Heat Controller RADS-151G Owner'S Manual Download Page 14

Owner’s Manual 

Room Air Conditioner with R-410A

 

Heat Controller, Inc.

13

12

Window Mounting

1

Remove Chassis

1. Pull down front panel and remove filter.

(See Fig.1).

2. Lift front upwards and place to one side.

3. Locate the four front screws and remove.

These screws will be needed to re-install

the front later. (See Fig.2).

6. Remove shipping screws from top of unit and

also on the side by the base if installed.

7. Hold the cabinet while pulling on the base

handle, and carefully remove the unit.

8. Add two foam inserts to holes in top of cabinet

where shipping screws were removed from.

9. Your unit may come with internal packaging.

This packaging must be removed prior to
installing the air conditioner back into the

cabinet.(see Fig.5).

4. Pry away front from cabinet sides as shown in

Fig.3.

5. Gently lift front off unit and place to one side

(see Fig.4).

2

Install Top Angle and

Side Bracket

1. Attach foam gasket to top angle

above holes as shown in Fig.6.

2. Install top angle and side retainers

to cabinet as shown in Fig.6.

3

Assemble W indow Filler Panels

1. Place cabinet on floor, a bench, or

a table.

2. Slide

section of window filler panel

into side retainer on the side of the
cabinet (see Fig.7). Do both sides.

I

,

,

,

,

Plastic
Frame

Window Filler
Panel

Side Retainer

Fig.7

Fig.6

5 1

6

lon

g

hex

-he

ad

/

1. Pull down front grille and remove filter  

(see Fig. 1).

2. Lift front grille upwards to remove.

3. Locate the four front screws and remove. 

These screws will be needed to reinstall the 

front grille later. (See Fig. 2).

4. Pry away front panel from cabinet sides as 

shown in Fig. 3. 

5. Gently lift front panel off unit to remove (see 

Fig. 4).

6. Remove shipping screws from top of unit and 

also on the side by the base (if installed).

9. Your unit may come with internal packaging. 

This packaging must be removed prior to re-

installing the air conditioner into the cabinet 

(see Fig. 5).

2. Install top angle and side retainers 

onto cabinet as shown in Fig. 6.

Summary of Contents for RADS-151G

Page 1: ...RADS 151G RADS 183G RADS 253G Before using your air conditioner please read this manual carefully and keep it for future reference WINDOW WALL TYPE ROOM AIR CONDITIONER MULTI STEP SPEED ELECTRONIC CO...

Page 2: ...children should be supervised to ensure that they do not play with the air conditioner If the power cord is to be replaced replacement work shall be performed by authorised personnel only Installation...

Page 3: ...heating appliances Do not damage or use an unspecified power cord Do not direct airflow at room occupants only Always install circuit breaker and a dedicated power circuit Do not open the unit during...

Page 4: ...may cause failure It contains contaminants and could make you sick Always insert the filters securely Clean filter once every two weeks Do not drink water drained from air conditioner It may cause an...

Page 5: ...damaged it cannot be repaired It MUST be replaced by one NOTES obtained from the product manufacturer 4 Please refer to the section Operation of Current Device for details IMPORTANT SAFETY INSTRUCTION...

Page 6: ...tion may cause pinging or switching sounds Before you begin thoroughly familiarize yourself with the control panel and remote as shown below and all its functions then follow the symbol for the functi...

Page 7: ...r High Each time the button is pressed the fan speed mode is shifted NOTE 6 AIR CONDITIONER FEATURES CONTINUED TO TURN UNIT ON NOTE The following instructions represent the Unit Controls the same inst...

Page 8: ...idifier to remove moisture from the air Since the conditioned space is a closed or sealed area some degree of cooling will continue starts each mode will be illuminated AIR CONDITIONER FEATURES CONTIN...

Page 9: ...ees F after an additional 30 minutes This new temperature will be maintained for 7 hours before it returns to the originally selected temperature This ends the Sleep mode and the unit will continue to...

Page 10: ...again If the unit Filter button nate after 250 hours of operation To reset after cleaning the filter press the Check Filter button and the light will go off 8 Me Auto On off Fan High Med Low on off Ti...

Page 11: ...S CONTINUED that again 2 F 1 C between 60 F 16 C and 90 F 32 C ADDITIONAL THINGS YOU SHOULD KNOW Now that you have mastered the operating procedure here are more features in your control that you shou...

Page 12: ...removing storm window while room air conditioner is being installed Check your storm windows 4 check area outside of window for things such as shrubs trees or awnings Inside be sure furniture drapes o...

Page 13: ...il Level Socket wrenches Phillips Screwdriver 11 7 16 inch Locking screw and Flat washer for window panels 3 4 inch Long Hex head Screw Safety Lock 1 2 inch Long screw and Locknut 3 4 inch Long Flat H...

Page 14: ...Angle and Side Bracket 1 Attach foam gasket to top angle above holes as shown in Fig 6 2 Install top angle and side retainers to cabinet as shown in Fig 6 3 Assemble Window Filler Panels 1 Place cabi...

Page 15: ...et in place Stool Stool Angle 13 5 Install Support Bracket 1 Hold each support bracket flush against outside of sill and tight to bottom of cabinet as shown below Mark brackets at top level of sill an...

Page 16: ...2 Long Screws and Locknuts Locking Screw 7 Install Window Lock and Sash Seal 1 Trim sash seal to fit window width Insert into space between upper and lower sashes 2 Attach right angle safety lock as...

Page 17: ...the installation instructions Cover it with plastic or return it to the original carton Note Cabinet Cleaning Winter Storage 14 WARNING 104 F 40 C CARE AND CLEANING Clean your air conditioner occasio...

Page 18: ...Turn Control ON and set to desired setting O O O O Air conditioner cooling but room is too warm ice forming on cooling coil behind decorative front Outdoor temperature below 18 C 64 F To defrost the c...

Page 19: ...days Remote Sensing Deactivating Prematurely some models Remote control not located within range Place remote control within 20 feet 180 radius of the front of the unit Remote control signal obstructe...

Page 20: ...04 2009 11 2009...

Reviews: