9. Troubleshooting
The Classic²/Highpower² does not mist
1.
Check external control
2.
Check power source
3.
Check fluid quantity
4.
Check connection at fluid tank for tightness
5.
Check suction strainer in tank for contamination
6.
Check fluid hose and connector for tightness
The Classic²/Highpower² hums loudly when fogging
1.
The pump runs dry. This must be avoided at all costs.
2.
Refill fluid
3.
Check hose and coupling, engage again if necessary.
The Classic²/Highpower² shows the error message "machine too hot" in the
display
●
The temperature inside the device is too high. After cooling down, the error
disappears again.
The Classic²/Highpower² shows the error message "thermocouple broken"
in the display
●
One of the thermocouples is broken. The machine switches off for safety
reasons.
17