cooling Stars.

NOTE:

Temp

Temp

Timer

Timer

On

Off

Sleep

Check

Filter

Timer

Auto

Cool

Dry

Fan

Low

Auto

Med

High

Clean

Air

SLEEP FEATURE:

Press Sleep
button

DO THIS:

In this mode the selected temperature will increase by
4 F(2 or 3 C) in the first hour after the mode is selected.
This new temperature will be maintained for another 6
hours before it returns to the originally selected
temperature. This ends the Sleep mode and the unit

will continue to operate as originally programmed.
The Sleep mode program can be cancelled at any
time during operation by again pressing the Sleep
button.

O

O

O

NOTE:

7

To operate on Dry mode:

In this mode, the air conditioner will generally
operate in the form of a dehumidifier. Since the
conditioned space is a closed or sealed area, some
degree of cooling will continue.

In the mode, the air conditioner will generally operate in 

the form of a dehumidifier to remove moisture from the air. 

Since the conditioned space is a closed or sealed area, 

some degree of cooling will continue.

starts.

each mode will be illuminated

AIR CONDITIONER FEATURES(CONTINUED)

TO SELECT THE

OPERATING MODE:

Press the Mode
button.

DO THIS:

To choose operating mode, press the Mode button.
Each time you press the button, a mode is selected
in a sequence that goes from Auto, Cool, Dry , Heat
(Cooling only models without) and Fan. The indicator

light beside will be illuminated and remained on

once the mode is selected.

NOTE:

To operate on Auto feature:

In this mode, the fan speed cannot be adjusted, it
starts automatically at a speed according to the
room temperature. If the room does not get too
warm, it will stay at Low speed.

To operate on Fan Only:

Use this function only when cooling is not desired,
such as for room air circulation or to exhaust stale
air(on some models). (Remember to open the vent
during this function, but keep it closed during

cooling for maximum cooling efficiency.) You can
choose any fan speed you prefer.
During this function, the display will show the actual
room temperature, not the set temperature as in the

cooling mode.

TO USE THE ENERGY

SAVER FEATURE:

Press the button

DO THIS:

In this mode, the fan will continue to run for 3 minutes
after the compressor shuts off. The fan then cycles
on for 2 minutes at 10 minute intervals until the room
temperature is above the set temperature, at which
time the compressor turns back on and cooling stars.

NOTE:

SLEEP FEATURE:

Press Sleep
button

DO THIS:

In this mode the selected temperature will increase by
2 degrees F 30 minutes after the mode is selected.
The temperature will then increase by another 2
degrees F after an additional 30 minutes. This new
temperature will be maintained for 7 hours before it

returns to the originally selected temperature. This
ends the Sleep mode and the unit will continue to
operate as originally programmed. The Sleep mode
program can be cancelled at any time during operation

by again pressing the Sleep button.

NOTE:

7

Energy

Saver

on

off

Timer

Auto

Fan

Cool

Dry

Mode

TEMP/TIMER

TEMP/TIMER

Heat

Energy

Saver

on

off

Timer

Auto

Fan

Cool

Dry

Mode

TEMP/TIMER

TEMP/TIMER

Sleep

Check

Filter

Follow

Me

Auto

On/off

Fan

High

Med

Low

on

off

Timer

TEMP/TIMER

TEMP/TIMER

Clean

Air

Clean

Air

To operate on Dry mode:

In this mode, the air conditioner will generally
operate in the form of a dehumidifier. Since the
conditioned space is a closed or sealed area, some
degree of cooling will continue.

AIR CONDITIONER FEATURES(CONTINUED)

TO SELECT THE

OPERATING MODE:

Press the Mode
button.

DO THIS:

To choose operating mode, press the Mode button.
Each time you press the button, a mode is selected
in a sequence that goes from Auto, Cool, Dry , Heat
(Cooling only models without) and Fan. The indicator

light beside will be illuminated and remained on

once the mode is selected.

NOTE:

To operate on Auto feature:

In this mode, the fan speed cannot be adjusted, it
starts automatically at a speed according to the
room temperature. If the room does not get too
warm, it will stay at Low speed.

To operate on Fan Only:

Use this function only when cooling is not desired,
such as for room air circulation or to exhaust stale
air(on some models). (Remember to open the vent
during this function, but keep it closed during

cooling for maximum cooling efficiency.) You can
choose any fan speed you prefer.
During this function, the display will show the actual
room temperature, not the set temperature as in the

cooling mode.

TO USE THE ENERGY

SAVER FEATURE:

Press the button

DO THIS:

In this mode, the fan will continue to run for 3 minutes
after the compressor shuts off. The fan then cycles
on for 2 minutes at 10 minute intervals until the room
temperature is above the set temperature, at which
time the compressor turns back on and cooling stars.

NOTE:

SLEEP FEATURE:

Press Sleep
button

DO THIS:

In this mode the selected temperature will increase by
2 degrees F 30 minutes after the mode is selected.
The temperature will then increase by another 2
degrees F after an additional 30 minutes. This new
temperature will be maintained for 7 hours before it

returns to the originally selected temperature. This
ends the Sleep mode and the unit will continue to
operate as originally programmed. The Sleep mode
program can be cancelled at any time during operation

by again pressing the Sleep button.

NOTE:

7

Energy

Saver

on

off

Timer

Auto

Fan

Cool

Dry

Mode

TEMP/TIMER

TEMP/TIMER

Heat

Energy

Saver

on

off

Timer

Auto

Fan

Cool

Dry

Mode

TEMP/TIMER

TEMP/TIMER

Sleep

Check

Filter

Follow

Me

Auto

On/off

Fan

High

Med

Low

on

off

Timer

TEMP/TIMER

TEMP/TIMER

Clean

Air

Clean

Air

To operate on Dry mode:

In this mode, the air conditioner will generally
operate in the form of a dehumidifier. Since the
conditioned space is a closed or sealed area, some
degree of cooling will continue.

Summary of Contents for RADS-151G

Page 1: ...RADS 151G RADS 183G RADS 253G Before using your air conditioner please read this manual carefully and keep it for future reference WINDOW WALL TYPE ROOM AIR CONDITIONER MULTI STEP SPEED ELECTRONIC CO...

Page 2: ...children should be supervised to ensure that they do not play with the air conditioner If the power cord is to be replaced replacement work shall be performed by authorised personnel only Installation...

Page 3: ...heating appliances Do not damage or use an unspecified power cord Do not direct airflow at room occupants only Always install circuit breaker and a dedicated power circuit Do not open the unit during...

Page 4: ...may cause failure It contains contaminants and could make you sick Always insert the filters securely Clean filter once every two weeks Do not drink water drained from air conditioner It may cause an...

Page 5: ...damaged it cannot be repaired It MUST be replaced by one NOTES obtained from the product manufacturer 4 Please refer to the section Operation of Current Device for details IMPORTANT SAFETY INSTRUCTION...

Page 6: ...tion may cause pinging or switching sounds Before you begin thoroughly familiarize yourself with the control panel and remote as shown below and all its functions then follow the symbol for the functi...

Page 7: ...r High Each time the button is pressed the fan speed mode is shifted NOTE 6 AIR CONDITIONER FEATURES CONTINUED TO TURN UNIT ON NOTE The following instructions represent the Unit Controls the same inst...

Page 8: ...idifier to remove moisture from the air Since the conditioned space is a closed or sealed area some degree of cooling will continue starts each mode will be illuminated AIR CONDITIONER FEATURES CONTIN...

Page 9: ...ees F after an additional 30 minutes This new temperature will be maintained for 7 hours before it returns to the originally selected temperature This ends the Sleep mode and the unit will continue to...

Page 10: ...again If the unit Filter button nate after 250 hours of operation To reset after cleaning the filter press the Check Filter button and the light will go off 8 Me Auto On off Fan High Med Low on off Ti...

Page 11: ...S CONTINUED that again 2 F 1 C between 60 F 16 C and 90 F 32 C ADDITIONAL THINGS YOU SHOULD KNOW Now that you have mastered the operating procedure here are more features in your control that you shou...

Page 12: ...removing storm window while room air conditioner is being installed Check your storm windows 4 check area outside of window for things such as shrubs trees or awnings Inside be sure furniture drapes o...

Page 13: ...il Level Socket wrenches Phillips Screwdriver 11 7 16 inch Locking screw and Flat washer for window panels 3 4 inch Long Hex head Screw Safety Lock 1 2 inch Long screw and Locknut 3 4 inch Long Flat H...

Page 14: ...Angle and Side Bracket 1 Attach foam gasket to top angle above holes as shown in Fig 6 2 Install top angle and side retainers to cabinet as shown in Fig 6 3 Assemble Window Filler Panels 1 Place cabi...

Page 15: ...et in place Stool Stool Angle 13 5 Install Support Bracket 1 Hold each support bracket flush against outside of sill and tight to bottom of cabinet as shown below Mark brackets at top level of sill an...

Page 16: ...2 Long Screws and Locknuts Locking Screw 7 Install Window Lock and Sash Seal 1 Trim sash seal to fit window width Insert into space between upper and lower sashes 2 Attach right angle safety lock as...

Page 17: ...the installation instructions Cover it with plastic or return it to the original carton Note Cabinet Cleaning Winter Storage 14 WARNING 104 F 40 C CARE AND CLEANING Clean your air conditioner occasio...

Page 18: ...Turn Control ON and set to desired setting O O O O Air conditioner cooling but room is too warm ice forming on cooling coil behind decorative front Outdoor temperature below 18 C 64 F To defrost the c...

Page 19: ...days Remote Sensing Deactivating Prematurely some models Remote control not located within range Place remote control within 20 feet 180 radius of the front of the unit Remote control signal obstructe...

Page 20: ...04 2009 11 2009...

Reviews: