13
Heat & Glo • PRIMO48, PRIMO48ST, PRIMO60, PRIMO60ST, PRIMO72, PRIMO72ST Owner’s Manual • 2310-971 Rev. G • 9/15
Figure 3.4 Control Module
Control Module Operation
1. The control module has an ON/OFF/REMOTE selector
switch that must be set. See Figure 3.4.
OFF Position: Appliance will ignore all power inputs and
will not respond to any commands from the remote. The
unit should be in the OFF position during installation,
service, fuel conversion, and in the event that the control
goes into LOCK-OUT mode as a result of an error code.
ON Position: Appliance will ignite and run continuously
in the HI
fl
ame setting, with no adjustment in
fl
ame
output. This mode of operation is primarily used for
initial installation .
REMOTE Position: Appliance will initiate commands
from an optional wired wall switch and/or the wireless
remote (RC300).
2. The control module has safety feature that automatically
shuts down the
fi
replace after 9 hours of continuous
operation without receiving a command from the RC300
remote.
2.
Module Reset
This module may lock-out under certain conditions.
When this occurs, the appliance will not ignite or
respond to commands. The module will go into
lock-out mode by emitting three audible beeps, then
continuously displaying a RED/GREEN error code at
its status indicator LED. The module can be reset with
the switch.
Nine Hour Safety Shutdown Feature
The appliance has a safety feature that automatically
shuts down the
fi
replace after nine hours of continuous
operation without receiving a command from the
remote.
J. Detailed Component Operating Instruc-
tions
Appliance ON/OFF
Use the IntelliFire™ Plus Remote Control to control the
ON/OFF function of the appliance. Follow instructions
included with the installed control.
IntelliFire™ Plus
NG/LP GAS-TYPE
SELECTOR SWITCH
FLAME HI/LOW
SWITCH
STATUS
INDICATOR LED
MODULE
Figure 3.5 Reset Switch Location - Bottom Left
RESET SWITCH
Reset Switch Operation
1.
Appliance Reset Switch (Module Reset)
The PRIMO has an appliance reset switch located on
the bottom left side of the appliance. See Figure 3.5.
This switch may be turned to OFF if
fi
replace will not
be used for an extended period of time.
NOTE:
Once the appliance is installed, access to the
module is limited or not available, depending on the
fi
nishing
method. Call a quali
fi
ed service technician for assistance.
• Locate the module selector switch. (See Figure 3.4).
• Set the module selector switch to the OFF position.
• Set the module selector switch to ON or REMOTE
position.
• Start the appliance.
WARNING! Risk of Explosion! DO NOT
press the mod-
ule reset switch more than one time within a
fi
ve minute
time period. Gas could accumulate in
fi
rebox. Call a quali-
fi
ed service technician.
NOTE:
Once the appliance is installed, access to the
module is limited or not available, depending on the
fi
nishing
method. Call a quali
fi
ed service technician for assistance.
• Use a small,
fl
at object to access and press the
RESET switch. When the appliance has started,
fl
ip
the reset switch back to its original position.