Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. C • 2/11
22
Figure 8.2
CUT AND BEND
FLASHING AS NEEDED
TO FIT CHIMNEY
SEALANT
ADHESIVE
• Trim chimney top plate to minimize excess overhang or
bend over fl ue tile (see Figure 8.2).
• Place 3/8 inch bead of 300º F silicone on fl ue tile top.
See Figure 8.2.
D. Placing, Securing and Leveling the
Appliance
• Install insert (without surround attached) into existing
fi replace while pulling collar slide plate forward.
• Install gas line into hole provided on insert side.
• If applicable install remote control wires into insert side.
See individual door instrucitons for reference.
• Secure collar slide plate to appliance by placing locking
handle into position with locking tabs (see Figure 8.1)
and secure with #8 screw.
WARNING! Risk of Fire!
Only an approved Hearth &
Home Technologies surround may be used to cover inte-
gral grills on solid fuel burning fi replaces. No other com-
ponents such as shrouds, sheetmetal plates, etc., may be
used to seal off vents.
WARNING! Risk of Fire!
Failure to position the parts in
accordance with these diagrams or failure to use only
parts specifi cally approved with this appliance may result
in property damage or personal injury.
WARNING! Risk of Explosion/Combustion Fumes!
Connect vent sections per installation instructions.
• Connect exhaust vent pipe ONLY to exhaust starting
collar and termination cap center collar.
• Connect inlet air vent ONLY to inlet air collar on appliance
and the termination cap inlet air collar.
•
DO NOT
allow vent to sag below connection point to
appliance.
Figure 8.3 Staggered Termination Caps
• Level the appliance from side to side and front to back. If
necessary, use the leveling legs included with the manual
bag to set each corner of the base.
• Position any excess fl exible vent pipe back up into
chimney without sagging. Twist and push flex vent
together to shorten.
• Install fiberglass insulation pieces to back face of
surround.
• Attach surround. Follow instructions for surround
installation included with the front.
• Push insert into the opening so that it tightly overlaps the
fi replace opening.
Gas, Wood or Fuel Oil
Termination Cap
B
Gas
Termination
Cap **
A*
*
If using decorative cap cover(s), this distance may need to be
increased. Refer to the installation instructions supplied with the
decorative cap cover.
**
In a staggered installation with both gas and wood terminations, the
wood termination cap must be higher than the gas termination cap.
B
A
152 mm (minimum) up to 508 mm
457 mm minimum
508 mm and over
0 mm minimum