A vertical vent termination system installed on this model

will include one (1) length of 3-inch flexible vent pipe for the

combustion air, one (1) pipe-to-cap adaptor, and one (1) SLK-

991DA or SLK-980D vertical termination cap.

NOTE: 

The damper of the masonry chimney may need to be

removed to allow installation of the flexible-vent  pipe.

This fireplace has been altered to accommodate an insert

and should be inspected by a qualified person prior to

re-use as a conventional fireplace.

NOTE: 

 The above label, located in the instruction package,

must be affixed to the existing fireplace prior to installation

of Model AT-GRAND-D.
For zero clearance, factory built woodburning fireplaces, the

use of kit LINK-ZC-ADP, in place of the standard square

flashing, will allow you to mount the adaptor and cap on

metal pipe.  Additionally, the use of kit FLASH-DAMP will

seal off the damper opening when terminating the inlet air

vent pipe just above the damper. These two kits are

recommended for zero clearance, factory built woodburning

fireplaces.

Connecting the Vent Pipe

Install the 3-inch flexible vent pipes down through the chimney.

Attach and secure the bottom ends of the flex pipes to the

starting collars on the unit with 3 sheetmetal screws on each

collar.  Slide the gas insert into place, and position any excess

flex vent pipe back up into the chimney.
Attach the pipe-to-cap adaptor to the termination cap and

the top of the flexible vent pipe and set the cap in place at

the top of the chimney. See Figures 3, 4 & 5.

CAUTION: TO AVOID DOWNDRAFTS AND/OR COLD AIR

PROBLEMS, IT IS RECOMMENDED TO SEAL OFF THE

AREA BETWEEN THE TERMINATION CAP AND THE TOP

OF THE SOLID-FUEL CHIMNEY OPENING INTO WHICH

THE VENT CAP HAS BEEN INSTALLED.

When using the LINK-DV4-30 vent system, it is required to

seal around the flexible vent pipes in the damper area. See

Figure 3. Use fiberglass insulation or other suitable non-

combustible material.

VENT SYSTEM APPROVALS

AT-GRAND-D     LINK-DV30

LINK-DV4-30

TABLE 1

Un système de ventilation verticale installé sur ce modèle

doit inclure une (1) longueur de conduit de ventilation flexible

d’un diamètre de 7,62 cm (3 in.) pour l’air de combustion,

un (1) raccord du conduit à la mitre et une (1) mitre pour

conduit vertical SLK-991DA ou SLK-980D.

REMARQUE:

 Il peut s’avérer nécessaire de déposer le

registre d’une cheminée en briques avant d’installer le conduit

de ventilation flexible.

Lorsqu’une cheminée a été modifiée pour accepter un

appareil de chauffage au gaz, elle doit être inspectée par

un technicien qualifié avant d’être reconvertie en cheminée

conventionnelle.

REMARQUE: 

L’étiquette ci-dessus, comprise dans

le paquet d’instructions, doit être apposée sur la cheminée

existante avant l’installation du modèle  AT-GRAND-D.
Dans le cas des cheminées de feux de bois fabriquées en

usine et sans espace d’isolation, utiliser le kit LINK-ZC-ADP

à la place du carré de solin ordinaire pour monter le raccord

et la mitre sur le tuyau métallique. Le kit FLASH-DAMP

permet de sceller l’ouverture du registre lorsque le conduit

d’admission d’air se termine juste au-dessus du registre.

Ces deux kits sont recommandés pour les cheminées de

feux de bois fabriquées en usine et sans espace d’isolation.

Raccordement du conduit de ventilation

Installer les conduits de ventilation flexibles de

7,62 cm (3 in.) de diamètre dans la cheminée. Attacher et

fixer les extrémités des conduits flexibles aux colliers de

départ de l’appareil avec 3 vis à tôle sur chaque collier. Glisser

l’appareil de chauffage en place et introduire le conduit flexible

qui dépasse à l’intérieur de la cheminée.
Attacher le raccord prévu à cet effet entre la mitre et le haut

du conduit flexible et poser la mitre au sommet. Voir les

figures 3, 4 et 5.

ATTENTION: POUR ÉVITER LES TIRAGES

INSUFFISANTS OU LES APPELS D’AIR FROID, IL EST

RECOMMANDÉ DE SCELLER COMPLÈTEMENT

L’ESPACE ENTRE LA MITRE ET L’OUVERTURE

SUPÉRIEURE DE LA CHEMINÉE DE COMBUSTIBLES

SOLIDES DANS LAQUELLE LA MITRE EST INSTALLÉE.

Lorsque le système de ventilation LINK-DV4-30 est utilisé,

il est obligatoire de sceller l’espace entre les conduits de

ventilation flexibles et l’ouverture du registre (voir la figure 3).

Utiliser de la laine de verre ou un autre matériau non-

combustible approprié.

HOMOLOGATIONS

AT-GRAND-D       LINK-DV30

LINK-DV4-30

TABLEAU 1

Installing the Insert 

(continued)

Installation 

(suite)

All manuals and user guides at all-guides.com

all-guides.com

Summary of Contents for Heat-N-Glo AT-GRAND-D

Page 1: ...ns le b timent o vous vous trouvez vacuez la pi ce le b timent ou la zone Appelez imm diatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoi...

Page 2: ...reil et remplacer toute partie du syst me de contr le et toute commande qui ont t plong es dans l eau CET APPAREIL NE PEUT PAS TRE UTILIS AVEC DU COMBUSTIBLE SOLIDE FAIRE EFFECTUER l installation et l...

Page 3: ...t toujours D GAG de tout obstacle pour permettre l entretien et assurer un fonctionnement correct Etant donn sa temp rature lev e installer l appareil L CART des zones de passage des meubles et des ri...

Page 4: ...Your Appliance 27 Table of Contents Consignes de s curit 2 Liste des pieces de rechange 5 Section 1 Homologations et codes d installation 7 Homologation et codes 7 Certifications 7 Codes d installatio...

Page 5: ...U S A and Canada 1Approvals and Codes Approval Listing and Codes Homologations et codes d installation Homologations et codes L appareil Certification Les mod les Heat N Glo pr sent s dans ce Guide d...

Page 6: ...oper orifice for your location Approvals and Codes continued Installations haute altitude Les appareils de chauffage au gaz homologu s U L ont t test s et approuv s pour des altitudes comprises entre...

Page 7: ...az Heat N Glo Les chemin es gaz Heat N Glo ventilation directe sont con ues pour aspirer l air de combusion de l ext rieur et refouler les gaz d chappement l ext rieur Sauf avis contraire les informat...

Page 8: ...ne qui ont t install es conform ment tous les codes de construction en vigueur nationaux r gionaux et locaux 2 Les ouvertures minimum requises pour la chemin e sont indiqu es la figure 1 de ce Guide d...

Page 9: ...33 in LARGEUR ARRI RE 610 mm 24 in PROFONDEUR 346 mm 13 5 8 in HAUTEUR 618 mm 24 5 16 in REMARQUE Si le collier d chappement de l appareil de chauffage et le registre de la chemin e ne s alignent pas...

Page 10: ...RQUE La hauteur verticale minimum conduit d chappement est de 4 2 m 14 ft et la hauteur verticale maximum est de 15 m 50 ft Mesurer ces dimensions partir des colliers de d part de l appareil de chauff...

Page 11: ...ible d un diam tre de 7 62 cm 3 in pour l air de combustion un 1 raccord du conduit la mitre et une 1 mitre pour conduit vertical SLK 991DA ou SLK 980D REMARQUE Il peut s av rer n cessaire de d poser...

Page 12: ...the Insert continued Figure 2 Minimum Height from Roof to Lowest Discharge Opening ROOFPITCH H MIN FT Flat to 6 12 1 0 6 12 to 7 12 1 25 Over 7 12 to 8 12 1 5 Over 8 12 to 9 12 2 0 Over 9 12 to 10 12...

Page 13: ...CONDUIT D CHAPPEMENT QU AU COLLIER DE D PART D CHAPPEMENT ET AU COLLIER CENTRAL DE LA MITRE NE RACCORDER LE CONDUIT D ADMISSION D AIR QU AU COLLIER D ADMISSION D AIR ET LE FIXER AU COLLIER D ADMISSIO...

Page 14: ...AIR STARTING COLLAR COLLIER DE D PART D ADMISSION D AIR EXHAUST STARTING COLLAR COLLIER DE D PART D CHAPPEMENT TERMINATION CAP MITRE ADAPTOR ADAPTATEUR INLET AIR COLLAR COLLIER D ADMISSION D AIR EXHA...

Page 15: ...LIVOLTS NEPASRACCORDERUNEVANNE DE COMMANDE SUR 110 120 VCA Step 2 Positioning Leveling and Securing Insert Installing the Insert continued 1 Place the insert into position 2 Level the insert from side...

Page 16: ...ruction locaux L installation doit tre effectu e par un technicien qualifi et ou muni d une licence de mani re respecter les r glements municipaux REMARQUE Purger la conduite d alimentation en gaz de...

Page 17: ...o or less than one half 1 2 psig 3 5 kPa Installing the Insert continued Step 5 Gas Pressure Requirements tape 5 Sp cifications relatives la pression du gaz Une d rivation de visite NPT de 3 mm est pr...

Page 18: ...ations Cet appareil NE DOIT PAS tre raccord une source de courant 110 120 V CA pour fonctionner ADVERTISSEMENT NE PAS RACCORDER LA VANNEDECOMMANDESUR110 120VCAPOUR VITER UN MAUVAIS FONCTIONNEMENT OU L...

Page 19: ...te Figure 9 Sch ma de c blage du ventilateur NOTE IFANY OF THE ORIGINALWIRE AS SUP PLIED WITH THE APPLIANCE MUST BE RE PLACED IT MUST BE REPLACED WITH TYPE 1050 C RATED WIRE REMARQUE S IL EST N CESSAI...

Page 20: ...door Installing the Insert continued Installation suite Positionnement des b ches Si les b ches sont mont es d usine il est inutile de les repositionner Si les b ches sont livr es dans un emballage s...

Page 21: ...gure 11 Placement of the Ember Material 1 Souleverl encadrementdela porte et le retirer 2 Desserrer les attaches et d poser la porte Figure 10 Porte en verre Figure 11 Pose des braises 1 Placer les br...

Page 22: ...ert See Figure 12 2 Disconnect the ON OFF switch from the low voltage wire leads and insert the ON OFF switch through the hole at the upper right corner of the surround it will be retained in the hole...

Page 23: ...tension l interrupteur MARCHE ARR T 4 D poser et mettre de c t les quatre vis de fixation de l encadrement aux quatre coins de l avant de l appareil voir la figure 12 5 Glisser l encadrement contre l...

Page 24: ...llumer l appareil de chauffage au gaz ne pas oublier de Relire et assimiler les consignes de s curit Relire la section Consignes de s curit au d but de ce Guide d installation V rifier qu il n y a pas...

Page 25: ...uence d entretien et de r vision de la chemin e d pende du volume d utilisation et du type d installation nous recommandons un examen de l appareil par un technicien qualifi au d but de chaque saison...

Page 26: ...et r vision suite Figure 14 Burner Flame Patterns Make sure the flames are steady not lifting or floating S assurer que les flammes sont stables qu elles ne montent pas et ne flottent pas Figure 14 Co...

Reviews: