9
Hearth & Home Technologies • Vertical Power Vent (PVV-SLP) Instructions • 4071-900 Rev. C • 11/19
C. Vent Cap Preparation
1. Remove 4 screws from top cap and lift off the housing
assembly. See Figure 3.6.
Figure 3.6 Remove Top Cap Screws
Figure 3.8 Remove Screws from PVV-SLEEVE Starting Collar
Figure 3.7 Remove Shipping Support Foam
2. Remove the foam shipping support from the PVV-SLP.
See Figure 3.7.
Figure 3.9 Sufficient Wire Extending Through Bracket
3. Place the PVV-SLP upside down on a flat surface and
remove the 4 screws from the PVV-SLEEVE starting
collar. Remove the starting collar and set aside. See
Figure 3.8.
4. Ensure there are 8-9 inches of wire extending out of
the 90° PVI wire harness fitting. See Figure 3.9.