background image

 

 

 

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 

Page 6 of 36 

Super Pump VS Pump 

IS2603VSP  Rev-A 

 

 

WARNING

 – To Reduce the risk of Entrapment Hazards: 

 

When outlets are small enough to be blocked by a person, a minimum of two functioning suction outlets per 
pump must be installed.  Suction outlets in the same plane (i.e. floor or wall), must be installed a minimum of 
three feet (3’) [0.91 meter] apart, as measured from near point to near point. 

 

Dual suction fittings shall be placed in such locations and distances to avoid “dual blockage” by a user. 

 

Dual suction fittings shall not be located on seating areas or on the backrest for such seating areas. 

 

The maximum system flow rate shall not exceed the values shown in the “Pipe Sizing Chart” found in section 
4.3 below. 

 

Never use pool or spa if any suction outlet component is damaged, broken, cracked, missing, or not securely 
attached. 

 

Replace damaged, broken, cracked, missing, or not securely attached suction outlet components 
immediately. 

 

In addition to two or more suction outlets per pump installed in accordance with latest APSP standards and 
CPSC guidelines, follow all national, state, and local codes applicable. 

 

Installation of a vacuum release or vent system, which relieves entrapping suction, is recommended. 

 

WARNING

 

– Hazardous Pressure.

  Pool and spa water circulation systems operate under hazardous 

pressure during start-up, normal operation, and after pump shut-off.  Stand clear of circulation system equipment 
during pump start-up.  Failure to follow safety and operation instructions could result in violent separation of the 
pump housing and cover due to pressure in the system, which could cause property damage, severe personal injury, 
or death.  Before servicing pool and spa water circulation system, all system and pump controls must be in off 
position and filter manual air relief valve must be in open position.  Before starting pump, all system valves must be 
set in a position to allow system water to return back to the pool.  Do not change filter control valve position while 
pump is running.  Before starting pump, fully open filter manual air relief valve.  Do not close filter manual air relief 
valve until a steady stream of water (not air or air and water mix) is discharged from the valve.  All suction and 
discharge valves MUST be OPEN when starting the circulation system.  Failure to do so could result in severe 
personal injury and/or property damage. 

 

WARNING

 – Separation Hazard.

  Failure to follow safety and operation instructions could result in violent 

separation of pump components.  Strainer cover must be properly secured to pump housing with strainer cover lock 
ring.  Before servicing pool and spa circulation system, all system and pump controls must be in off position and 
filter manual air relief valve must be in open position.  Do not operate pool and spa circulation system if a system 
component is not assembled properly, damaged, or missing.  Do not operate pool and spa circulation system unless 
filter manual air relief valve body is in locked position in filter upper body.  All suction and discharge valves MUST be 
OPEN when starting the circulation system.  Failure to do so could result in severe personal injury and/or property 
damage. 

 

WARNING

 – Never operate the circulation system at more than 50 PSI maximum. 

 

WARNING

 

– Fire and burn hazard.

  Motors operate at high temperatures and if they are not properly 

isolated from any flammable structures or foreign debris they can cause fires, which may cause severe personal 
injury or death.  It is also necessary to allow the motor to cool for at least 20 minutes prior to maintenance to 
minimize the risk for burns. 

 

WARNING

 – Failure to install according to defined instructions may result in severe personal injury or 

death. 

 

                     

SAVE THESE INSTRUCTIONS

 

Summary of Contents for Super Pump VS SP2603VSP

Page 1: ...ermanent magnet motor Super Pump VS is easily installed either as a programmable stand alone pump or with a Hayward or third party controller and features an easy to use digital control interface that...

Page 2: ...Procedure 14 5 Wiring Diagrams 15 5 1 Input Power Wiring Required 15 5 2 Wall Mounted Digital Control Interface Wiring Optional 15 5 3 External Relay Speed Control Wiring Optional for remote selection...

Page 3: ...3 Removing the Ceramic Seat 27 9 4 Seal Installation 27 9 5 Replacing the Impeller and Diffuser 27 9 6 Replacing the Motor Assembly 28 10 Replacement Parts 28 10 1 Parts Diagram 28 10 2 Parts Listing...

Page 4: ...l Electric Code NEC USE OF NON HAYWARD REPLACEMENT PARTS VOIDS WARRANTY ATTENTION INSTALLER THIS MANUAL CONTAINS IMPORTANT INFORMATION ABOUT THE INSTALLATION OPERATION AND SAFE USE OF THIS VARIABLE SP...

Page 5: ...ARNING Failure to bond pump to pool structure will increase risk for electrocution and could result in injury or death To reduce the risk of electric shock see installation instructions and consult a...

Page 6: ...be in off position and filter manual air relief valve must be in open position Before starting pump all system valves must be set in a position to allow system water to return back to the pool Do not...

Page 7: ...ced hydraulic design Fully programmable with a self contained 24 hour clock and up to 8 custom speed and timer functions For enhanced pool management can be controlled by Hayward or third party pool a...

Page 8: ...ce every 24 hours Check with local requirements for the minimum turnover rate Running the pump at a lower speed may require running the pump for a longer period of time in order to meet the turnover r...

Page 9: ...ARNING Hazardous Pressure Pumps filters and other equipment components of a swimming pool filtration system operate under pressure Incorrectly installed and or improperly tested filtration equipment a...

Page 10: ...required by code Connect ground terminal to electrical service ground 3 Bond pump to pool structure Bonding will connect all metal parts within and around the pool with a continuous wire Bonding redu...

Page 11: ...e section 5 3 for more information regarding connecting Super Pump VS and third party non software compatible Hayward controls 3 Super Pump VS can communicate with and be controlled by Hayward pool an...

Page 12: ...he W S485 terminal tion The cabl t provided on ed for the cabl Figure 4 12 4 wall mount pla plate taking re DR9 on the mo ure 4 12 3 esume norma interface wal moving the Dig GENUINE RE Pump VS Pu part...

Page 13: ...12 2 Re USE ONLY H emoving the I F HAYWARD G Super P nterface Mou igure 4 12 3 A GENUINE RE Pump VS Pu unting Plate to Adding the Bl PLACEMENT ump o access the D lank Cover T PARTS Drive wiring co IS...

Page 14: ...elay contacts as shown in the External Relay Speed Control Wiring diagram See section 5 3 6 If the installation will use the remote stop feature of the drive connect the digital input terminals to the...

Page 15: ...ce Wiring Optional Figure 5 2 1 Connection wire must be rated for a minimum of 300V and may be up to 500 feet in length Use removable 4 position terminal block connectors for wiring connection to inte...

Page 16: ...ing relay contacts to select the speeds set in the Timer Menu see section 6 7 In addition to this section you may also consult the applicable pool control installation manual for electrical connection...

Page 17: ...otor drive PCB taking care to note the wire colors and corresponding numbers next to the connectors Terminal block must be installed with screws facing up to ensure proper connection When communicatin...

Page 18: ...d the SW200 DIP switch 1 must be ON 6 Startup Operation 6 1 Prior to Start Up If it is necessary to perform a water pressure test prior to initial use to ensure plumbing system is functioning properly...

Page 19: ...or ATTENTION Do NOT add chemicals to pool spa system directly in front of pump suction Adding undiluted chemicals may damage pump and voids warranty ATTENTION Before removing strainer cover 1 STOP PUM...

Page 20: ...hrough the setup menus when pressed The and arrow buttons are used to move between displays and to select parameters to edit and the and arrow buttons are used to change parameters 3 Status LEDs The C...

Page 21: ...uals 1 through 4 c Speed X Speed where X equals 1 through 4 4 Diagnostics Menu see section 6 9 to view product diagnostic information a Display Firmware Revision b Drive Serial Number c Motor Drive Fi...

Page 22: ...30 second increments 10 Select Stand Alone or Relay Control Move to next menu item Note See section 5 3 for more detail 11 Enable or Disable Low Temp Operation Move to next menu item 12 Set temperatu...

Page 23: ...s are to run 7 days per week 5 days per week Monday thru Friday or on a single day Monday thru Sunday Each timer is set up in this same manner When the pump is powered and the timers are set up the Ti...

Page 24: ...d without entering the Speeds Menu using the and arrow buttons to change the speed and then pressing the button to save the new speed setting 6 9 Diagnostic Menu Buttons Screen Used Comments 1 Use to...

Page 25: ...operation the above message will be displayed The pump will stop within several seconds and will remain stopped until Stop Resume is pressed a second time at which point the pump will resume normal o...

Page 26: ...volume blower when air purging the pump filter or piping ATTENTION Allowing the pump to freeze with water in it will void the warranty ATTENTION Use ONLY propylene glycol as antifreeze in your pool sp...

Page 27: ...expose the impeller 9 2 Removing the Impeller 3 To prevent the motor shaft from turning secure using a 5 16 hex wrench on the motor shaft through the fan shroud on the back of the pump 4 Remove the im...

Page 28: ...isturb the diffuser gasket 14 Fasten assembly to pump strainer housing using the four 4 3 8 x 2 bolts Be sure housing gasket is in place and lubricated Replace if damaged Tighten bolts alternately and...

Page 29: ...X1600F5 Motor Mounting Plate 1 14 SPX0125z44 Motor Cap Screws Set of 4 1 15 SPX1600Z4 Housing Cap Screw 4 16 SPX2600G1 Mounting Foot Includes Screws 1 17 SPX1600Z52 Mounting Foot Screws Set of 2 1 18...

Page 30: ...asket loaded with debris Remove the strainer housing cover or the skimmer cover Clean the basket and refill the strainer housing with water Tighten the cover 5 Suction side clogged Contact a qualified...

Page 31: ...to the equipment pad 3 Foreign matter in the pump housing Loose stones debris hitting the impeller could be the cause Clean the pump housing 4 Motor bearings noisy from normal wear rust overheating o...

Page 32: ...ical Service for additional assistance Check System Processor failed Indicates that there is a problem with the processor in the motor drive and that the motor drive may need to be replaced Contact Ha...

Page 33: ...IS2603VSP Rev A DATE OF INSTALLATION ____________________ INITIAL PRESSURE GAUGE READING CLEAN FILTER _______________________ PUMP MODEL __________________ 12 Warranty 13 Product Registration Retain t...

Page 34: ...USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Page 34 of 36 Super Pump VS Pump IS2603VSP Rev A THIS PAGE INTENTIONALLY LEFT BLANK...

Page 35: ...USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Page 35 of 36 Super Pump VS Pump IS2603VSP Rev A THIS PAGE INTENTIONALLY LEFT BLANK...

Page 36: ...__________________________ Type of Pool Concrete Gunite Vinyl Fiberglass Other_____________________________ New Installation Replacement Installation for In Ground Spa FCC Compliance Statement This de...

Reviews: