© 2020 HBX Controls
2
INSTALLATION AND WIRING
Mounting Instructions
In order to assure proper room temperature, it is important to identify the ideal
location of the thermostat. It should be approximately 5 feet from the floor
and at least 1 foot from door openings on an interior wall. Avoid exposing the
thermostat to direct sunlight, to air flows (doors, windows, etc.) as well as to
heat sources. Ensure the cavity that the thermostat will be installed in is well
insulated.
1 2 3
4
1 - 2:
External Room Sensor
3 - 4:
Aux Sensor
TH:
Communication
& Power from
ZON-0600
Use a screwdriver to gently pop the front cover off from the top of the thermostat, and
then remove the front to expose wiring terminals.
Do not use the screwdriver on the bottom of the thermostat. This can cause damage to
the THM-0600
External Room Thermistor
On the THM-0600, the room
thermistor switch is located on
the bottom left corner of the
thermostat.
Toggling this switch will allow the
user to alternate between the
built in room thermistor on the
THM-0600, or an external room
thermistor connected to pins 1 and
2 on the THM-0600.
INTERNAL ROOM
EXTERNAL ROOM