21
Hearth & Home Technologies • Vertical Power Vent (PVV-SLP) Instructions • 4071-900 Rev. C • 11/19
STEP 1
PLUG-IN
REMOTE
JUMPER WIRE
ORG
G
R
N
B
R
N
B
R
N
RED
BLK
INTERMITTENT
PILOT IGNITOR
ORG
WHT
IGNITION MODULE 3 VAC
TRANSFORMER
VALVE
3 VAC
THERMOSTAT
WIRE
ASSEMBLY
STEP 3
STEP 2
STEP 5
STEP 4
STEP 6
Figure 4.8 IntelliFire™ (Green) IPI Module Wiring as Shipped from Factory
IntelliFire™ IPI Module (Green)
Refer to Figure 4.8 for steps 1 through 6.
1. Remove and discard wire harness connecting the valve
to the control module.
2. Unhook the 3V transformer and discard. This will no
longer be used.
3. Remove and discard battery pack (if present).
4. Detach the white and orange wires from the control
module.
5. Remove the green control module. This will no longer
be used.