ECO CHOICE PELLET STOVE SERVICE MANUAL
CONVECTION BLOWER TROUBLE-SHOOTING
1) CHECK FOR POWER AT THE PURPLE WIRE FROM THE #11 PIN AT THE SNAP DISC
A. IF POWER IS PRESENT ON BOTH SIDES OF THE DISC: CHECK THE WIRE HARNESS OR REPLACE
THE CONVECTION BLOWER (Stove must be hot to create a closed circuit on the snap disc.)
B. IF POWER IS PRESENT ON JUST ONE SIDE: REPLACE THE SNAP DISC
C. IF NO POWER IS PRESENT: CHECK THE FUSES & WIRE HARNESS OR REPLACE CONTROL BOX
OPEN CIRCUIT VOLTAGE TO ONE SIDE OF SNAP DISC WILL BE 115 V FOR THE HIGH SETTING ONLY
NOTE: THE VOLT METER MUST HAVE ONE LEAD CONNECTED TO THE WHITE NEUTRAL WIRE FROM
THE POWER SUPPLY TO BE ABLE TO READ THE CORRECT VOLTAGE AT THE SNAP DISC. A JUMPER
WIRE CAN BE USED ON #1 SNAP DISC TO CREATE A CLOSED CIRCUIT.
7 AMP FUSE
JUNCTION BOX
#1 SNAP DISC
CONVECTION BLOWER CIRCUIT
WHITE
CONVECTION
BLOWER
PURPLE
PURPLE
CALL LIGHT
PAGE 13
CLOSED CIRCUIT VOLTAGE WILL BE:
(PS35)
115 V (HIGH) 94 V (MEDIUM) 80 V (LOW)
(PS50)
115 V (HIGH) 85 V (MEDIUM) 75 V (LOW)