background image

480-1081                                                                                                        28                                                                                                              4-03

North Star 

EPA Certified Fireplace

6. Care and Cleaning of Glass

Your  fireplace  is  equipped  with  ceramic  super  heat-

resistant glass, which can only be broken by impact or 

misuse.  Do not slam doors or impact the glass.  When 

closing  doors,  make  sure  that  logs  do  not  protrude 

against  the  glass.   Clean  glass  with  a  nonabrasive 

glass  cleaner,  such  as Windex.   Abrasive  cleaners 

may scratch and cause glass to crack.  Inspect glass 

regularly.   If  you  find  a  crack  or  break,  immediately 

put the fire out and return the door to your dealer for 

replacement of glass before further use.

7. Care and Cleaning of Plated Surfaces

Clean 24 karat gold-plated surfaces with vinegar or a 

glass cleaner before lighting your first fire.

WARNING!

When the appliance is equipped with a 24 karat gold-plated 

door, you must clean all the fingerprints and oils from the 

gold surface before firing the appliance for the first time.  

Use a glass cleaner or vinegar and towel to remove the 

oils.   If  not  cleaned  properly  before  lighting  your  first 

fire, the oils can cause permanent markings on the gold 

plating.  After the gold plating

 i

is cured, the oils will not 

affect the finish and little maintenance is required:  just 

wipe clean as needed.

CAUTION:

Do not use polishes with abrasives as it will scratch 

the surface.

IMPORTANT! 

REMOVE  ALL  LABELS  FROM  GLASS  BEFORE 

LIGHTING THE FIRST FIRE IN YOUR FIREPLACE.

IMPORTANT! 

Replace with 5mm ceramic glass only

8. Glass Replacement

1.     Ensure  that  the  fire  is  out  and  the  appliance  is 

cool to the touch.

2.     Protect  a  table  or  counter  top  with  padding  or 

towels.

3.     Remove door with broken glass from the appliance 

by lifting door up and off of the hinges.

4.     Lay door face down on a table or counter making 

sure  handle  and  handle  attachment  knob  hang 

over  the edge of the table top so door lays flat, 

on a soft surface. 

 

5.     Remove  the  screws  from  each  glass  tab  (5  on 

each door) using a #2 Phillips Head screwdriver.

       

HINT

:   Soak  screws  in  penetrating  oil  for  easy 

removal.

6.     Remove the glass.

7.     Use only 5mm ceramic Glass, Part GLA-480.

8.     Position the glass with edges evenly overlapping 

the opening in the front door.

9.     Replace the glass tabs.  Be careful not to cross 

thread the screws.

10.   Tighten  each  tab  just  a  few  turns  until  each  is 

secured.   Then  continue  to  tighten  each  tab 

alternately, a few turns at a time, until the glass 

panel is tightened snugly, but not over tightened.

11.   Replace the door on the appliance.

12.   After  the  first  burn,  recheck  the  tighness  of  the 

screws.

Summary of Contents for BIR50

Page 1: ...ease read entire manual before you install and use your fireplace O T L Tested and Listed by Beaverton Oregon USA OMNI Test Laboratories Inc C Hearth Home Technologies 20802 Kensington Blvd Lakeville...

Page 2: ...shock Also make sure the fireplace is completely cooled before Installation and Draft Considerations 4 A Listings and Code Approvals 3 B Description of the Fireplace System 3 C Fireplace Dimesions Cl...

Page 3: ...F THE FIREPLACE SYSTEM A LISTINGS AND CODE APPROVALS This fireplace system has been tested and listed in accordance with UL127 and ULC S610 M87 standards and has been listed by OMNI Test Laboratories...

Page 4: ...ot Recommended Recommended Location Location NOT Recommended Cathedral Ceiling Construction 2nd Floor Balcony 1st Floor Multi level Roofs The outside air kit is installed on the right hand side of the...

Page 5: ...and 8 203mm to either side of the fuel opening must be insulated with non combustible floor protection with a minimum thickness of 1 25mm and k value 0 43 2 Fireplace is flush on the floor and Hearth...

Page 6: ...36 long SL348 Chimney Section 48 long SL3 Chimney Stabilizer SL315 Chimney Offset Return 15 SL330 Chimney Offset Return 30 FS338 Firestop Straight FS339 Firestop 15 FS340 Firestop 30 AS8 Straight Att...

Page 7: ...restop Spacer 24 A 8 101 2 Inside Diameter 8 Outside Diameter 101 2 A B 14 1 2 10 1 2 2 10 1 2 JB877 Joint Band 12 24 5 8 27 3 8 12 31 24 5 8 SL306 6 4 3 4 SL312 12 10 3 4 SL318 18 16 3 4 SL324 24 22...

Page 8: ...e Termination Cap CT35 Chase Top CAK4A Chimney Air Kit 15 3 4 TR342 TERMINATION CAP TOP OF UPPERMOST CHIMNEY SECTION 14 1 2 MAX DISTANCE CHASE TOP 23 14 3 4 17 3 4 8 Flue 10 1 2 Outer 16 1 2 13 1 4 22...

Page 9: ...to you when choosing a location for your fireplace This fireplace may be used as a room divider installed along a wall across a corner or used in an exterior chase See Figure 9A Locating the fireplace...

Page 10: ...ystem and chimney components have been tested to provide flexibility in construction The following figures are the minimum distances from the base of the fireplace 2 Framing the Fireplace 1 Min overal...

Page 11: ...icular chimney parts 5 Whenever the chimney penetrates a floor ceiling a firestop spacer must be installed 6 The effective height of the fireplace assembly is measured from the base of fireplace to to...

Page 12: ...t passes through the roof See Figure 12A b These chimney heights are necessary in the interest of safety but do not ensure smoke free operation Trees buildings adjoining roof lines adverse wind condit...

Page 13: ...strips measuring approximately 23 x 4 These strips are used to provide added protection where the fireplace and the hearth extension meet Slide each metal strip 2 under the front edge of the fireplac...

Page 14: ...dimension lumber used in the ceiling joists Install the firestop spacer These firestop spacers are designed to provide the minimum 2 air space required around the chimney In all situations the firest...

Page 15: ...y of the mobile home floor wall and ceiling roof must be maintaned i e Do not cut through floor joist wall stud ceiling truss etc WARNING NEVER DRAW COMBUSTION AIR FROM A WALL FLOOR OR CEILING CAVITY...

Page 16: ...t gravity from pulling the chimney sections apart the returns and the chimney stabilizers have straps for securing these parts to joists or rafters See Figure 16B 11 Marking the Exit Point of the Roof...

Page 17: ...ks The construction of and materials used for a hearth extension are shown in Figures 17A and 17B A hearth extension of this construction may be covered with any noncombustible decorative material and...

Page 18: ...stible and must not be used The floor protection specified includes some form of thermal designation such as R value thermal resistance or k factor thermal conductivity PROCEDURE 1 Convert specificati...

Page 19: ...may be positioned no lower than 60 from base of the fireplace The combustible mantel may have a maximum depth of 12 Combustible trim pieces that project no more than 1 1 2 from the face of the firepl...

Page 20: ...ovided with it Storm Collar Chase Flashing 6 min 2 min 2 min Storm Collar Chase Flashing 2 min 14 1 2 max Top of uppermost chimney section 2 Chase Top Construct a chase of desired materials main taini...

Page 21: ...laced through cracks around windows under doors etc Most newly constructed houses or existing homes fitted with tightly sealed doors and windows are relatively air tight The North Star Fireplace comes...

Page 22: ...y important to reload your fireplace while enough lively hot coals remain in order to provide the amount of heat needed to dry and rekindle the next load of wood It is best to open the air control for...

Page 23: ...installation and installed in a standard wall mount with junction box on the wall 6 Burning Guidelines The Heat Zone accessory kit conveys warm air from the fireplace through air duct s to remote loca...

Page 24: ...ll notice an odor and perhaps see some vapor rise from the fireplace surface this is normal We recommend that you open a window until the odor dissipates and paint is cured NOTE Fireplace should be ru...

Page 25: ...species of wood you burn the single most important factor that affects the way your fireplace operates is the amount of moisture in the wood The majority of the problems fireplace owners experience ar...

Page 26: ...m These three factors work together as a system to create the flue draft Increasing or decreasing any one of them will affect the other two and thus change the amount of draft in the entire system If...

Page 27: ...terials pending final disposal If the ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the closed container until all embers have thoroughly cooled 5 O...

Page 28: ...t affect the finish and little maintenance is required just wipe clean as needed CAUTION Do not use polishes with abrasives as it will scratch the surface IMPORTANT REMOVE ALL LABELS FROM GLASS BEFORE...

Page 29: ...SRV28111 when ordering individual brick Provide brick dimension or copy this page mark the desired brick and take it to your authroized dealer IMPORTANT The bricks are very similar in size Be certain...

Page 30: ...place After Fireplace Installation 1 Remove the firebrick from the bottom of the fireplace 2 Remove the 2 screws from the access panel in the firebox floor 3 Pry up the access panel using the screwdri...

Page 31: ...r the air channel and out of hole at the other end It is necessary to remove the first tube in order to remove the baffle 5 Slide fiber board baffle forward to front of fireplace and straight out thro...

Page 32: ...lace 480 1081 32 4 03 Service Parts Beginning Manufacturing Date 02 17 03 Ending Manufacturing Date __________ EXPLODED VIEW Door Assembly Fascia Assembly Part number list on following page 1 0 27 1 2...

Page 33: ...ng on page 32 832 3400 5 Door Handle Assembly includes 2 door handles HANDLES 480 securing bracket lock nut latch cam key and cam latch 6 Fan Replacement 812 4900 7 Fascia FASCIA NS 8 Glass Assembly f...

Page 34: ...ce Enclosure 16 17 Locations 9 Firestop Spacer 7 Installation 14 Firewood 25 26 Floor Protection 5 Flue 26 Framing 9 10 Fuel 2 25 26 G General Information 21 Glass Cleaning 28 Glass Replacement 28 Gol...

Page 35: ...ents regular maintenance cleaning and temporary repairs do not qualify for a service call fee and will not be covered The replacement of consumer replaceable items and installation of upgraded compone...

Page 36: ...4 03 36 480 1081 PLEASE RETURN THESE INSTRUCTIONS TO THE HOME OWNER WHEN INSTALLATION IS COMPLETE ATTENTION INSTALLER...

Reviews: