The International Residential Code (IRC) does not
allow the outside air duct to terminate higher than
the appliance. Some building officials also do not
Figure 4 – Outside Air Kit Detail
like to see any vertical rise in the duct’s termination.
Hearthstone recommends the termination be at the
same level, or lower than the air intake on the stove.
Locate the termination of the duct on the outside
wall of the home in such a manner to avoid the
possibility of obstruction by snow, leaves or other
material. Screen the termination using ¼” x ¼” mesh
rodent screen and cover it with a rain/wind proof
hood (flex pipe, outside termination, mesh, and hood
supplied by others) Contact your dealer for
availability.
V
ENTING
C
OMPONENTS
&
C
ONFIGURATION REQUIREMENTS
FLUES AND CHIMNEYS
WARNING: THE APPLIANCE AND FLUE-SYSTEM
SHALL BE INSTALLED IN ACCORDANCE WITH
AS/NZS2918 AND THE APPROPRIATE
REQUIREMENTS OF THE RELEVENT BUILDING
CODES.
WARNING: APPLIANCES INSTALLED IN
ACCORDANCE WITH THIS STANDARD SHALL
COMPLY WITH THE REQUIREMENTS OF AS/NZS
4013 WHERE REQUIRED BY THE REGULATORY
AUTHORITY, I.E. THE APPLIANCE SHALL BE
IDENTIFIABLE BY A COMPLIANCE PLATE WITH
THE MARKING ‘TESTED TO AS/NZS 4013.
ANY MODIFICATION OF THE APPLIANCE THAT
HAS NOT BEEN APPROVED IS CONSIDERED TO
BE IN BREACH OF THE APPROVAL GRANTES
FOR COMPLIANCE WITH AS/NZS 4013
CAUTION: MIXING OF APPLIANCE OR FLUE-
SYSTEM COMPONENTS FROM DIFFERENT
SOURCES OR MODIFYING THE DIMENSIONAL
SPECIFICATION OF COMPONENTS MAY
RESULT IN HAZARDOUS CONDITIONS. WHERE
SUCH ACTION IS CONSIDERED, THE
MANUFACUTRER SHOULD BE CONSULTED IN
THE FIRST INSTANCE.
The flue or chimney system must be in good
condition. It must be inspected by a competent
person and passed for use with the appliance before
installation.
Products of combustion entering the room can
cause serious health risks.
You must check the following:
•
The construction of masonry chimneys, flue
block chimneys and connecting flue pipe
system must meet the requirements of the
Building Regulations and the rules in force.
•
A flexible flue liner system must be certified for
use with solid fuel systems and installed to
Building Regulations and the manufacturer’s
instructions. The flue liner must be replaced
when an appliance is replaced unless proven
to be recently installed and in good condition.
•
If it is necessary to fit a register plate it must
conform to the Building Regulations and the
rules in force.
•
Ensure the connecting flue pipe is kept a
suitable distance from any heat sensitive
material and does not form part of the
supporting structure of the building.
•
Make provision to remove the appliance
without the need to dismantle the chimney.
•
Any existing flue must be confirmed as
suitable for the new intended use as defined in
the Building Regulations and the rules in force.
•
The flue or chimney systems must be
inspected and swept to confirm the system is
structurally sound and free from obstructions.
•
If the appliance is believed to have previously
served an open fire the chimney must be
swept a second time within a month 01 regular
use after installation to clear any soot falls that
may have occurred due to difference in
combustion levels.
•
The flue exit from the building must comply
with local building control rules.
•
Do not connect or share the flue or chimney
system with
another heating appliance.