Heat & Glo • TIARAI-BK-IPI, TIARAI-BR-IPI, TIARAI-CES-IPI Installation Manual • 2342-980_R8 • 11/14
22
Figure 4.17
Three Elbows
INSTALLED
HORIZONTALLY
H
3
H
1
H
2
V
1
3 Elbows to Max. Horizontal
V
1
Minimum
H
1
Minimum
H
1
Maximum
H
total
2 ft.
610 mm
6 in.
152 mm
14 in.
357 mm
3 ft.
914 mm
4 ft.
1.2 m
6 in.
152 mm
14 in.
357 mm
4 ft., 3 in.
1.3 m
6 ft.
1.8 m
6 in.
152 mm
14 in.
357 mm
5 ft., 6 in.
1.7 m
8 ft.
2.4 m
6 in.
152 mm
14 in.
357 mm
6 ft., 9 in.
2.1 m
10 ft.
3.1 m
6 in.
152 mm
14 in.
357 mm
8 ft.
2.4 m
12 ft.
3.7 m
6 in.
152 mm
14 in.
357 mm
7 ft., 2 in.
2.2 m
16 ft.
4.9 m
6 in.
152 mm
14 in.
357 mm
5 ft., 3 in.
1.6 m
20 ft.
6.1 m
6 in.
152 mm
14 in.
357 mm
3 ft., 4 in.
1.0 m
24 ft.
7.3 m
6 in.
152 mm
14 in.
357 mm
1 ft., 6 in.
457 mm
Note:
a derating orifice is required with this
application and is included in the Rear Vent Kit.