Heat & Glo • PRIMO48, PRIMO48ST, PRIMO60, PRIMO60ST, PRIMO72, PRIMO72ST Owner’s Manual • 2310-971 Rev. G • 9/15
12
G. Appliance Break-In
Initial Break-in Procedure
• The fireplace should be run three to four hours
continuously on high.
• Turn the
fi
replace off and allow it to completely cool.
• Have a quali
fi
ed service technician remove barrier glass
and
fi
rebox glass. See Section 4.
• Have a quali
fi
ed service technician clean
fi
rebox glass.
See Section 4.
• Have a quali
fi
ed service technician replace the barrier
glass and
fi
rebox glass. Run appliance continuously on
high an additional 12 hours.
This cures the materials used to manufacture the
fi
re-
place.
NOTICE! Open windows for air circulation during
fi
re-
place break-in.
• Some people may be sensitive to smoke and odors.
• Smoke detectors may activate.
H. Heat Management
Burn Rate
The PRIMO models have a variable burn rate which is
controlled by the remote control. Therefore the
fl
ame
height is adjustable.
The
fl
ame height may be adjusted as desired by locating
the
fl
ame option on the remote control and adjusting up or
down to desired
fl
ame height.
The PRIMO requires a PowerFlow™ Heat Management
System. It may be either a HEAT-ZONE-PRIMO, which
diverts heat into an adjacent room, and/or a HEAT-OUT-
PRIMO which will divert heat outside the home/building.
HEAT-ZONE-PRIMO
Use the optional HEAT-ZONE-PRIMO systems for heat
management with the PRIMO. The HEAT-ZONE-PRIMO
must be installed by a quali
fi
ed service technician at the
time of appliance installation. The PRIMO will not function
properly unless the HEAT-ZONE-PRIMO systems are
properly installed. HEAT-ZONE-PRIMO systems are
designed to keep the barrier glass from overheating and
to keep the controls and gas train cool.
HEAT-OUT-PRIMO
Use the optional HEAT-OUT-PRIMO for heat manage-
ment with the PRIMO. The HEAT-OUT-PRIMO allows the
heat to be removed from the home while the
fi
replace is in
operation. This feature is useful when heat is not needed,
I. Operation During A Power Outage
The PRIMO model requires electrical power in order to
operate the required heat management system and power
vent. If electrical power service is interrupted during
operation of this model, the appliance will not operate.
Battery power is not an option on the PRIMO.
When power is restored, press the RESET switch located
on the left side of the transition media tray. See Figure 3.5.
WARNING! Risk of Fire!
Either the HEAT-ZONE-PRIMO
or the HEAT-OUT-PRIMO PowerFlow™ Heat Manage-
ment System must remain ON during operation of the ap-
pliance. Overheating will occur. Appliance will shut down.
but ambiance is desired. The optional heat management
system is designed to keep the barrier glass from over-
heating and to keep the controls and gas train cool. It
must be installed by a quali
fi
ed service technician at the
time of appliance installation.