Hearthstone Quality Home Heating Products, Inc
® Castleton Model 8030 AU
15
9) Tighten the screws. The snap switch should now
touch the stove. If the snap switch does not
touch, simply bend the blower bracket up until
contact is made with the stove. If required,
remove the blower and make the appropriate
corrections.
10) Attach the heat shield.
11) Plug power cord into a grounded, 230 v,
50-cycle 3-prong receptacle. Route the cord
away from hot surfaces. Ensure the cord is not
pinched in any way.
BLOWER
OPERATION:
The snap switch located on the top of the blower
housing activates the blower. It will take several
minutes for the heat of the stove to activate the snap
switch (about 120 degrees F). A rheostat controls
the blower fan speed. The rheostat knob is located
on the right hand side of the blower housing. Turn
the knob clockwise to the on position. The fan is on
the highest setting when first turned on. Continue to
turn the knob clockwise to reduce the fan speed until
it reaches its lowest setting. If the fan does not
operate at the lowest setting, the rheostat requires
adjustment. Contact your dealer for rheostat
adjustment. To turn the blower off, turn the knob fully
counterclockwise until it clicks into the off setting.
Figure 11
Figure 12
Figure 13