CDM 3201 Order No. BA 92-12-3321A Issue 19.09.08
33
5.6.2
Setting the Stud Feed Time (Automatic Mode)
In automatic mode, you can set the blow time (stud feeding time) of VBZ and the piston.
The blow time can be set between 50 ms and 5,000 ms.
Press the arrow key
until the sign „>“ is dislayed in front of „Automatic“.
⇒
use the enter key
>Automatic Mode
Control Language
to open the menu item „Automatic“.
With the keys
or
>Automatic On
Blow time: xxx mS
you can switch on or
off the automatic function.
Now use the arrow key
to
Automatic On
>Blow time: xxx mS
select the menu item ‘blow time’.
Set the blow time with the keys
or
.
5.6.3
Adjusting the Modes
You can select between program and library mode.
Program mode
In program mode, 8 storage places are available. You can assign and call-up an
individual charging voltage to each place.
Program selection
Press the arrow key
until
the sign ">" appears to the left of "P x"
>P5 150 V
⇒
select the program with
or
Progam number: 1 to 8
Select charging voltage
Press the arrow key
until
the sign ">" appears to the left of "xxx V".
P5 >150 V
⇒
increase charging voltage with
⇒
decrease charging voltage with
Charging voltage: 50 V to 220 V
5 Stud Welding Procedure
5.6 Switching on the Power Unit
Summary of Contents for CDM 3201
Page 1: ...CDM 3201 Power Unit Automatic Version 92 12 3321A Operating Manual...
Page 8: ...viii CDM 3201 Order No BA 92 12 3321A Issue 19 09 08 Table of Contents...
Page 87: ...CDM 3201 Order No BA 92 12 3321A Issue 19 09 08 87 Service Support Service Support...
Page 92: ...92 CDM 3201 Order No BA 92 12 3321A Issue 19 09 08...
Page 93: ......