Hearth & Home Technologies Inc. • Cinch Pipe & Term Caps • 4033-900 Rev K • 05/05

6

C. Assemble Vent Sections

Figure 2.5 

Lances

A

B

Figure 2.6 

Inner/Outer

A

B

Figure 2.7 

Snapped

CORRECT

INCORRECT

Make sure the seams are not aligned to prevent unintentional 
disconnection.

Figure 2.8 

Seams

Fire Risk
Exhaust Fumes Risk

•  Overlap pipe slip sections at least 

1-1/2 inches.

•  Use pilot holes for screws.
•  Screws must not exceed one inch long.
•  Pipe may separate if not properly 

joined.

WARNING

Attaching Vent to the Firebox Assembly

To attach the fi rst pipe section to the collars, slide the male 
end of the inner vent of the pipe section over the inner collar 
on the fi rebox assembly. At the same time, slide the outer 
fl ue over the outer collar on the appliance. Push the pipe 
section into the appliance collar until all the lances (see Fig-
ure 2.5) have snapped in place. Tug slightly on the section 
to confi rm it has completely locked into place.

Assemble Pipe Sections

Insert the inner fl ue of section A into the fl ared inner fl ue of 
section B.

Start the outer fl ue of section A over the outer fl ue of section 
B (see Figure 2.6). 

Note: 

The end of the pipe sections with the lances/tabs on 

it will face towards the appliance.

Once both inner and outer fl ues are started, press section 
A onto section B fi rmly until all lances have snapped into 
place. Check to make sure they have snapped together (see 
Figure 2.7)  and the seams are not aligned (see Figure 2.8). 
Tug slightly on section A to confi rm it has completely locked 
into place. 

For 90° and 45° elbows that are changing the vent direction 
from horizontal to vertical, one screw minimum should be 
put in the outer fl ue at the horizontal elbow joint to prevent 
the elbow from rotating.

Summary of Contents for BEK

Page 1: ...e assembly instructions See the appliance installation instructions for con guration of vent assembly and clearances to pipe If DVP AD adapters are used off the top of the appliance the termination he...

Page 2: ...0ST 90 elbow DVP WS wall shield with heat shield DVP TRAP1 termination cap with telescoping ue and one fastener pack DVP TRAPK2 Vent kit containing DVP90ST 90 elbow DVP WS wall shield with heat shield...

Page 3: ...in 6 in Slip Section Vent Pipe to be used with another piece of pipe DVP12A 3 in 12 in Slip Section Vent Pipe to be used with another piece of pipe DVP12MI 12 in Vent Pipe non unitized can be cut to l...

Page 4: ...0 7 8 in 6 3 4 in to 10 3 4 in GNTC50 5 in to 6 3 4 in 4 7 8 in to 6 5 8 in 7 3 8 in to 11 3 8 in 7 3 8 in to 11 3 8 in Designer 4 in to 5 3 4 in 5 3 4 in to 7 1 2 in 6 3 8 in to 10 3 8 in 8 1 8 in to...

Page 5: ...urations 2 Installing Vent Pipe B Penetrating a Wall Wherever a combustible wall is penetrated the hole must be framed with an interior wall shield DVP WS as shown in Figures 2 3 2 4 This shield maint...

Page 6: ...he pipe section into the appliance collar until all the lances see Fig ure 2 5 have snapped in place Tug slightly on the section to con rm it has completely locked into place Assemble Pipe Sections In...

Page 7: ...an then be attached by tting another pipe section to it and snapping it together as normal Assemble Slip Sections The outer ue of the slip section should slide over the outer ue of the pipe section an...

Page 8: ...e either section see Figure 2 14 so that the seams on both pipe sections are aligned see Figure 2 15 They can then be carefully pulled apart Figure 2 12 Securing Vertical Pipe Sections Figure 2 13 Sec...

Page 9: ...e cap in the same manner See Figure 2 16 If the wall thickness does not allow the required 1 1 2 in heat shield overlap an extended heat shield must be used The extended heat shield will need to be cu...

Page 10: ...17 Installing Firestop Spacer 3 fasteners per side Attic insulation shield installed below ceiling Attic insulation shield installed above ceiling Bend tabs in around pipe Figure 2 18 Installing the A...

Page 11: ...rom roof to lowest discharge opening 24 in min 610 mm Roof Pitch H Min Ft Roof Pitch H Min Ft Flat to 6 12 1 0 Over 11 12 to 12 12 4 0 6 12 to 7 12 1 25 Over 12 12 to 14 12 5 0 Over 7 12 to 8 12 1 5 O...

Page 12: ...ded through the brackets and tighten nut to complete the storm collar assembly see Figure 2 22 Make sure the collar is tight against the pipe section Slide the assembled storm collar down the pipe sec...

Reviews: