Heat & Glo • TIARAI-BK-IPI, TIARAI-BR-IPI, TIARAI-CES-IPI Installation Manual • 2342-980_R8 • 11/14
29
EXHAUST VENT PIPE
INLET AIR VENT PIPE
Coaxial to Colinear Venting
the coaxial to colinear adapter (dV-46dVa-gcl) is
approved for installations into solid fuel masonry or factory
built fireplaces that have been installed in accordance with
the National, Provincial, State and local building codes.
Figure 4.31 Coaxial/Colinear Appliance Connector
WARNING! Risk of Fire!
Coaxial to colinear venting
configuration may only be used in existing non-combustible
chimney. Installation in any other venting application could
cause fire.
WARNING! Risk of Fire, Explosion or Asphyxiation!
Do
NOT connect this gas appliance to a chimney flue serving a
separate solid fuel or gas burning appliance.
• May impair safe operation of this appliance or other
appliances connected to the flue.
• Vent this appliance directly outside.
• Use separate vent system for this appliance.