Hearth & Home Technologies • CK-30 Cabinet Kit Installation Manual • 4126-900 Rev A • 07/22
20
High Wind Termination Cap
(Part SLP-TVHW)
Top Adaptor
(Included in Link-Stove Kit)
(3) Sheet Metal
Screws
Flashing
(Included in Link-Stove Kit)
Figure 4.17
9. Attach the flex to the retro connector. Use three sheet
metal screws to attach the flex liner to the connector
.
Mount the retro connector to the masonry wall using
masonry bolts.
See Figure 4.18. Redrill larger holes
on connector as needed. Be careful to ensure that the
connector is centered in the opening and the mounting
holes line up with the masonry wall.
6 in. (152mm) diameter
opening in masonry wall
(3) Masonry Bolts
(Not included)
Retro Connector
(Included in Masonry Chimney
Conversion Kit)
(4) Masonry Bolts
(Not included)
Retro Connector
(Included in Masonry
Chimney Conversion Kit)
Wall Thimble Cover
(Included in Masonry Chimney Conversion Kit)
Figure 4.16
8
.
Secure the top adapter to the flashing. Use three sheet
metal screws through the side of the top adapter into the
flange on the flashing See Figure 4.17. Twist lock the
high wind termination cap on to the top adapter.
Flex Liner
(3 in. Part 3DFA-35)
(4 in. Part 4DFA-35)
Flex Coupler
(3 in. Part 3DFA-FC)
(4 in. Part 4DFA-FC)
Sheet Metal Screws
Figure 4.19
Figure 4.18
10.
Slide wall thimble cover over retro connector and secure
with masonry bolts.
See Figure 4.19. If you have a
framed wall in front of the masonry, use wood screws
to mount wall thimble cover to framed wall, over retro
connector and 10 in. (254mm) square framed opening
See Figure 4.14. If needed, add a section of direct vent
pipe to the retro connector in order to extend through
the opening in the wall thimble cover.
11.
The connection between the appliance and the retro
connector may be completed with sections of direct
vent pipe.