Section 5-3
23
MLSM2003-09-03
Procedure N
- Top Burner Valve
Step 1: Disconnect power supply to
range and shut off gas. Pull range
away from wall and remove
backguard held by 3 screws and
washers. See Procedure A Step 1.
Step 2: Prop Top Up. See Proce-
dure P And remove control panel.
See Procedure K (steps 6 & 7).
Step 3: Remove aluminum tubing
from defective valve with wrench.
Step 4: Remove ignition switch.
Wires can remain on switch if new
valve does not have switch factory
installed.
Step 5: Disconnect burner valve
from manifold by removing two 8 mm
nuts.
Step 6: Install new burner valve to
manifold - ensure new valve has
the “o” ring gasket to seal against
the manifold. If not, transfer seal
from old valve.
Step 7: Attach aluminum tube to
new valve.
Step 8: Turn gas on and test for
gas leaks with soapy water solution.
IMPORTANT: ALL GAS WORK TO
BE PERFORMED BY A
QUALIFIED GAS TECHNICIAN.