background image

2

35035 Rev D

07/03

STS-42 INSTALLATION INSTRUCTIONS

CAUTION:

Do not expose the fireplace to the elements (i.e. rain, etc.) and keep the fireplace dry at all times. Wet insula-

tion will produce an odor when the fireplace is used.

TABLE OF CONTENTS

A.  Listings and Code Approvals ...................................................................................................................... 3

B. Description of the Fireplace System ............................................................................................................ 3

C. Fireplace System Components ................................................................................................................... 4

D. Pre-Installation Preparation ......................................................................................................................... 8

E. Chimney Requirements ............................................................................................................................. 10

F. Installation of Fireplace ............................................................................................................................. 12

G. Operating Instructions ............................................................................................................................... 21

H. Maintenance Instructions .......................................................................................................................... 25

Index ......................................................................................................................................................... 27

Warranty ................................................................................................................................................... 28

WARNING!

This appliance is tested and listed for use only with the optional accessories listed in these instructions. Use

of optional accessories not specifically tested for this appliance could void the warranty and/or result in a

safety hazard.

Safety Precautions

1.

Please read these installation instructions completely before beginning installation procedures. Failure to follow them

could cause a fireplace malfunction resulting in serious injury and/or property damage.

2.

Always check your local building codes prior to installation. The installation must comply with all local, regional, state

and national codes and regulations.

3.

An  adequate  supply  of  replacement  combustion  air  from  outside  the  house  must  be  available  to  the  fire  for  the

fireplace to operate properly. To achieve this, the use of the optional outside air kit is highly recommended.

In the event the home is unusually tightly sealed, the optional combustion air kit may not provide all the air required to

support combustion. Hearth & Home Technologies is not responsible for any smoking or related problems that may

result from the lack of adequate combustion air. It is the responsibility of the builder/contractor to ensure that adequate

combustion air has been provided for the fireplace.

4.

The fireplace must be installed with the Hearth & Home Technologies SL Series Chimney System.
The chimney system must always terminate outside the building. Be sure to follow all chimney specifications given in

these installation instructions.

5. NEVER

 leave children unattended when there is a fire burning in the fireplace.

6.

This fireplace is built for solid fuel only. 

NEVER

 use gasoline, gasoline type lantern fuel, kerosene, charcoal light fluid,

or similar liquids in this fireplace. Keep any flammable liquids a safe distance from the fireplace.

7. DO NOT

 use chimney cleaners or flame colorants in your fireplace.

8.

The flue damper must be open at all times when the fireplace is in use.

9.

While servicing this fireplace, always shut off any electricity or gas to the fireplace. This will prevent possible electric

shock or burns. Also, make sure the fireplace is completely cooled before servicing.

10.

To ensure a safe fireplace system and to prevent the build up of soot and creosote, inspect and clean the fireplace

and chimney prior to use and periodically during the burning season. See “Maintenance Instructions” in this manual

for cleaning instructions.

Summary of Contents for STS-42

Page 1: ...ge Refer to this manual For assistance or additional information consult a qualified installer service agency or the gas supplier INSTALLATION OPERATING INSTRUCTIONS STS 42 OUTDOOR WOODBURNING FIREPLA...

Page 2: ...ended In the event the home is unusually tightly sealed the optional combustion air kit may not provide all the air required to support combustion Hearth Home Technologies is not responsible for any s...

Page 3: ...he illustrations and diagrams used throughout these installations instructions are not drawn to scale B DESCRIPTION OF THE FIREPLACE SYSTEM Figure 1 Typical Fireplace System A LISTINGS AND CODE APPROV...

Page 4: ...a l B w e i V r a e l C s r o o D s s a l G d l o f i B B 2 4 8 1 M D s s a r B d e h s i l o P w e i V r a e l C s r o o D s s a l G d l o f i B S 2 4 8 1 M D l e e t S s s e l n i a t S w e i V r a...

Page 5: ...z i l i b a t S y e n m i h C 0 3 1 1 L S 0 3 n r u t e R t e s f f O y e n m i h C 8 3 5 S F t h g i a r t S p o t s e r i F 0 4 5 S F 0 3 p o t s e r i F 0 1 S A 4 2 d l e i h S n o i t a l u s n I...

