Compressed Air Connection for Automatic Stud Feeding
If you use the automatic stud feeding unit, put the air hose of the compressed air
supply (6 bar, 800 l/min) into the feeder unit VBZ-3.
Connect the compressed air outlet of the feeding unit to the compressed air inlet
of the power unit.
An operating pressure of max. 6 bars can be set with the
pressure reduction valve of the feeding unit. The filter unit
cleans and drains the compressed air.
Rear view
3.6
Change Working Place
Switch off the power unit. In this way, you avoid any risk of
electrical shock.
When you move your workplace, disconnect the welding gun and the ground
cables from the power unit. Proceed in reversed sequence as described in
section 3.2, 3.3, 3.4 and 3.5.
After changing the workplace, check the welding gun and the ground cables for
possible damage or missing components.