HealthyAir Source Capture HA-SCV-G1-WD Owner'S Manual Download Page 2

I. Installation Notice

Read the Owner's Manual and Installation Instructions carefully. Failure to follow 
these instructions could cause a malfunction of the vent or unsatisfactory 
performance. Follow a regular service and maintenance schedule for efficient 
operation. 

For safety reasons, unplug the power cord from the electric outlet socket under 
the following conditions: 

When not in use for a long period of time

When cleaning

When moving the air purifier

II. Technical Specifications

Model Number 

HA-SVC-G1-WD 

Rated Voltage 

12V DC 

Power Consumption 

6W 

Weight 

4.4 lbs. (2 kg) 

Base Dimensions 

8”x4”x6” 

(200x100x150) 

III. Packaging Reference

The Source Capture Vent is shipped in one (1) package that contains the 
following contents:   

Source Capture Vent - Dual Unit

Power Adapter

Cover Plate (optional)

Flange (optional)

Summary of Contents for Source Capture HA-SCV-G1-WD

Page 1: ...fo aerovexsystems com 1 Model HA SCV G1 WD Source Capture Vent Dual Inlet Patent Pending Table of Contents Installation Notice 1 Technical Specifications 1 Packaging Reference 2 Component Reference 3...

Page 2: ...cord from the electric outlet socket under the following conditions When not in use for a long period of time When cleaning When moving the air purifier II Technical Specifications Model Number HA SV...

Page 3: ...To mount the Source Capture Vent cut an opening in table top or preferred mounting surface The dimensions of the cut out are 8 3 8 x 4 7 8 as shown in Fig 1 Fig 1 Cut Out Dimensions 5 2 To flush moun...

Page 4: ...er from bottom of the Source Capture Vent as shown in Fig 4 Fig 4 Remove Access Cover 7 V Installation Instructions 5 5 Install the Source Capture Vent in the table by inserting it into the cut out as...

Page 5: ...w be firmly installed in the table or mounting surface Fig 8 Source Capture Vent Installed 9 V Installation Instructions 5 9 Push the Pop Up Knobs down to release it as shown in Fig 9 Fig 9 Release Po...

Page 6: ...ly Using the Hex Nuts tighten and secure the Outlet Flange and the Blank Off Plate Finally reinstall the Access Cover Note that there are four types of Outlet Flanges available a Single Circular Outle...

Page 7: ...n be directly plugged into the LED Cord located in the inlet of the HealthyAir System Installation with HealthyAir Ceiling Mount System Note that the Source Capture Vent may also be integrated with th...

Page 8: ...e Housing Component 6 3 Turn the LED light on by pressing the On Off Switch located on the face on the Inlet Vent 6 4 Power on the HealthyAir Air Purification System to generate airflow and activate t...

Page 9: ...duct or part damaged by 1 accident misuse abuse or lack of reasonable care or normal maintenance 2 installation or operation under conditions other than those recommended by Healthy Air Inc 3 subjecti...

Reviews: