background image

March 19, 2003                                                                       23                       

 

  

                 250-6422

Castile Pellet Stove

R

LIMITED LIFETIME WARRANTY

The Hearth & Home Technologies limited Lifetime Warranty guarantees that the following components will work as designed 

for the lifetime of the stove or Hearth & Home Technologies will repair or replace them.  These items include but are not 

limited  to  steel  and  cast  iron  components,  all  gas  burners,  gas  logs,  combustion  chambers,  heat  exchanger  systems, 

stainless  steel  firebox  components,  plating,  doors,  glass  damaged  by  thermal  breakage,  steel  baffle  supports,  steel  and 

ceramic baffles and manifold tubes. Labor is for the first five years.

THREE YEAR WARRANTY

Our EZ Clean firepots are covered under Hearth & Home Technologies three-year warranty program.  Labor is for 3 years.

TWO YEAR WARRANTY

All  electrical  components  such  as  but  not  limited  to  blowers,  wiring,  vacuum  switches,  speed  controls,  control  boxes, 

thermodisc switches, pilot assembly, gas valves, thermostats and remotes are covered under Hearth & Home Technologies 

two-year warranty program.  

ONE YEAR WARRANTY

Porcelain  finishes  are  warranted  against  manufacturer  defects  for  one  year.    Labor  to  repair  or  replace  these  parts  is 

covered for one year, reimbursed per our warranty service fee schedule.

CONDITIONS

This warranty is non-transferable and is made to the original retail purchaser only provided that the purchase was made 

through an authorized dealer of Hearth & Home Technologies It must be installed and operated at all times in accordance 

with  the  Installation  and  Operating  Instructions  furnished  with  this  product,  as  well  as  any  applicable  local  and  national 

codes.  Any alteration, willful abuse, accident, or misuse of the product shall nullify this warranty.

Labor to repair or replace items covered under the limited Lifetime Warranty will be covered for the first five years per our 

warranty service fee reimbursement schedule.   Parts covered under the limited Lifetime Warranty will be covered for the 

lifetime of the appliance up to a maximum of ten (10) years after Hearth & Home Technologies discontinues the model and 

two (2) years for optional accessories.  Adjustments, regular maintenance, cleaning and temporary repairs do not qualify for 

a service call fee and will not be covered.  The replacement of consumer replaceable items and installation of upgraded 

component parts do not quality for a service call fee, and will not be covered.

This limited Lifetime Warranty does not extend to or include surface finish on the appliance, door gasketing, glass gasketing, 

firebrick, kaowool or other ceramic insulating materials.  It does not cover installation or operational-related problems such 

as overfiring, use of corrosive driftwood, downdrafts or spillage caused by environmental conditions, nearby trees, buildings, 

hilltops,  mountains,  inadequate  venting  or  ventilation,  excessive  offsets,  or  negative  air  pressures  caused  by  mechanical 

systems such as furnaces, fans, clothes dryers, etc.

Any  installation,  construction,  transportation,  or  other  related  costs  or  expenses  arising  from  defective  part(s),  repair, 

replacement, etc., will not be covered by this warranty, nor will Hearth & Home Technologies assume responsibility for them.  

Further, Hearth & Home Technologies will not be responsible for any incidental, indirect, or consequential damages, except 

as  results  in  damage  to  the  interior  or  exterior  of  the  building  in  which  this  appliance  is  installed.    This  limited  Lifetime 

Warranty does not apply to the venting components, hearth components or other accessories used in conjunction with the 

installation of this product not manufactured by Hearth & Home Technologies

This warranty is void if the stove has been overfired or operated in atmospheres contaminated by chlorine, fluorine, or other 

damaging chemicals, the stove is subjected to prolonged periods of dampness or condensation, or there is any damage to 

the stove or other components due to water or weather damage which is the result of, but not limited to, improper chimney 

or venting installation.  Hearth & Home Technologies may, at its discretion, fully discharge all obligations with respect to this 

warranty by either repairing or replacing the unit, or refunding the wholesale price of the defective part(s).

This limited Lifetime Warranty is effective on all appliances sold after May 1, 2002 and supersedes any and all warranties 

currently in existence.

Policy 250-8620  Rev C

Lifetime Warranty

Summary of Contents for QUADRA-FIRE

Page 1: ...OVERFIRING VOIDS WARRANTY 5 DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM DO NOT INSTALL A FLUE DAMPER IN THE EXHAUSE VE...

Page 2: ...inserts and fireplaces And yet we are old fashioned when it comes to craftsmanship Each unit is meticulously fabricated and gold surfaces are hand finished for lasting beauty and enjoyment Our pledge...

Page 3: ...Chimney and Exhaust Connections 5 Venting Termination Requirements 5 Vent Graph and Table 5 Venting Systems A Alcove 6 B Through the wall 6 C Vertical 7 D Through the wall and vertical 7 E Masonry 7 F...

Page 4: ...and to the sides front and back of unit as shown in Floor Protection Diagram Measure front distance I from the surface of the glass door Exceptions US INSTALLATIONS Recommend a non combustible floor...

Page 5: ...shielding or guards may be required 3 Termination must exhaust above air inlet elevation It is recommended that at least 60 1524mm of vertical pipe be installed when appliance is vented directly thro...

Page 6: ...5 Degree VENTING SYSTEMS Straight Out A ALCOVE The Quadra Fire Castile is approved for minimum alcove height of 43 1092mm a maximum alcove depth of 36 914mm and a minimum alcove side wall of 6 152mm A...

Page 7: ...Cap Flashing 2 51mm minimum 6 152mm minimum VENTING SYSTEMS CONT C VERTICAL D THROUGH THE WALL VERTICAL E MASONRY F ALTERNATE MASONRY Non combustible Hearth Pad Airtight Cleanout Door Cleanout cover S...

Page 8: ...nt Adapter remove clean out cover NOTES 1 The Feed Adjustment Rod is factory set and should be adequate for most fuels However if the flame height is too high or too low follow the instructions below...

Page 9: ...ZE AND MATERIAL Wood Pellets Fuel pellets are made from sawdust or wood by products If the source material is hardwood they will have a higher mineral content creating a heavier ash Minerals and other...

Page 10: ...es in that when the thermostat calls for heat your stove will automatically light and deliver heat in the most efficient and economical way When the room is up to temperature and the thermostat is sat...

Page 11: ...ppermost portion of the Heat Exchanger Tubes This area is only accessible when the baffle is removed from the stove Reinstall panels and baffle and latch when finished cleaning NOTE Unplug the stove b...

Page 12: ...this removed the blower and housing may now be removed There are four screws that attach the blower housing Two on each side Loosen all four screws but do not remove them Now lift the blower housing...

Page 13: ...s to indicate that the stove has reached operating temperature If the red light does not come on in the first nine minutes of start up the stove will shut 1 POWER SUPPLY a Check the wall receptacle fo...

Page 14: ...surges can also trip this Snap Disc To reset unplug the stove from outlet and push in the Red Reset Button in the center of the Snap Disc then plug the stove back in and try to relight it 13 BLOWER 1...

Page 15: ...sure that the floor of the firepot is closing completely 18 DOOR GASKET ROPE a To inspect the door gasket rope open the door and see that the door rope extends approximately 1 8 3mm to 3 16 9 5mm fro...

Page 16: ...ews 5 Measure distance from floor to air vent opening in stove and mark location on wall Use saw to cut opening in wall Cut a 2 1 2 to 3 64mm to 76mm opening on inside wall and a 3 to 3 1 2 76mm to 89...

Page 17: ...he top baffle and the inside of the firebox cen tered from side to side The latch pivots up and down 2 Push the latch up with your finger while sliding the top baffle forward and down See Figure 17A 3...

Page 18: ...he Thermocouple and the Thermocouple Cover should extend approximately 1 25mm into the firepot for accurate temperature reading 3 Push the Reset Button When the Thermocouple reaches 200 F 93 C the TRO...

Page 19: ...jumper wire in order to create a manual bypass to determine if the stove or the thermostat is faulty NOTE Unplug the stove while hooking up the jumper wire Plug the stove back in and the unit should...

Page 20: ...AUGER MOTOR BLUE COMB BLOWER WHITE NEUTRAL IN NEUTRAL AUGER NEUTRAL CONV NEUTRAL COMB NEUTRAL IGN HT M RED WHT SNAP DISC 1 M IGNITER HT M BURN RATE LIGHT P B FUSE AUG CAP ORANGE BLUE GRAY BLACK YELLOW...

Page 21: ...ot scraper paint fasteners power cord wire harness thermostat igniter owner s manual video and warranty card 812 4940 Control Box 812 4890 Door Assembly with Glass 812 4421 Feed Motor 812 4430 Firepot...

Page 22: ...llet Stove R 3 4 5 6 2 1 7 8 9 10 11 12 1 Control Box 2 Convection Blower 3 Exhaust Blower 4 Feed Motor 5 Firepot 6 Glass Door Assembly EXPLODED VIEW 7 Igniter 8 Junction Box 9 Snap Disc 1 10 Snap Dis...

Page 23: ...essories Adjustments regular maintenance cleaning and temporary repairs do not qualify for a service call fee and will not be covered The replacement of consumer replaceable items and installation of...

Page 24: ...March 19 2003 250 6422 24 PLEASE RETURN THESE INSTRUCTIONS TO THE HOME OWNER WHEN INSTALLATION IS COMPLETE ATTENTION INSTALLER R...

Reviews: