INSTALLATION
The type of control used to power the appliance is the
determining factor in making the appliance compatible
with the PVV-SLP.
• A 7/8 in. diameter hole must be bored in the side of
the fireplace outer wrap in which the 5 wires from the
power vent will be routed. The hole should be located
2 inches to the side of the junction box and 4-inches
up from the base of the fireplace.
IntelliFire™ Plus IPI Module (Black)
1. Attach the new 8K1-PVI module to the 6V transformer.
2. Connect the pilot wires (white to S and orange to I) to
the 8K1-PVI module.
3. Connect the new Aux RC300 to the 8K1-PVI module.
4. Plug the Aux RC300 into the Junction Box.
5. Attach the 8K1-PVI wire harness to the 8K1-PVI
module. Connect green and orange valve wires and
reconnect ground wire to chassis.
6. Connect the accessory cable coming from the
PVV-SLP to the AUX RC300 (AUX 2 port) and the
corresponding colored wire on the wire harness.
7. Connect the stepper motor wires to the 8K1-PVI
module.
STEP 4
ORANGE
(PILOT)
GREEN
(MAIN)
GROUND
WHT
AUX 1 AUX 2
TO JUNCTION BOX 110VAC
ORG
TO JUNCTION BOX
110VAC
BROWN
RED
STEP 1
STEP 2
STEP 3
STEP 5
STEP 6
STEP 7
PILOT
8K1-PVI
AUX RC300
MODULE
8K1-PVI
WIRE HARNESS
VALVE
ACCESSORY CABLE
PVI WIRE HARNESS
PVV-SLP
Figure 4.7 PVV-SLP Wiring for IntelliFire™ Plus RC100, RC200, RC300 Controls