CDM 3201 Order No. BA 92-12-3321A Issue 19.09.08
45
5.7.3
Charging Monitoring (Ready)
A charging monitoring is provided to carry out an optimum control of the time sequence
of PLC machines. If the power unit is ready for welding, a transistor will be switched on
(control sleeve, 4 poles, Pin 1; 4).
Operating voltage 24 V DC
Current capacity max. 50 mA
5.7.4
Contact
To control the sequence of PLC machines at best, an external contact inquiry is provided
between workpiece and welding head. If contact is signalled, the transistor is switched
on (control sleeve 3 poles, Pin 1; 3).
Operating voltage 24 V DC
Current capacity max. 50 mA
Operation of the automatic welding head KAH 412 (see opera-
ting manual).
5.7.5
RS232 Interface
Via the serial interface of the power unit, the actually recorded data can be output for
a potential storage in ASCII format.
A data cable is required which can be ordered as a consumable at HBS
(order no. 80-70-308).
Example for data output at serial output (e.g. Microsoft® Hyper Terminal)
Output s eria l interfac e CDM units
No.
D ate
Tim e
Prg./
Libr.-Mode
Prg.-
N o.
Charging
voltage
Capacity Mode
Lock
Range
R ef.-
PAF
PAF Status
52
20.03.2004 09:30
PRGM
P1
150V
1
R
ON
5
3500 3612
OK
53
20.03.2004 09:31
PRGM
P1
150V
1
R
ON
5
3500 4100
ER R
54
20.03.2004 09:32
PRGM
P1
150V
1
R
ON
5
3500 3246
OK
This data collection can be evaluated by a terminal program (e.g. Hyper Terminal) (see
appendix: Hyper Terminal).
Connection settings of the serial interface at a PC or notebook:
Bits per second:
19.200
Data bits:
8
Parity:
none
Stop bits:
1
5 Stud Welding Procedure
5.7 Welding Procedure
Summary of Contents for CDM 3201
Page 1: ...CDM 3201 Power Unit Automatic Version 92 12 3321A Operating Manual...
Page 8: ...viii CDM 3201 Order No BA 92 12 3321A Issue 19 09 08 Table of Contents...
Page 87: ...CDM 3201 Order No BA 92 12 3321A Issue 19 09 08 87 Service Support Service Support...
Page 92: ...92 CDM 3201 Order No BA 92 12 3321A Issue 19 09 08...
Page 93: ......