D. Electrical Service and Repair
WARNING! Risk of Shock! Label all wires prior to dis-
connection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper
operation after servicing.
Figure 12.1 IPI Wiring Diagram
WARNING! Risk of Shock! Replace damaged wire with
type 105º C rated wire. Wire must have high temperature
insulation.
NOTE: 1
. Ignition module, valve, pilot, and wall switch operate on
3 volts. 120 VAC is required at junction box unless equipped with
battery back-up.
TO JUNCTION
BOX (110V)
MODULE
FLAME
SENSE
IGNITER
RC100 RC200
(OPTIONAL WALL CONTROLS)
GROUND
ORANGE
(PILOT)
GREEN
(MAIN)
BROWN
BLACK
RED
BATTERY PACK
6V DC (AA X 4)
FLAME
MODULATION
THERMOSTAT WIRE
ASSEMBLY / WALL
SWITCH WIRE
WHT
WH
T
BLK
BLK
GRN wire
inside box
Copper
ground attached
to GRN screw with
GRN wire
14/2WG
Cover Plate
outside firebox
Romex
Connector
Figure 12.2 Junction Box Detail
NOTICE: DO NOT wire
110 VAC to wall switch.
E. Junction Box Installation
If the box is being wired from the
INSIDE
of the appli-
ance:
• Remove the screw attaching the junction box/receptacle
to the outer shell, rotate the junction box inward to dis-
engage it from the outer shell (see Figure 12.2).
• Pull the electrical wires from outside the appliance through
the opening into the valve compartment and secure wires
with a Romex connector. See Figure 12.2.
• Make all necessary wire connections to the junction
box/receptacle and reattach the junction box/receptacle
to the outer shell.