Page 6: ...n e l h t g n e l e v i t c e f f E s a h t i r e t f a t r a p y e n m i h c r e h t o n a o t d e p p a n s n e e b SL11 Chimney Stabilizer SL1130 Offset Return RF570 Roof Flashing Flat to 6 12 Pit...

Page 7: ...v D 7 STS 42 INSTALLATION INSTRUCTIONS LDS33 3 x 3 LDS46 4 x 6 Decorative Shroud TR11 Round Termination Cap TR11T Round Telescoping Termination Cap ST1175 Square Termination Cap CT56 Chase Top CAK5A C...

Page 8: ...lt if it is installed inside of the structure Figure 2 shows two typical installations Figures 3 and 4 show two typical installations assuming an outside air kit is being used Therefore an allowance m...

Page 9: ...x 423 8 tall The finished cavity depth must be no less than 241 8 Figure 5 shows a typical framing using 2 x 4 lumber of the fireplace assuming combustible materials are used All required clearances...

Page 10: ...far the chimney needs to be shifted to enable it to avoid the overhead obstacle See Figure 7 dimension A to determine chimney sections required to achieve the needed shift 2 After determining the offs...

Page 11: ...e installation d Determine the number of firestop spacers stabi lizers roof flashing etc required to complete the fireplace installation 2 Chimney Height Requirements above roof line a Major building...

Page 12: ...instructions for framing on pages 8 and 9 Slide the fireplace into position Be sure to provide the minimum air clearance at the sides and back of the fireplace assembly 2 Placing the Protective Metal...

Page 13: ...ntil the top section meets the stop bead on the lower section The inner flue is placed to the inside of the flue section below it The outer casing is placed outside the outer casing of the chimney sec...

Page 14: ...ulation shield should be installed when there is a possibility of insulation coming into contact with the factory built chimney system The insulation shield is installed by positioning it over the ver...

Page 15: ...ppermost top section of pipe must extend 6 above the top of the chase collar to allow installation of the storm collar and termination cap See Figure 14 Figure 14 Installing a TR11 Round Termination C...

Page 16: ...a standard feature with this fireplace and is required for safe operation Installation must be done at the time of initial construction The cooling air inlet tubes must be a minimum of 72 above the ba...

Page 17: ...in this specific model fireplace Unless the unvented gas log heater is tested and listed for use in this factory built fireplace a fire hazard may be created that can result in a structure fire 13 Ga...

Page 18: ...st be installed with all fireplaces to protect the combustible floor in front of the fireplace from both radiant heat and sparks The construction of and materials used for a hearth extension are shown...

Page 19: ...te slate glass or plasters or any combination thereof c Noncombustible Sealant Material Sealants which will not ignite and burn General Electric RTV103 Black or equivalent Rutland Inc Fireplace Mortar...

Page 20: ...fire WARNING Detailed instructions for installation of the chase top storm collar and termination cap are packaged with these parts To avoid danger of fire all instructions must be strictly followed i...

Page 21: ...n Fireplaces as well as other woodburning appliances have been used safely for many years It has been our experience that most problems are caused by improper installation and operation of the firepla...

Page 22: ...ogies glass doors may be used See Figure 24 for proper glass door operation 4 Grate The factory installed integral grate must be used to hold the logs from falling out of an open fireplace and to allo...

Page 23: ...s on the quality of the firewood you use All seasoned wood regardless of species contains about 8 000 BTU s per pound and hardwoods have a greater density than soft woods A piece of hardwood will cont...

Page 24: ...e fireplace expansion and contraction will cause minor cracking of the refractory This is normal unavoidable and will not affect the perfor mance of the fireplace If the cracks become large enough tha...

Page 25: ...If creosote has accumulated it should be removed to reduce the risk of a chimney fire 3 Chimney Cleaning If you do detect a buildup of creosote contact a qualified chimney sweep or clean it yourself...

Page 26: ...26 35035 Rev D 07 03 STS 42 INSTALLATION INSTRUCTIONS Homeowner s Notes...

Page 27: ...3 Flue 21 Framing 9 Freestanding Installation 8 Fuel 23 G Gas Codes 17 21 Gas Log Lighter Provisions 17 General Information 21 Glass Doors 19 Grate 22 H Hearth Extension 18 Positioning 19 I Installati...

Page 28: ...4 During the first six 6 months after installation HHT shall at its option replace or repair the glass doors and any electrical components if operation is faulty This does not include glass panels bro...