27
Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. C • 2/11
Figure 8.12 Optional SLP venting confi guration - Horizontal Termination
90°
ELBOW
Note: Use caulking sealant at
connection points to ducts. Sealant
must have a minimum exposure
rating of 1200° F (649° C) or higher.
MINIMUM
10 FT. (3,05 m)
2222-078
VENT COVER FIRESTOP
See Figure 8.14 for use
when penetrating a
non-combustible wall.
DV-46DVA-GK
COLINEAR TO COAXIAL ADAPTER
(50 mm CLEARANCE AROUND ADAPTER TO
COMBUSTIBLE MATERIAL)
MINIMUM
3 FT. (91,44 cm)
MAXIMUM
2 FT
. (609
mm)
SLP-TRAP2
MUST ADHERE TO
MINIMUM PIPE
CLEARANCES
MUST ADHERE TO
MINIMUM PIPE
CLEARANCES
NOTE: Any 3 IN. (76mm) section
of flex pipe must be enclosed to
existing fireplace flue indouble
lined flue to comply with
AS2918:2001 and the building
code of Australia.
MAXIMUM
40 FT (12m)
Note:
The header can only be installed in an existing masonry
chase or equivalent non-combustible enclosure. Clearances
around and above pipe must be adhered to.
Note:
Adhere to AS5601 plumbers code for minimum clearances
for termination of balanced fl ue appliances.