Heat Controller RADS-151G Owner'S Manual Download Page 10

Owner’s Manual 

Room Air Conditioner with R-410A

 

Heat Controller, Inc.

9

AIR CONDITIONER FEATURES (CONTINUED)

AIR CONDITIONER FEATURES(CONTINUED)

FOLLOW ME FEATURE:

(on some models)

Light flashing

Auto

Cool

Dry

Fan

Low

Auto

Med

High

Clean

Air

Fan

Mode

Follow

Me

Energy

Saver

On/Off

NOTE:

To activate the Follow Me feature, point the remote
control towards the unit and press the Follow Me
button. T

If the unit

does not receive the Follow Me signal during any 7
minute interval, the unit will beep to indicate the
Follow Me mode has ended.
The actual temperature can be displayed at the unit
by pressing the Fan Only mode. When in the Cool

mode, the unit display indicates the set temperature.

he remote display is actual temperature

at its location. The remote control will send this
signal to the air conditioner every 3 minutes interval
until press the Follow Me button again.

This feature can be activated from the remote
control ONLY. The remote control serves as a
remote thermostat allowing for the precise
temperature control at its location.

ADDITIONAL THINGS YOU SHOULD KNOW

Now that you have mastered the operating procedure, here are more features in your control that
you should become familiar with.

The Cool circuit has an automatic 3 minute time delayed start if the unit is turned off and on
quickly. This prevents overheating of the compressor and possible circuit breaker tripping.

The fan will continue to run during this time.
The control will maintain any set temperature within 2 F/

, between 62

and 86

.

The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius.
To convert from one to the other, press and hold the Left and Right Temp/Timer buttons at the

same time, for 3 seconds.

O

O

O

O

O

O

1 C

F/17 C

F/30 C

Fresh Air Vent Control(on some models):

Figure 1 (VENT CLOSED)

Figure 2 (VENT OPEN)

The Fresh Air Vent allows the air conditioner to:
1. Recirculate inside air - Vent Closed (See Fig.1)
2. Draw fresh air into the room- Vent Open (see Fig.2)
3. Exchange air from the room and draws fresh air into

the room - Vent and Exhaust Open (see Fig.3)

Figure 3 (VENT & EXHAUST OPEN)

9

displays actual temperature

signal to the air conditioner in 3 minutes intervals

until the Follow Me button is pressed again. If the unit 

TIMER: AUTO START/

STOP FEATURE:

Press Timer
button

DO THIS:

AIR CONDITIONER FEATURES(CONTINUED)

First press the Timer button, the indicator light
besides word On illuminates. It indicates the Auto
Start program is initiated.
Press or hold the Up(

) or Down(

) to change

the Auto time by 0.5 hour increments, up to 10 hours,
then at 1 hour increments up to 24 hours. The control
will count down the time remaining until start.
The selected time will register in 5 second and the
system will automatically revert back to display the

previous temperature setting.
Turning the unit ON or OFF at any time will cancel

the Auto Start/Stop function.

NOTE:

CHECK FILTER FEATURE:

Press Check
Filter button

DO THIS:

This feature is a reminder to clean the Air Filter for
more efficient operation. The LED(light) will illumi-

nate after 250 hours of operation. To reset after
cleaning the filter, press the Check Filter button and
the light will go off.

NOTE:

8

Energy

Saver

on

off

Timer

Auto

Fan

Cool

Dry

Mode

TEMP/TIMER

TEMP/TIMER

Sleep

Check

Filter

Follow

Me

Auto

On/off

Fan

High

Med

Low

on

off

Timer

TEMP/TIMER

TEMP/TIMER

FOLLOW ME FEATURE:

(on some models)

Light flashing

NOTE:

To activate the Follow Me feature, point the remote
control towards the unit and press the Follow Me
button. T

If the unit

does not receive the Follow Me signal during any 7
minute interval, the unit will beep to indicate the
Follow Me mode has ended.
The actual temperature can be displayed at the unit
by pressing the Fan Only mode. When in the Cool

mode, the unit display indicates the set temperature.

he remote display is actual temperature

at its location. The remote control will send this
signal to the air conditioner every 3 minutes interval
until press the Follow Me button again.

This feature can be activated from the remote
control ONLY. The remote control serves as a
remote thermostat allowing for the precise
temperature control at its location.

Sleep

Check

Filter

Follow

Me

Auto

On/off

Fan

High

Med

Low

on

off

Timer

TEMP/TIMER

TEMP/TIMER

Clean

Air

ADDITIONAL THINGS YOU SHOULD KNOW

Now that you have mastered the operating procedure, here are more features in your control that
you should become familiar with.

The Cool circuit has an automatic 3 minute time delayed start if the unit is turned off and on
quickly. This prevents overheating of the compressor and possible circuit breaker tripping.

The fan will continue to run during this time.
The control will maintain any set temperature within 2 F, between 60 F and 90 F degrees.
The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius.

To convert from one to the other, press and hold the Up and Down Temp/Timer buttons at the

same time, for 3 seconds.

