Hearth & Home Technologies • CFL-18/24/30-C, CFL-24-IPI, ST-CFL-24-B • 526-910 Rev. L • 11/14
4. REMOTE CONTROL
• If a remote control is used, the receiver cannot be placed
under the burner. If possible, place the receiver outside
the combustion chamber.
• If the receiver must be placed in the combustion chamber,
the protective heat shield MUST be used. See Figure 4.
• Position receiver on left side of gas log set (opposite the
pilot). Place protective heat shield over receiver. See
Figure 5.
Figure 4. Protective Heat Shield
Figure 5. Receiver Location-Left Side of Log Set
RECEIVER
RECEIVER
3. AIR SHUTTER SETTINGS.
This appliance has an adjustable air shutter (which con-
trols the primary air) factory set for the minimum vertical
vent run. If your installation has more than the minimum
required vertical vent length, adjustment of the air shutter
may be necessary to obtain optimal
fl
ame appearance.
This should be adjusted by a quali
fi
ed installer at the
time of installation.
Air Shutter Settings
NG
LP
Burner
3/8 in.
Full Open