background image

9

1 2

3 4 5

6

1 - 2:

  Dry Contact Output

3 - 4:

  External Thermistor

5 - 6:

  10-24V AC or DC

WIRING DIAGRAMS

Wiring Guide                                                                                                                                      

1. H

EATING

7+0

HBX

2

24V AC

6

5

2

TH

2

TH

4

3

3

7KHUPRVWDW

RL

1

RL

2

1

1

2 A

DO NOT 

CONNECT

 POWER HERE

v

W

R C

Transformer

24VAC

7+0

HBX

2

24V AC

6

5

2

TH

2

TH

4

3

3

7KHUPRVWDW

RL

1

RL

2

1

1

2 A

DO NOT 

CONNECT

 POWER HERE

v

R C

Transformer

24VAC

Dry Contact 

Output

Summary of Contents for THM-0100

Page 1: ...HBX Control Systems Inc Installation Manual THM 0100 Setpoint Thermostat Version 1 041 THM 0100 ...

Page 2: ... jurisdiction for the actual installation The HBX THM 0100 is a microprocessor based controller and as such is not to be regarded as a safety limit control Please consult and install the heating or cooling appliance in accordance with the manufacturer s recommendations SAFETY SYMBOLS AND WARNINGS DRAWING REFERENCE of the manual PRECAUTION A measure taken in advance to prevent dangerous or an unple...

Page 3: ...d for single 673787 7 temperature sensing The THM 0100 can be used as a single setpoint control allowing for the operation of DHW Digital Aquastat pumps and other equipment Some features of the THM 0100 are 6 3 3 Technical Data 1 x Dry Contact Output 1 x External Thermistor Input 6 G 8 Dimensions 115 x 80 x 27 5mm ETL Listings Meets CSA C22 2 No 24 L Q UVY Z L 7 Y U GY Storage 10C to 40C Languages...

Page 4: ...pecial Functions Enter the Special Functions screen by holding down the and buttons simultaneously for 5 seconds from the Status Screen To select the desired option use the and buttons to toggle and the set button to select 1 Type Select between Heating Cooling and Setpoint modes Heat Function Select the Heat Function for applications using a single heating source See diagram 1 for wiring examples...

Page 5: ...e arrow to the left of your chosen option will turn black and buttons to adjust the value Press the SET button to scroll between options again 72 0 F ROOM FLOOR 79 F TARGET 72 F HEAT 72 0 F 10 00am ROOM _ z _ _ _ No external sensor installed 72 0 F 10 00am ROOM FLOOR 79 F TARGET 72 F HEAT 72 0 F ROOM _ _ _ _ 10 00am Setpoint TARGET 198 F COOLING ADJUSTMENT 1 ROOM 70 F 2 SENSOR 1 FLOOR 3 C OR F F 4...

Page 6: ...ENT 1 ROOM TEMP 70 F 2 MODE ROOM 3 SENSOR 1 NONE 4 C OR F F 5 BACKLIGHT OFF 6 TIME 1 05am Room Mode Sensor temperature providing feedback for the thermostat Sensor 1 Only Applies in Room Mode Enable the feedback sensor as None Room Floor Outdoor or Room Average in Floor mode None No external sensor is connected to the Thermostat Room The external sensor is used to control the room temperature Floo...

Page 7: ...4 FLOOR MIN 65 F 5 C OR F F 6 TIME 1 05am Floor Maximum Only Applies in Dual Mode The thermostat will not allow the temperature in the 7 HEATING ADJUSTMENT 1 ROOM TEMP 70 F 2 MODE DUAL 3 FLOOR MAX 85 F 4 FLOOR MIN 65 F 5 C OR F F 6 TIME 1 05am Floor Minimum Only Applies in Dual Mode The thermostat will not allow the temperature in the 7 HEATING ADJUSTMENT 1 ROOM TEMP 70 F 2 MODE DUAL 3 FLOOR MAX 8...

Page 8: ...n after selecting Cool Room Temperature Set this value to the desired room target Range from 32 F to 200 F COOLING ADJUSTMENT 1 ROOM 70 F 2 SENSOR 1 FLOOR 3 C OR F F 4 BACKLIGHT OFF 5 TIME 1 05am Sensor 1 Enable the feedback sensor as None Room Floor Outdoor or Room Average in Floor mode None No external sensor is connected to the Thermostat Room The external sensor is used to control the room tem...

Page 9: ...USTMENT SETTINGS The Setpoint Adjustment screen is applicable to the Setpoint option selected in the special functions screen Enter the Setpoint Adjustment screen by holding the SET button after selecting Setpnt Setpoint Set this value to the desired setpoint target SETPOINT ADJUSTMENT 1 SETPOINT 130 F 2 MODE HEAT 3 DIFF 20 F 4 LAG TIME 0S 5 C OR F F 6 TIME 1 05am Mode Select between Heat mode or ...

Page 10: ...heit SETPOINT ADJUSTMENT 1 SETPOINT 130 F 2 MODE HEAT 3 DIFF 20 F 4 LAG TIME 0S 5 C OR F F 6 TIME 1 05am Time Q 7 SETPOINT ADJUSTMENT 1 SETPOINT 130 F 2 MODE HEAT 3 DIFF 20 F 4 LAG TIME 0S 5 C OR F F 6 TIME 1 05am MOUNTING AND WIRING INSTRUCTIONS Mounting Guide Once you have wired the terminal block the THM 0100 can be mounted on the desired interior wall The unit should be placed in an area clear...

Page 11: ...NG DIAGRAMS Wiring Guide 1 HEATING 7 0 HBX 2 24V AC 6 5 2 TH 2 TH 4 3 3 7KHUPRVWDW RL 1 RL 2 1 1 2 A DO NOT CONNECT POWER HERE v W R C Transformer 24VAC 7 0 HBX 2 24V AC 6 5 2 TH 2 TH 4 3 3 7KHUPRVWDW RL 1 RL 2 1 1 2 A DO NOT CONNECT POWER HERE v R C Transformer 24VAC Dry Contact Output ...

Page 12: ...7KHUPRVWDW RL 1 RL 2 1 1 2 A DO NOT CONNECT POWER HERE v 2 COOLING 7 0 HBX 2 24V AC 6 5 2 TH 2 TH 4 3 3 7KHUPRVWDW RL 1 RL 2 1 1 2 A DO NOT CONNECT POWER HERE v Y R C Transformer 24VAC 7 0 HBX 2 24V AC 6 5 2 TH 2 TH 4 3 3 7KHUPRVWDW RL 1 RL 2 1 1 2 A DO NOT CONNECT POWER HERE v R C Transformer 24VAC Dry Contact Output ...

Page 13: ...11 NOTES ...

Page 14: ... 2014 HBX Controls 12 NOTES ...

Page 15: ...or costs incurred additional to mailing or shipping costs LIMITATION OF WARRANTIES If the HBX product does not operate as warranted above the purchasers sole remedy shall be at HBX s option repair or replacement The foregoing warranties and remedies are exclusive and in lieu of all other warranties expressed or implied either in fact or by operation of law 7 in connection with the sale installatio...

Page 16: ... 7 ...