WE2107
36
A2087-1.3 en/de
HBM
10
WE2107 - Complete menu structure
Main menu
2nd level 3rd level Sub‐menu explanation
InFo
VAL
CALC
Legal for trade counter
tArE
Current tare value
ZEro
Zero value
totAL
Total weight
FILL
Filling result
Sv_nb
Software version (7x, x = 0...9)
F_nb
WE2107 production number
Error
AdC
ADC Overflow counter
SEnS
Sensor Overflow counter
Error
Last error code: Er xxx
rESLt
Prt
Print protocol Prt_1...9 (when UArt2 = P_...selected), OM, Page 88
PAr
ALL
Print out all parameters
SEtPt
LS_1
InPut
OFF/NET/GROSS
LEvEL
truE / InvErt
oFF_L
OFF level: +- 99999
on_L
ON level: +-99999
LS_2
InPut
OFF/NET/GROSS
LEvEL
truE / InvErt
OFF_L
OFF level: +- 99999
On_L
ON level: +-99999
LS_3
InPut
OFF/NET/GROSS
LEvEL
truE / InvErt
OFF_L
OFF level: +- 99999
On_L
ON level: +-99999
LS_4
InPut
OFF/NET/GROSS
LEvEL
truE / InvErt
OFF_L
OFF level: +- 99999
On_L
ON level: +-99999
FiLL
doS_t
Maximum dosing time: 0=OFF; 1...99999 x 0.1s
EtY_t
Emptying time: 0=OFF; 1...99999 x 0.1s
rES_t
Residual flow time: 0=OFF; 1...99999 x 0.1s
tAr_t
Tare time: 0=OFF; 1_99999 x 0.1s
SEtuP
FILt1
0 = standard, 1 = fast, 2...4 = tier filter (OM, Page 65)
FILt2
0 _ 8 limit frequencies, depending on filter type FILt1 (OM, Page 48)
PtArE
Manual tare value: 0=OFF; 1= 1...Maximum capacity CAP
count
nb
Counting scale reference number of pieces: 0=OFF; 1...999
pieces=ON
UArt1
Addr
Network address: 0_31
bAudr
Baud rate: 1200 / 2400 / 4800 / 9600 / 19200 / 38400 baud
PArit
Parity bit: nonE (no parity), EvEn (even parity)
UArt2
Funct
OFF / P_dtr / P_dc1 / E_no / E_dtr / E_dc1 (OM, Page 50)
bAudr
Baud rate: 1200 / 2400 / 4800 / 9600 / 19200 / 38400 baud
PArit
Parity bit: nonE (no parity), EvEn (even parity)
EdSPL
St_Ch
Ext display ON (when UArt2 = E_...): Start character 0...31 (0=OFF)
Prot
Protocol selection: 0...7 (OM, Page 51)
E_Ch1
End character 1: 0...31 (0=OFF)
E_Ch2
End character 2: 0...31 (0=OFF)
CrC
Checksum: OFF/ON