HBX THM-0300 Installation Manual Download Page 15

13

LIMITED WARRANTY

HBX Controls warrants each of its products to be free from defects in workmanship and materials 

under normal use and service for a period of 24 months from date of manufacture or 12 months 

from date of purchase from an HBX Authorized Dealer, if within the above documented period 

after date of manufacture.
If the product proves to be defective within the applicable warranty period, HBX on its sole 

discretion will repair or replace said product.  Replacement product may be new or refurbished of 

equivalent or better specifications, relative to the defective product.  Replacement product need 

not be of identical design or model.  Any repair or replacement product pursuant to this warranty 

shall be warranted for not less than 90 days from date of such repair, irrespective of any earlier 

expiration of original warranty period.  When HBX provides replacement, the defective product 

becomes the property of HBX Controls. 
Warranty Service, within the applicable warranty period, may be obtained by contacting your 

nearest HBX Controls office via the original Authorized Agent and requesting a Return Material 

Authorization Number (RMA #).  Proof of purchase in the form a dated invoice/receipt must be 

provided to expedite the issuance of a Factory RMA.
After an RMA number has been issued, the defective product must be packaged securely in 

the original or other suitable shipping package to ensure that it will not be damaged in transit.  

The RMA number must be visible on the outside of the package and a copy included inside the 

package.  The package must be mailed or otherwise shipped back to HBX with all costs of mailing/

shipping/insurance prepaid by the warranty claimant.
Any package/s returned to HBX without an approved and visible RMA number will be rejected and 

shipped back to purchaser at purchaser’s expense.  HBX reserves the right, if deemed necessary, 

to charge a reasonable levy for costs incurred, additional to mailing or shipping costs.

l

imitation

 

of

 w

arranties

If the HBX product does not operate as warranted above the purchasers sole remedy shall be, 

at HBX’s option, repair or replacement.  The foregoing warranties and remedies are exclusive 

and in lieu of all other warranties, expressed or implied, either in fact or by operation of law, 

statutory or otherwise, including warranties of merchantability and fitness for a particular purpose/

application.  HBX neither assumes nor authorizes any other person to assume for it any other liability 

in connection with the sale, installation maintenance or use of HBX Controls products.
HBX shall not be liable under this warranty; if its testing and examination discloses that the alleged 

defect in the product does not exist or was caused by the purchasers or third persons misuse, 

neglect, improper installation or testing, unauthorized attempts to repair or any other cause 

beyond the range of intended use, or by accident, fire, lightning or other hazard.

l

imitation

 

of

 l

iability

In no event will HBX be liable for any damages, including loss of data, loss of profits, costs of cover 

or other incidental, consequential or indirect damages arising out of the installation, maintenance, 

commissioning, performance, failure or interruption of an HBX product, however caused and on 

any theory of liability.  This limitation will apply even if HBX has been advised of the possibility of 

such damage.

l

ocal

 l

aw

This limited warranty statement gives the purchaser specific legal rights.  The purchaser may also 

have other rights which vary from state to state in the United States, from Province to Province in 

Canada and from Country to Country elsewhere in the world.
To the extent this Limited Warranty Statement is inconsistent with local law, this statement shall be 

deemed modified to be consistent with such local law.  Under such local law, certain disclaimers 

and limitations of this statement may not apply to the purchaser.  For example, some states in 

the United States, as well as some governments outside the United States (including Canadian 

Provinces), may: Preclude the disclaimers and limitations in this statement from limiting the statutory 

rights of a consumer (e.g. United Kingdom);

Otherwise restrict the ability of a manufacturer to enforce such disclaimers or limitations; or grant 

the purchaser additional warranty rights which the manufacturer cannot disclaim, or not allow 

limitations on the duration of implied warranties.

Summary of Contents for THM-0300

Page 1: ...HBX Control Systems Inc Installation Manual THM 0300 Programmable Thermostat Version 1 00 THM 0300...

Page 2: ...ith the codes and practices applicable to the jurisdiction for the actual installation The HBX THM 0300 is a microprocessor based controller and as such is not to be regarded as a safety limit control...

Page 3: ...r the THM 0300 screen to blink upon startup The THM 0300 has one external sensor input multiple heating cooling modes and can function as a digital setpoint aquastat Some features of the THM 0300 are...

Page 4: ...Special Functions screen by holding down the and buttons simultaneously for 5 seconds from the Status Screen To select the desired option use the and buttons to toggle and the set button to select 1 T...

Page 5: ...ES 5 ROOM OFFSET 0 F 6 C OR F F SPECIAL FUNCTIONS 2 Cool Heat Function Select the 2 Cool Heat Function for applications using 2 stage cooling and 1 stage heating 1 TYPE 2 COOL WITH HEAT 2 VIEW ALL YES...

Page 6: ...tback Allows you to program a setback A setback can be programmed to maximize energy during time frames where the zone may be vacant When you select YES you can program up to 4 setback time period 1 T...

Page 7: ...ws the user to return to the previous screen START HEAT 1 6 00A 74 F 2 8 00A 64 F 3 4 30P 72 F 4 9 00P 90 F 5 BACK WEEKDAY PROGRAMS Weekend Programs Adjust four time periods within the two weekend pro...

Page 8: ...ur zone If the temperature in the zone increases above this temperature cooling will come on Changeover Auto this option allows you to change automatically from heat mode to cool mode or vice versa He...

Page 9: ...ding feedback for both the air temperature and floor sensor temperatures Only available when heating modes are the primary function Dual Mode Floor Maximum The thermostat will not allow the temperatur...

Page 10: ...erential around the target to lesson the chances of short cycling MODE SETUP 1 MODE FLOOR 2 DIFF 5 F 3 SENSOR 1 FLOOR Floor Mode Sensor 1 This option will be automatically set to floor sensor MODE SET...

Page 11: ...et a priority on a zone s over other zone s Priorities range from 1 highest to 8 lowest Higher priorities will lock out lower priorities until the demand has been satisfied Multiple zones can be given...

Page 12: ...on the fancoil FANCOIL SETUP 1 FAN ON DMD NO 2 ZONE ON DMD NO 3 TEMP AVE NONE 4 FAN MODE OFF Fancoil Setup Fan Mode OFF Indicated Fan is off ON Enables the fan to run constantly regardless of whether...

Page 13: ...HEDULE 2 MODE 3 SYSTEM SETUP 4 TIME Time Setup This setting takes you to the Time Setup Menu Time Setup Time Set the time for your appropriate time zone TIME SETUP 1 TIME 1 00pm 2 DAY OF WEEK MON 3 TI...

Page 14: ...ng the thermostat to direct sunlight to air flows doors windows etc as well as to heat sources Wiring Examples To ZON 0550 THM 0300 HBX 3 COMM 6 5 3 TH 2 TH 4 3 2 Thermostat 1 2 1 1 DO NOT CONNECT POW...

Page 15: ...on repair or replacement The foregoing warranties and remedies are exclusive and in lieu of all other warranties expressed or implied either in fact or by operation of law statutory or otherwise inclu...

Page 16: ...V1 02...

Reviews: