Hearth and Home Technologies BEK Installation Instructions Manual Download Page 1

Hearth & Home Technologies Inc. • Cinch Pipe & Term Caps • 4033-900 Rev K • 05/05

1

TM

TM

Models:
Cinch Pipe & Termination Cap System

Installation

 Instructions

If you need assistance during installation, contact your local dealer or the Technical Serices Dept., Hearth & Home Technologies 
Inc., phone 1-800-927-6841 or 1-888-427-3973.

Note: 

An arrow (

) found in the text signifi es change in content.

Sharp Edges

•  Wear protective gloves and safety glasses 

during installation.

CAUTION

These instructions are replacing  VP (for Heatilator) and  DV (for Heat-N-Glo) pipe assembly 
instructions. See the appliance installation instructions for confi guration of vent assembly 
and clearances to pipe.

If  DVP-AD adapters are used off the top of the appliance, the termination height will be raised by 2-3/4 in. overall 
height.

Hearth & Home Technologies disclaims any 
responsibility for, and the warranty will be 
voided by, the following actions:

• 

Installation and use of any damaged vent 
system component.

•  Modifi catoin of the vent system.
•  Installation other than as instructed by 

Hearth & Home Technologies.

• 

Installation and/or use of any component 
part not approved by Hearth & Home 
Technologies.

Any such action may cause a fi re hazard.

WARNING

Do not mix pipe, fittings or joining 
methods from different manufacturers.

WARNING

Summary of Contents for BEK

Page 1: ...e assembly instructions See the appliance installation instructions for con guration of vent assembly and clearances to pipe If DVP AD adapters are used off the top of the appliance the termination he...

Page 2: ...0ST 90 elbow DVP WS wall shield with heat shield DVP TRAP1 termination cap with telescoping ue and one fastener pack DVP TRAPK2 Vent kit containing DVP90ST 90 elbow DVP WS wall shield with heat shield...

Page 3: ...in 6 in Slip Section Vent Pipe to be used with another piece of pipe DVP12A 3 in 12 in Slip Section Vent Pipe to be used with another piece of pipe DVP12MI 12 in Vent Pipe non unitized can be cut to l...

Page 4: ...0 7 8 in 6 3 4 in to 10 3 4 in GNTC50 5 in to 6 3 4 in 4 7 8 in to 6 5 8 in 7 3 8 in to 11 3 8 in 7 3 8 in to 11 3 8 in Designer 4 in to 5 3 4 in 5 3 4 in to 7 1 2 in 6 3 8 in to 10 3 8 in 8 1 8 in to...

Page 5: ...urations 2 Installing Vent Pipe B Penetrating a Wall Wherever a combustible wall is penetrated the hole must be framed with an interior wall shield DVP WS as shown in Figures 2 3 2 4 This shield maint...

Page 6: ...he pipe section into the appliance collar until all the lances see Fig ure 2 5 have snapped in place Tug slightly on the section to con rm it has completely locked into place Assemble Pipe Sections In...

Page 7: ...an then be attached by tting another pipe section to it and snapping it together as normal Assemble Slip Sections The outer ue of the slip section should slide over the outer ue of the pipe section an...

Page 8: ...e either section see Figure 2 14 so that the seams on both pipe sections are aligned see Figure 2 15 They can then be carefully pulled apart Figure 2 12 Securing Vertical Pipe Sections Figure 2 13 Sec...

Page 9: ...e cap in the same manner See Figure 2 16 If the wall thickness does not allow the required 1 1 2 in heat shield overlap an extended heat shield must be used The extended heat shield will need to be cu...

Page 10: ...17 Installing Firestop Spacer 3 fasteners per side Attic insulation shield installed below ceiling Attic insulation shield installed above ceiling Bend tabs in around pipe Figure 2 18 Installing the A...

Page 11: ...rom roof to lowest discharge opening 24 in min 610 mm Roof Pitch H Min Ft Roof Pitch H Min Ft Flat to 6 12 1 0 Over 11 12 to 12 12 4 0 6 12 to 7 12 1 25 Over 12 12 to 14 12 5 0 Over 7 12 to 8 12 1 5 O...

Page 12: ...ded through the brackets and tighten nut to complete the storm collar assembly see Figure 2 22 Make sure the collar is tight against the pipe section Slide the assembled storm collar down the pipe sec...