ECO CHOICE PELLET STOVE SERVICE MANUAL

CLEANING & MAINTENANCE TIPS

FIREPOT:

  THE FIREPOT NEEDS TO BE CLEANED AS NEEDED.  THE  BUILD-UP OF CLINKER 

MATERIAL WILL DEPEND ON THE QUALITY OF THE FUEL BEING USED.  IN SOME 

CASES, IT MAY BE NECESSARY TO CLEAN THE FIREPOT ON A DAILY BASIS.

  FIREPOT CLEANING INVOLVES SIMPLY PULLING THE CLEANOUT ROD ON THE RIGHT 

SIDE OF THE STOVE.  IF THE ROD IS HARD TO PULL, IT MAY BE NECESSARY TO USE 

THE SCRAPER OR SCREW DRIVER TO CHIP AWAY THE CARBON MATERIAL THAT HAS 

BUILT UP ON THE BOTTOM PLATE OF THE FIREPOT.  ONCE THE DEBRIS IS CHIPPED 

AWAY, THE ROD WILL BE EASY TO PULL.

VENT / CHIMNEY SYSTEM:

  THIS NEEDS TO BE CLEANED AND INSPECTED AT LEAST ONCE A YEAR.  IT MAY BE 

NECESSARY TO PERFORM MORE FREQUENT CLEANING IF THERE IS A LOT OF HORI-

ZONTAL PIPE SECTIONS.  ASH WILL BUILD UP MORE QUICKLY IN THE HORIZONTAL 

SECTIONS.

FIREBOX ASH:

  THE FIREBOX ASH SHOULD BE REMOVED AT THE SAME TIME THAT THE FIREPOT 

IS CLEANED.  FREQUENT CLEANING OF THE ASH IN THE FIREBOX WILL HELP SLOW 

DOWN THE BUILD-UP OF ASH IN THE EXHAUST BLOWER AND VENT SYSTEM.  REMEM-

BER TO DEPOSIT ASHES IN A NONCOMBUSTIBLE CONTAINER.

BLOWERS:

  THE BLOWERS MAY ONLY NEED TO BE CLEANED ONCE A YEAR.  IF THE USE OF 

THE STOVE IS HEAVY, THEN IT MAY NEED TO BE DONE MORE FREQUENTLY.  IF THE 

BLOWER IS GETTING NOISY, THEN THE FAN BLADES WILL NEED TO BE CLEANED.

PAGE 25

Summary of Contents for PS35

Page 1: ...nt part not approved by Hearth Home Technologies Operating appliance without fully assembling all components Operating appliance without legs attached if supplied with unit Do NOT Overfire Or any such...

Page 2: ...GNITER TROUBLE SHOOTING EXHAUST BLOWER TROUBLE SHOOTING CONVECTION BLOWER TROUBLE SHOOTING POWER SUPPLY TROUBLE SHOOTING THERMOSTAT TROUBLESHOOTING THERMOCOUPLE TESTING FIREPOT EXHAUST SYSTEM TROUBLE...

Page 3: ...TIONS 5 CHECK VACUUM SWITCH AND VACUUM HOSE 6 CHECK FEED MOTOR 7 CHECK EXHAUST BLOWER 8 CHECK HOPPER SWITCH C CALL LIGHT ON NO FIRE PARTIALLY BURNED FUEL IN POT 1 CHECK FIREPOT AND CLEAN 2 CHECK THERM...

Page 4: ...UNIT 1 CHECK THERMOSTAT WIRES FOR CONTINUITY 2 CHECK THE HOPPER SWITCH 3 CHECK THE RESET BUTTON 4 CHECK FOR POWER TO THE STOVE 5 CHECK CONTROL BOX F STOVE RUNS FOR 18 MINUTES THEN STOPS FEEDING FUEL 1...

Page 5: ...BUILD UP DIRTY GLASS 1 CHECK FIREPOT MAY NEED TO BE CLEANED 2 CLEAN EXHAUST AND HEAT EXCHANGER SYSTEM 3 ADJUST FEED ADJUSTMENT PLATE IN THE HOPPER 4 CHECK CONTROL BOX FEED TIMES M STOVE IGNITES GOES O...

Page 6: ...THE STOVE AND MAKE SURE THAT EACH OPERATION IS TAKING PLACE THERMOSTAT TURNS ON RED CALL LIGHT ILLUMINATES ON THE STOVE START 1 EXHAUST BLOWER TURNS ON 2 IGNITER TURNS ON 3 VACUUM SWITCH CLOSES 4 ITE...

Page 7: ...N THE CONTROL BOX 12 1mVDC 9 ITEMS TO CHECK POSSIBLE PROBLEMS OR FAILED COMPONENT BOX 5 2 SNAP DISC WIRE CONNECTIONS FEED MOTOR CONTROL BOX HOPPER SWITCH BOX 6 FIREPOT FEED ADJUSTMENT PLATE VENT PIPE...

Page 8: ...IRE CLOSES 1 SNAP DISC 11 ITEMS TO CHECK POSSIBLE PROBLEMS OR FAILED COMPONENT BOX 10 CONTROL BOX BOX 11 1 SNAP DISC WIRE CONNECTIONS WIRE HARNESS CONVECTION BLOWER BOX 12 CONVECTION BLOWER WIRE CONNE...