Fresh Air Vent Control(on some models):

Figure 1 (VENT CLOSED)

Figure 2 (VENT OPEN)

The Fresh Air Vent allows the air conditioner to:
1. Recirculate inside air - Vent Closed (See Fig.1)
2. Draw fresh air into the room- Vent Open (see Fig.2)
3. Exchange air from the room and draws fresh air into

the room - Vent and Exhaust Open (see Fig.3)

Figure 3
(VENT & EXHAUST OPEN)

9

Air Directional Louvers

The 4-way air directional louvers allow you to
direct the air flow Up or Down and Left or Right
throughout the room as needed. To adjust the
air directional louvers side-to -side, use the

center handles as you move it side-to-side.

Air Direction(4- way)

TO USE THE CLEAN AIR FEATURE:

(on some models)

Press the
button

DO THIS:

Energy

Saver

on

off

Timer

Auto

Fan

Cool

Dry

Mode

TEMP/TIMER

TEMP/TIMER

Clean

Air

Press the Clean Air button, the ion generator is
ener gized and will help to remove pollen and

impurities from the air, and trap them in the filter.

NOTE:

 energized

Summary of Contents for RADS-151G

Page 1: ...RADS 151G RADS 183G RADS 253G Before using your air conditioner please read this manual carefully and keep it for future reference WINDOW WALL TYPE ROOM AIR CONDITIONER MULTI STEP SPEED ELECTRONIC CO...

Page 2: ...children should be supervised to ensure that they do not play with the air conditioner If the power cord is to be replaced replacement work shall be performed by authorised personnel only Installation...

Page 3: ...heating appliances Do not damage or use an unspecified power cord Do not direct airflow at room occupants only Always install circuit breaker and a dedicated power circuit Do not open the unit during...

Page 4: ...may cause failure It contains contaminants and could make you sick Always insert the filters securely Clean filter once every two weeks Do not drink water drained from air conditioner It may cause an...

Page 5: ...damaged it cannot be repaired It MUST be replaced by one NOTES obtained from the product manufacturer 4 Please refer to the section Operation of Current Device for details IMPORTANT SAFETY INSTRUCTION...

Page 6: ...tion may cause pinging or switching sounds Before you begin thoroughly familiarize yourself with the control panel and remote as shown below and all its functions then follow the symbol for the functi...

Page 7: ...r High Each time the button is pressed the fan speed mode is shifted NOTE 6 AIR CONDITIONER FEATURES CONTINUED TO TURN UNIT ON NOTE The following instructions represent the Unit Controls the same inst...

Page 8: ...idifier to remove moisture from the air Since the conditioned space is a closed or sealed area some degree of cooling will continue starts each mode will be illuminated AIR CONDITIONER FEATURES CONTIN...

Page 9: ...ees F after an additional 30 minutes This new temperature will be maintained for 7 hours before it returns to the originally selected temperature This ends the Sleep mode and the unit will continue to...

Page 10: ...again If the unit Filter button nate after 250 hours of operation To reset after cleaning the filter press the Check Filter button and the light will go off 8 Me Auto On off Fan High Med Low on off Ti...

Page 11: ...S CONTINUED that again 2 F 1 C between 60 F 16 C and 90 F 32 C ADDITIONAL THINGS YOU SHOULD KNOW Now that you have mastered the operating procedure here are more features in your control that you shou...

Page 12: ...removing storm window while room air conditioner is being installed Check your storm windows 4 check area outside of window for things such as shrubs trees or awnings Inside be sure furniture drapes o...

Page 13: ...il Level Socket wrenches Phillips Screwdriver 11 7 16 inch Locking screw and Flat washer for window panels 3 4 inch Long Hex head Screw Safety Lock 1 2 inch Long screw and Locknut 3 4 inch Long Flat H...

Page 14: ...Angle and Side Bracket 1 Attach foam gasket to top angle above holes as shown in Fig 6 2 Install top angle and side retainers to cabinet as shown in Fig 6 3 Assemble Window Filler Panels 1 Place cabi...

Page 15: ...et in place Stool Stool Angle 13 5 Install Support Bracket 1 Hold each support bracket flush against outside of sill and tight to bottom of cabinet as shown below Mark brackets at top level of sill an...

Page 16: ...2 Long Screws and Locknuts Locking Screw 7 Install Window Lock and Sash Seal 1 Trim sash seal to fit window width Insert into space between upper and lower sashes 2 Attach right angle safety lock as...

Page 17: ...the installation instructions Cover it with plastic or return it to the original carton Note Cabinet Cleaning Winter Storage 14 WARNING 104 F 40 C CARE AND CLEANING Clean your air conditioner occasio...

Page 18: ...Turn Control ON and set to desired setting O O O O Air conditioner cooling but room is too warm ice forming on cooling coil behind decorative front Outdoor temperature below 18 C 64 F To defrost the c...

Page 19: ...days Remote Sensing Deactivating Prematurely some models Remote control not located within range Place remote control within 20 feet 180 radius of the front of the unit Remote control signal obstructe...

Page 20: ...04 2009 11 2009...