INSTALL

02

01

03

04

Summary of Contents for 6A Series

Page 1: ...V1 0 Easy touch Easy warm Thermostat Instruction INSTALL 02 01 03 04 03 ...

Page 2: ...hooting 10 Dimension 08 Function and Operation 02 Technical Specifications Table of Contents 01 01 05 01 02 03 04 07 13 14 8 1 Temporary Override Temperature 8 2 Mode 8 3 Key Lock 8 4 1 Clock 07 07 09 08 8 4 2 Event Setting 8 4 3 Readout 8 4 4 Advanced Setting 8 5 Open Window detection 8 4 Menu 09 10 12 07 10 APP for ET 6AW ...

Page 3: ...the screws through the holes in each side of the thermostat Put the frame on Click the display module back in place Press your fingers under the side of the front part and pull toward you Step 1 Step 2 Step 3 Step 4 Suggestion Please keep the max load around 90 of 16A to prolong the lifetime Suggestion Please keep the max load around 90 of 16A to prolong the lifetime WIRING INSTRUCTION MAX LOAD 16A...

Page 4: ...uilt in room sensor 02 Room in sensor and floor sensor run by built in sensor with floor temp limit 03 Room out sensor run by external room sensor 04 Room out sensor and floor sensor run by external room sensor with floor temp limit Floor temp limit If you choose Both sensors If you choose room sensor and floor sensor floor temp limit must be set to protect floor Home or office Home Office There are 5 option...

Page 5: ...1 Scan the QR code through a browser or download the APP from the major application markets to install it Step 2 Click the APP log in through the registered phone number or email address Step 4 Check the thermostat WiFi flag is fast flashing if not operate the thermostat according to the APP tips until it flashes quickly Click the Make sure WiFi is flashing quickly button Step 6 Click Done after the A...

Page 6: ...ce press and hold the and for 3 seconds at the same time to lock or unlock all of the keys 8 3 Key Lock n the actual temp interface Press the and to set temporary n the actual temp interface Press the and to set temporary n the actual temp interface Press the to select the mode press and hold the and for 3 seconds at the same time to lock or press and hold the and for 3 seconds at the same time to...

Page 7: ...ed settings to suit various special situations These are normally set by technicians during initial installation On the clock interface press the or to select SET Press the to enter advanced setting Each setting can be accessed by pressing and parameters adjusted by pressing or 09 10 8 4 3 Readout 8 4 4 Advanced Setting Press the or to set day Press the or to set day Press the to enter day setting...

Page 8: ...unction only works when room sensor or both sensor is selected refer to 6 2 The thermostat with this function will shut off automatically for 15 mins when the window opens as it can detect that the room temp plummets Parameter 2 Room temp calibration calibrate the temp detected by room sensor 3 Floor temp calibration calibrate the temp detected by floor sensor 4 Floor temp limit if you choose both s...

Page 9: ...TROUBLESHOOTING TROUBLESHOOTING E1 Room in sensor error E2 Floor sensor error E4 Room out sensor error 86 86 59 51 52 24 9 12 13 14 DIMENSION MM ...