Page 9: ...FF 16 EXHAUST BLOWER STARTS 18 MINUTE COUNTDOWN 17 1 SNAP DISC COOLS OFF 18 CONVECTION BLOWER SHUTS OFF 19 OPERATION FLOWCHART ITEMS TO CHECK POSSIBLE PROBLEMS OR FAILED COMPONENT BOX 15 THERMOSTAT TH...

Page 10: ...ANGE WIRE ON THE HOPPER SWITCH A IF NO POWER FROM ORANGE WIRE CHECK WIRE HARNESS OR HOPPER SWITCH B IF POWER IS PRESENT CHECK 2 SNAP DISC NOTE REMEMBER THAT THE FEED CIRCUIT INITIAL FEED TIME IS 60 SE...

Page 11: ...IS PRESENT REPLACE THE IGNITER A IF NO POWER CHECK THE WIRE HARNESS OR REPLACE THE CONTROL BOX 2 CHECK FOR POWER AT THE IGNITER PAGE 11 Shock hazard Do NOT remove grounding prong from plug Plug direct...

Page 12: ...R HOOKED UP TO THE HAR NESS ONE LEAD FROM THE VOLTMETER MUST BE CONNECTED TO THE BLUE WIRE ON THE MOTOR AND THE OTHER LEAD CONNECTED TO THE WHITE WIRE FROM THE POWER SUPPLY CLOSED CIRCUIT VOLTAGE WILL...

Page 13: ...R REPLACE CONTROL BOX OPEN CIRCUIT VOLTAGE TO ONE SIDE OF SNAP DISC WILL BE 115 V FOR THE HIGH SETTING ONLY NOTE THE VOLT METER MUST HAVE ONE LEAD CONNECTED TO THE WHITE NEUTRAL WIRE FROM THE POWER SU...

Page 14: ...PLACE THE FUSE OR THE FUSE HOLDER B IF POWER IS PRESENT CONTINUE TO STEP 3 3 CHECK FOR POWER AT THE GREY WIRES ON SNAP DISC 3 SEE FIG 3 A IF NO POWER RESET THE SNAP DISC OR REPLACE IT B IF POWER IS PR...

Page 15: ...WER CORD SEE FIGURE 5 2 SET THE VOLT METER TO OHMS AND PUT THE PROBES ON PIN 5 PIN 12 SEE FIGURE 4 IF THE CIRCUIT IS COMPLETE THE READING SHOULD BE 0 JUMPER WIRE FIGURE 5 FIGURE 4 FIGURE 2 BLACK WIRE...

Page 16: ...ALL A JUMPER WIRE ON THE THERMOSTAT CHECK FOR CONTINUITY AT PIN 7 PIN 9 IF THE CIRCUIT HAS CONTINUITY REPLACE THE THERMOSTAT IF NO CONTINUITY CONTINUE TO THE NEXT STEP 5 REMOVE THE THERMOSTAT WIRES FR...

Page 17: ...LL FLASH IF THE CIRCUIT IS OPEN OR IF THE THERMOCOUPLE IS FRACTURED NOTE BE SURE TO SET THE METER TO MILLIVOLTS DC AND A JUMPER WIRE MAY NEEDED TO CHECK MILIVOLTS WHILE THE THERMOCOUPLE IS HOOKED UP 1...

Page 18: ...INTO A ROUND OPENING LOCATED AT THE LOWER REAR OF THE UNIT SEE FIGURE 2 THIS AIR TRAVELS INTO THE ASHPAN AREA LOCATED BELOW THE BOTTOM OF THE FIREPOT SEE FIGURE 3 COMBUSTION AIR WILL FLOW THROUGH THE...

Page 19: ...AL FIREPOT AND EXHAUST SYSTEM TROUBLE SHOOTING FIG 1 FIG 2 EXAMPLE OF A VERY LARGE CLINKER COMBUSTION AIR INTAKE FIREPOT AIR INTAKE IN THE COMBUSTION CHAMBER LOCATED UNDER ASH PAN FIREBOX AREA w BAFFL...

Page 20: ...ECO CHOICE PELLET STOVE SERVICE MANUAL FIREPOT AND EXHAUST SYSTEM TROUBLE SHOOTING EXHAUST BLOWER WITH THE BAFFLES REMOVED VENT PIPE ADAPTER FIG 5 FIG 6 EXHAUST BLOWER PAGE 20...

Page 21: ...ECO CHOICE PELLET STOVE SERVICE MANUAL COMPLETE WIRE DIAGRAM PAGE 21...

Page 22: ...150 380 4 AMPS EXHAUST BLOWER CONVECTION BLOWER IGNITER FEED MOTOR 25 52 3 3 03 48 1 3 3 3 03 115 115 94 80 85 75 109 103 104 91 45 150 70 220 35 000 50 000 FEED MOTOR ON TIMES HIGH MEDIUM LOW 9 to 1...

Page 23: ...LATE SET AT __________________________________ IS THE FEED SYSTEM OPERATING _____________________________________________ IS THERE POWER TO THE STOVE ______________________________________________ IS...