3

!

CAUTION

When the air filter is to be
removed, do not touch the
metal parts of the unit.

It may cause an injury.

Do not clean unit when
power is on as it may cause
fire and electric shock, it may
cause an injury.

Operation with windows
opened may cause wetting
of indoor and soaking of
household furniture.

When the unit is to be
cleaned, switch off, and turn
off the circuit breaker.

Stop operation and close
the window in storm or
hurricane.

Use caution when unpacking and
installing. Sharp edges could cause injury.

Do not clean the air
conditioner with water.

Water may enter the unit and
degrade the insulation. It may
cause an electric shock.

This could injure the pet or
plant.

It may cause electric shock
and damage.

Do not put a pet or house
plant where it will be
exposed to direct air flow.

Hold the plug by the head
of the power plug when
taking it out.

Ventilate the room well when
used together with a stove,
etc.

An oxygen shortage may occur.

Do not use this air conditioner to

preserve precision devices, food,

pets, plants, and art objects.

It may cause deterioration of

quality, etc.

It may cause failure of product

or fire.

Do not use for special
purposes.

Turn off the main power
switch when not sing the
unit for a long time.

u

If water enters the unit, turn the unit off at the power
outlet and switch off the circuit breaker. Isolate
supply by taking the power-plug out and contact a
qualified service technician.

3

!

!

!

!

!

!

!

It may cause failure of
appliance or accident.

Appearance may be
deteriorated due to change
of product color or
scratching of its surface.

Do not place obstacles
around air-inlets or inside
of air-outlet.

Do not use strong deter-
gent such as wax or
thinner but use a soft cloth.

If bracket is damaged, there
is concern of damage due to
falling of unit.

There is danger of fire or
electric shock.

Ensure that the installation bracket of
the outdoor appliance is not damaged
due to prolonged exposure.

Do not place heavy object on the
power cord and ensure that the cord
is not compressed.

Operation without filters may

cause failure.

It contains contaminants and

could make you sick.

Always insert the filters
securely. Clean filter once
every two weeks.

Do not drink water drained
from air conditioner.

!

!

• It may cause an injury due to sharp 

edges of components.

When the air filter is to be 

removed, do not touch the 

metal parts of the unit

• Water may enter the unit and degrade 

the insulation. It may cause an 

electric shock

Do not allow water to 

enter inside the unit 

during cleaning

•  An oxygen shortage may occur

•  May cause explosion, fire and/or 

burns

Ventilate the room well 

when used together with 

a gas stove or if there is 

a gas leak

•  Do not clean unit when power is on as 

it may cause fire and electric shock

When the unit is to be 

cleaned, switch off, and 

turn off the circuit breaker

•  Operation with windows opened may 

allow rain to enter inside and damage 

property

Stop operation and close 

the window in storm or 

hurricane

•  It may cause electric shock and 

damage

Hold the plug by the 

head of the power plug 

when taking it out

•  It may cause failure of product or fire

Turn off the main power 

switch when not using 

the unit for a long time

•  It may cause failure of appliance or 

accident

Do not place obstacles 

around air-inlets or inside 

of air-outlet

•  If bracket is damaged, there is concern 

of damage due to falling of unit.

Ensure that the instal-

lation bracket of the 

outdoor appliance is 

not damaged

•  Operation without filters may cause 

failure

•  Operation with dirty/clogged filters 

may cause failure

Always insert the filters 

securely. Clean filter 

once every two weeks

•  Appearance may be deteriorated 

due to change of product color or 

scratching of its surface

Do not use strong deter-

gents such as wax or thin-

ner; use a damp, soft cloth

•  There is danger of fire or electric 

shock

Do not place heavy ob-

ject on the power cord 

and ensure that the 

cord is not compressed

•  It contains contaminants and could 

make you sick

Do not drink water 

drained from air condi-

tioner

•  Sharp edges could cause injury

Use caution when un-

packing and installing

If water enters the unit, 

turn the unit off at the 

power outlet and switch 

off the circuit breaker. 

Isolate supply by taking 

power-plug out and con-

tact a qualified service 

technician

!

!

!

!

!

!

!

• Water may enter the unit and degrade 

the insulation. It may cause an 

electric shock

Summary of Contents for RADS-151G

Page 1: ...RADS 151G RADS 183G RADS 253G Before using your air conditioner please read this manual carefully and keep it for future reference WINDOW WALL TYPE ROOM AIR CONDITIONER MULTI STEP SPEED ELECTRONIC CO...

Page 2: ...children should be supervised to ensure that they do not play with the air conditioner If the power cord is to be replaced replacement work shall be performed by authorised personnel only Installation...

Page 3: ...heating appliances Do not damage or use an unspecified power cord Do not direct airflow at room occupants only Always install circuit breaker and a dedicated power circuit Do not open the unit during...

Page 4: ...may cause failure It contains contaminants and could make you sick Always insert the filters securely Clean filter once every two weeks Do not drink water drained from air conditioner It may cause an...

Page 5: ...damaged it cannot be repaired It MUST be replaced by one NOTES obtained from the product manufacturer 4 Please refer to the section Operation of Current Device for details IMPORTANT SAFETY INSTRUCTION...

Page 6: ...tion may cause pinging or switching sounds Before you begin thoroughly familiarize yourself with the control panel and remote as shown below and all its functions then follow the symbol for the functi...

Page 7: ...r High Each time the button is pressed the fan speed mode is shifted NOTE 6 AIR CONDITIONER FEATURES CONTINUED TO TURN UNIT ON NOTE The following instructions represent the Unit Controls the same inst...

Page 8: ...idifier to remove moisture from the air Since the conditioned space is a closed or sealed area some degree of cooling will continue starts each mode will be illuminated AIR CONDITIONER FEATURES CONTIN...

Page 9: ...ees F after an additional 30 minutes This new temperature will be maintained for 7 hours before it returns to the originally selected temperature This ends the Sleep mode and the unit will continue to...

Page 10: ...again If the unit Filter button nate after 250 hours of operation To reset after cleaning the filter press the Check Filter button and the light will go off 8 Me Auto On off Fan High Med Low on off Ti...

Page 11: ...S CONTINUED that again 2 F 1 C between 60 F 16 C and 90 F 32 C ADDITIONAL THINGS YOU SHOULD KNOW Now that you have mastered the operating procedure here are more features in your control that you shou...

Page 12: ...removing storm window while room air conditioner is being installed Check your storm windows 4 check area outside of window for things such as shrubs trees or awnings Inside be sure furniture drapes o...

Page 13: ...il Level Socket wrenches Phillips Screwdriver 11 7 16 inch Locking screw and Flat washer for window panels 3 4 inch Long Hex head Screw Safety Lock 1 2 inch Long screw and Locknut 3 4 inch Long Flat H...

Page 14: ...Angle and Side Bracket 1 Attach foam gasket to top angle above holes as shown in Fig 6 2 Install top angle and side retainers to cabinet as shown in Fig 6 3 Assemble Window Filler Panels 1 Place cabi...

Page 15: ...et in place Stool Stool Angle 13 5 Install Support Bracket 1 Hold each support bracket flush against outside of sill and tight to bottom of cabinet as shown below Mark brackets at top level of sill an...

Page 16: ...2 Long Screws and Locknuts Locking Screw 7 Install Window Lock and Sash Seal 1 Trim sash seal to fit window width Insert into space between upper and lower sashes 2 Attach right angle safety lock as...

Page 17: ...the installation instructions Cover it with plastic or return it to the original carton Note Cabinet Cleaning Winter Storage 14 WARNING 104 F 40 C CARE AND CLEANING Clean your air conditioner occasio...

Page 18: ...Turn Control ON and set to desired setting O O O O Air conditioner cooling but room is too warm ice forming on cooling coil behind decorative front Outdoor temperature below 18 C 64 F To defrost the c...

Page 19: ...days Remote Sensing Deactivating Prematurely some models Remote control not located within range Place remote control within 20 feet 180 radius of the front of the unit Remote control signal obstructe...

Page 20: ...04 2009 11 2009...

Reviews: