background image

Heat & Glo  •  6000CBV-IPI, 8000CBV-IPI  •  2167-900 Rev. C  •  9/09

15

NG                              LP

6000C

6000CL

6000CLX

6000CBV

8000C

8000CL

8000CLX

8000CBV

NOTCH LOCATION

BURNER BOTT

OM

Figure 3.5  Burner Identifi cation

D. Burner Identifi cation/Verifi cation

The burner may be accessed for identifi cation and verifi cation purposes. This task should be performed by a qualifi ed ser-
vice technician.  The base refractory, valve plate, optional refractory and grate do not need to be removed to access the 
burner assembly. The logs and fi ber burner top need to be removed to access the burner.  Disconnect the pilot from the 
burner before removal. See Figure 3.5 for burner identifi cation chart. Notch patterns are located on bottom side of burner.

f i r e - p a r t s . c o m

Summary of Contents for 6000CBV-IPI

Page 1: ...tified professional Leave this manual with party responsible for use and operation DO NOT DISCARD WARNING Important operating and maintenance instructions included Read understand and follow these ins...

Page 2: ...tion Model Number Heat Glo a of Hearth Home Technologies Inc 20802 Kensington Boulevard Lakeville MN 55044 brand Not for use with solid fuel Ne doit pas entre utilise avec un combustible solide This a...

Page 3: ...entification Verification 15 Installer Guide 4 Getting Started A Typical Appliance System 16 B Design and Installation Considerations 17 C Tools and Supplies Needed 17 D Inspect Appliance and Componen...

Page 4: ...the Appliance 36 D Accessories 36 E Burner Top Installation 36 F Ember Placement 36 G Install the Log Assembly 37 H Fixed Glass Assembly 41 I Install Trim and or Surround 41 J Air Shutter Setting 41...

Page 5: ...Heat Glo 6000CBV IPI 8000CBV IPI 2167 900 Rev C 9 09 5 B Limited Lifetime Warranty fire parts com...

Page 6: ...Heat Glo 6000CBV IP 8000CBV IPI 2167 900 Rev C 9 09 6 fire parts com...

Page 7: ...al heating calculations D High Altitude Installations NOTICE If the heating value of the gas has been reduced these rules do not apply Check with your local gas utility or authorities having jurisdict...

Page 8: ...aces are hot during operation AND cool down Hot glass will cause burns DO NOT touch glass until it is cooled NEVER allow children to touch glass Keep children away CAREFULLY SUPERVISE children in same...

Page 9: ...fireplace with the barrier removed Contact your dealer or Hearth Home Technologies if the barrier is not present or help is needed to properly install one For more information refer to the instructio...

Page 10: ...y to light any appliance DO NOT touch any electric switch do not use any phone in your building DO NOT CONNECT 110 VAC TO THE CONTROL VALVE Improper installation adjustment al teration service or main...

Page 11: ...n for 20 to 40 minutes Odor from appliance When first operated this appliance may release an odor for the first several hours This is caused by the curing of the paint and the burning off of any oils...

Page 12: ...intained your fireplace will give you many years of trouble free service We recommend an nual service by a qualified service technician Doors Surrounds Fronts Frequency Annually By Homeowner Tools nee...

Page 13: ...these areas Screw tips that have penetrated the sheet metal are sharp and should be avoided Remove all foreign objects Verify unobstructed air circulation Burner Ignition and Operation Frequency Annua...

Page 14: ...l refractory grate and base refractory do not need to be removed to service the burner assembly NOTICE Remove optional refractory before removing grate If grate is removed first damage to refractory w...

Page 15: ...ification and verification purposes This task should be performed by a qualified ser vice technician The base refractory valve plate optional refractory and grate do not need to be removed to access t...

Page 16: ...F PREFERABLY WITHOUT AFFECTING ROOF RAFTERS SECTION 8 B FRAMING HEADED OFF IN CEILING JOISTS SECTION 8 B GAS LINE SECTION MANTEL AND MANTEL LEG SECTION 5 D SURROUND HEARTH EXTENSION VENT PIPE SECTIONS...

Page 17: ...wdriver Noncorrosive leak check solution 1 2 3 4 in length 6 or 8 Self drilling screws One 1 4 in female connection for optional fan WARNING Risk of Fire Explosion or Electric Shock DO NOT use this ap...

Page 18: ...liances and exhaust equipment Ensure furnace and air conditioning return vents are not located in the immediate vicinity of the fireplace Avoid installing the fireplace near doors walkways or small is...

Page 19: ...ld be locat ed out of traffic and away from furniture and draperies NOTICE Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY Illustrations diagrams are not drawn to scale Ac...

Page 20: ...Install appliance on hard metal or wood surfaces extending full width and depth DO NOT install directly on carpeting vinyl tile or any combustible material other than wood WARNING Risk of Fire Maintai...

Page 21: ...or Wall Projections Acceptable on both sides of opening Combustible Mantels Combustible Mantel Legs or Wall Projections A B INTERIOR WALL TOP VIEW MANTEL LEG OR WALL PROJECTIONS FIREPLACE OPENING If...

Page 22: ...ace with insulation or other materials Failure to keep insulation or other materials away from vent pipe may cause overheating and fire WARNING VERTICAL WALL LISTED B VENT TERMINATION CAP 12 X ROOF PI...

Page 23: ...MINIMUM VENT SUPPORTS ARE PER VENT MANUFACTURER S SPECIFICATIONS MINIMUM CLEARANCES ARE PER VENT MANUFACTURER S SPECIFICATIONS Follow pipe manufacturer s installation guidelines when installing the a...

Page 24: ...raming materials as those used in the wall or ceiling construction Firestop spacers must be used in wall and ceiling penetrations per the B Vent pipe manufacturer s specifications and national regiona...

Page 25: ...Appliance Preparation Figure 9 2 Outside Air Kit Installation Figure 9 1 Damper Assembly and Handle HANDLE HINGE DOOR B Gas and Electrical Connections If applicable ensure that gas and electrical con...

Page 26: ...osition and secure the appliance see Figure 9 4 Nailing tabs are provided to secure the appliance to the framing members Bend out nailing tabs on each side Place the appliance into position Keep naili...

Page 27: ...ure vent sections with vent supports following B vent manufacturer s instructions WARNING Risk of Fire or Explosion Use vent run sup ports per vent manufacturer s installation instructions Connect ven...

Page 28: ...lame Fittings and connections could have loos ened during shipping and handling WARNING Risk of Fire DO NOT change valve settings This valve has been preset at the factory WARNING Risk of Fire or Expl...

Page 29: ...on System Wiring Wire the appliance junction box to 110 VAC for proper operation of the appliance WARNING Risk of Shock or Explosion DO NOT wire IPI controlled appliance junction box to a switched cir...

Page 30: ...MAIN BROWN BLACK RED BATTERY PACK 6V DC AA X 4 FLAME MODULATION THERMOSTAT WIRE ASSEMBLY WALL SWITCH WIRE W H T W HT B L K BLK GRN wire inside box Copper ground attached to GRN screw with GRN wire 14...

Page 31: ...e commands from a wired wall switch and or one of the optional wireless remote options Figure 12 4 Control Module NG LP SETTING STATUS INDICATOR LED SELECTOR SWITCH FLAME HI LO SWITCH RC100 OR WIRED W...

Page 32: ...imum clearances to combustibles as specified in this manual Overlapping materials could ignite and will interfere with proper operation of doors and louvers Figure 13 2 Combustible Mantel Leg or Wall...

Page 33: ...the door mod els and the finishing material thickness allowed NOTICE See service parts list Section 16 B for ordering finishing strips DOOR FIT FINISH MATERIAL THICKNESS SEE FIGURE Folio Inside Any 13...

Page 34: ...INISHING STRIPS USED See Figure 13 7 for attachment instructions NON COMBUSTIBLE FINISHING MATERIAL Figure 13 6 Folio Inside Fit FINISHING STRIP NOT USED NON COMBUSTIBLE FINISHING MATERIAL Figure 13 5...

Page 35: ...8000CBV IPI 2167 900 Rev C 9 09 35 Attachment of Finishing Strips FINISHING STRIPS ATTACHED Figure 13 7 Attaching Finishing Strips NOTICE See service parts list Section 16 B for ordering finishing st...

Page 36: ...it makes full contact with the underlying burner assem bly 3 Reinstall the pilot cover using the two screws removed in step 1 4 Ensure that the ports in the steel burner are visible through the holes...

Page 37: ...TABS LOG PLACEMENT TABS Figure 4 Log 2 SRV2164 702 Mate the slot located on the bottom of Log 2 with the left tab on top of Log 1 After slot and tab have been fitted together mate the groove located o...

Page 38: ...IGHT GRATE TINE RIGHT GRATE TINE 1 1 2 2 3 3 4 4 Figure 8 Figure 9 Figure 10 1 1 1 1 2 2 2 2 3 3 3 3 4 4 5 5 5 5 6 6 Log 5 SRV2164 705 Place Log 5 in the right log indentation on the burner top see Fi...

Page 39: ...t tab on top of Log 1 After slot and tab have been fitted together mate the groove located on the bottom of Log 2 with the horizontal grate bar and slide Log 2 toward the left until it rests against t...

Page 40: ...hould rest against the far left grate tine as well as contact Log 2 Log 5 SRV2168 705 Place Log 5 in the right log indentation on the burner top see Figure 2 Ensure the log fits completely and securel...

Page 41: ...e on the glass frame I Install Trim and or Surround Install optional trim kits and or surrounds using the instructions included with the accessory Use non combustible materials to cover the gap betwee...

Page 42: ...ght side of pilot hood The gap should be approximately 17 in or 1 8 in 3 mm 2 Pilot won t light there is no noise or spark A No power or transformer installed incorrectly Verify that transformer is in...

Page 43: ...de of pilot hood Flame sensing rod should glow shortly after ignition With a multi meter verify that current in series between module and sense lead is at least 0 14 microamps Verify correct pilot ori...

Page 44: ...nces refer to Section 5 Figure 16 1 6000CBV Appliance Dimensions A D B C ELECTRICAL ACCESS F E GAS LINE ACCESS L M J K G H I TOP VIEW RIGHT SIDE LEFT SIDE FRONT VIEW O N Location Inches Millimeters I...

Page 45: ...Dimensions Location Inches Millimeters I 35 1 2 902 J 17 3 4 451 K 6 152 L 2 5 8 143 M 8 7 8 225 N 42 7 8 1089 O 1 25 Location Inches Millimeters A 48 1219 B 43 1092 C 35 1 2 902 D 36 9 16 929 E 2 3 8...

Page 46: ...C 9 09 46 B Service Parts Service Parts Diagram 6000CBV IPI 8000CBV IPI Beginning Manufacturing Date Aug 2009 Ending Manufacturing Date ________ 7 8 9 10 11 12 13 14 Log Set Assembly Part number list...

Page 47: ...6 7 Insulation Board 2166 136 8 Burner Top SRV2166 100 Y 9 Burner NG 2164 007 Y Burner LP 2164 008 Y 10 Log Grate 2166 104 11 Base Refractory SRV6BASE STRAT 12 Refractory Basket 2166 108 13 Glass Door...

Page 48: ...2170 136 8 Burner Top SRV2170 100 Y 9 Burner NG 2168 007 Y Burner LP 2168 008 Y 10 Log Grate 2170 104 11 Base Refractory SRV8BASE STRAT 12 Refractory Basket 2170 108 13 Glass Door Assembly GLA 950TR...

Page 49: ...ry Pack 2166 323 Y 5 Flex Ball Valve Assembly 302 320A Y 6 Valve Bracket 2118 104 7 Valve NG 2166 302 Y Valve LP 2166 303 Y 8 Male Connector 303 315 5 Y 9 Bulkhead W Tube 2166 119 Y 10 Wire Assembly 2...

Page 50: ...______________________________________________ ________________________________________________________________________________ This product may be covered by one or more of the following patents Unit...