![HBK TIM-PN Mounting Instructions Download Page 39](http://html.mh-extra.com/html/hbk/tim-pn/tim-pn_mounting-instructions_2111673039.webp)
37
TIM-PN
SETTINGS
If, for instance, the torque value is incorrect (e.g. actual value > 120% of the rated value or
transmission error between rotor and stator), then the output will conform to what you
have set under error specification. If you selected Overflow, the torque value will change
to 7FFFFFFFh in the case of an error.
For how long the error should be signaled on the PROFINET interface can be set manu
ally, or automatically determined by the system.
If you select automatic, the error duration for dynamic errors will be specified subject to
the set filter. Static errors are displayed until they are rectified.
Filter
Failure flag duration on PROFINET
3 kHz
520
μ
s
1 kHz
1.235 ms
100 Hz
10.9 ms
10 Hz
130 ms
1 Hz
975 ms
0.1 Hz
27 s
Table of errors in torque
CRC5 failure in
sequence
[dynamic]
During transmission from the torque transducer to TIM-PN, a
CRC error is detected in more than 5 values in direct sequence
(otherwise the preceding, old, correct value is taken)
Measured value not
sent (stator has
detected failures or
transmission is
defective)
[dynamic]
If a measured value is not sent at all, the failure state must be
assumed immediately. If the stator can be accessed, the
device failures are also updated.
Linearization failure
[static]
Linearization is active, but the rotor serial number is different
to that in the TIM-PN device.
Measured value
overflow or underflow
[dynamic]
The limit for T40 is +/- 120% of the nominal (rated) torque.
Summary of Contents for TIM-PN
Page 1: ...TIM PN ENGLISH DEUTSCH FRANÇAIS Mounting Instructions Montageanleitung Notice de montage ...
Page 3: ...TIM PN ENGLISH DEUTSCH FRANÇAIS Mounting Instructions ...
Page 62: ...TIM PN SETTINGS 60 Fig 10 32 Service File ...
Page 73: ...71 TIM PN PROFINET CONFIGURATION WITH THE TIA PORTAL ...
Page 87: ...TIM PN ENGLISH DEUTSCH FRANÇAIS Montageanleitung ...
Page 148: ...TIM PN EINSTELLUNGEN 62 Abb 10 32 Service File ...
Page 160: ...TIM PN PROFINET KONFIGURATION MIT DEM TIA PORTAL 74 ...
Page 173: ...87 TIM PN TECHNISCHE DATEN Abb 14 1 Abmessungen ...
Page 174: ...TIM PN TECHNISCHE DATEN 88 ...
Page 175: ...TIM PN ENGLISH DEUTSCH FRANÇAIS Notice de montage ...
Page 238: ...TIM PN RÉGLAGES 64 Fig 10 32 Service File Fichier de service ...
Page 262: ...TIM PN CARACTÉRISTIQUES TECHNIQUES 88 Fig 14 1 Dimensions ...
Page 263: ...89 TIM PN CARACTÉRISTIQUES TECHNIQUES ...
Page 264: ...HBK Hottinger Brüel Kjaer www hbkworld com info hbkworld com A04341 06 Y00 00 7 0103 0003 ...