This log set is to be installed only in a solid-fuel burning
fi
replace with a working
fl
ue and one constructed of non-
combustible material. The minimum permanent vent open-
ing provided by the
fi
replace chimney damper to vent the
fl
ue products must not be less than 51 square inches (328
cm
2
). The chimney damper MUST be
fi
xed in a manner to
maintain the minimum permanent vent opening. This may
be accomplished by fastening the damper stop clamp pro-
vided to the edge of the damper to prevent its closing.
The installation, including provisions for combustion and
ventilation air, must conform with the National Fuel Gas
Code ANSI Z223.1 (in the United States), the CAN/CGA
B-149 Installation Code (in Canada) and applicable local
building codes.
These models can be installed in a bedroom (in the United
States) which has a total volume of uncon
fi
ned space ap-
propriate to the particular installation. Refer to the National
Fuel Gas Code ANSI Z223.1/NFPA 54-(current edition).
The Uniform Mechanical Code (current edition), and Local
Building Of
fi
cials for the options allowed in obtaining an
effective bedroom volume of uncon
fi
ned space.
Always keep the appliance area clear and free from com-
bustible materials, gasoline, and other
fl
ammable vapors
and liquids.
WARNING! Risk of Fire, Explosion or Electric Shock!
DO NOT
use this appliance if any part has been under
water. Call a quali
fi
ed service technician to inspect the
appliance and to replace any part of the control system
and/or gas control which has been under water.
A. Appliance Certi
fi
cation
WARNING
Fire Risk
Asphyxiation Risk
These gas log sets have been tested and listed in the U.S.
in accordance with
ANSI
Z21.60b-2004
. They have been
listed by Underwriters Laboratories Inc. for installation and
operation in the United States and Canada as described in
these Installation and Operation Instructions. All compo-
nents are UL, AGA, CGA or CSA safety certi
fi
ed.
Check with your local building code agency prior to install-
ing this appliance to ensure compliance with local codes,
including the need for permits and follow-up inspections. In
the absence of local codes, comply with the National Fuel
Gas Code, ANSI Z223.1-Latest Edition in the U.S. If any
assistance is required during installation, please contact
your local dealer.
CAUTION
Check the construction of the
fi
replace before installing the
gas log set. The area of the
fl
ue should not be less than 1/11
the area of the
fi
replace opening. Non-airtight glass doors
should be installed on the
fi
replace if the area of the
fl
ue
is less than 1/11 the area of the
fi
replace opening. Airtight
doors must never be used with this gas log set.
Fire Risk
• THIS UNIT IS NOT FOR USE WITH SOLID
FUEL. Solid fuels shall not be burned in a
fireplace where a decorative appliance is
installed. Failure to follow these instructions
will result in a
fi
re.
WARNING
1
1
Introduction
Gas Log Sets are Decorative Gas Appliances for Installa-
tion in a Solid-fuel Burning Fireplace. Minimum
fi
replace
sizes for these models is shown in Figure 1.
MODELS:
CFL-18NG/LP-C, CFL-24NG/LP-C, CFL-
30NG/LP-C, CFL-24NG/LP-IPI and ST-CFL-24NG/LP-B
LABORATORY:
Underwriters Laboratories, Inc. (UL)
TYPE:
Decorative Gas Appliances for Installation in
Solid-Fuel Burning Fireplaces
STANDARD:
ANSI Z21.60b-2004 CSA 2.26b-2004
• This log set must NOT be installed in an unvented
appliance.
• Open the chimney damper to its fully open position when
burning this gas log set.
• Logs must never be burned without the
fl
ue damper in the
full open position. Failure to do so is dangerous to your
health and voids all warranties.
• All gas appliances produce some carbon monoxide when
operated. Carbon monoxide is a colorless, odorless,
poisonous gas. Adequate provisions must be made to
provide combustion air for this gas log set. If outside air is
not accessed by the
fi
replace, it may be necessary that an
additional combustion air source be provided.