USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 

 

 

7

 

 
 
 

 

To prevent unnecessary strain on piping system and valves, always shut off pump before switching Filter 

Control Valve positions. 

 

FILTER CONTROL VALVE FUNCTIONS 

Six-Position Vari-Flo

TM

 Filter Control Valve SP0710XR50 or SP0715XR50 

(A)

 

FILTER – Set valve to FILTER for normal filtering.  Also use for regular Vacuuming. 

(B)

 

BACKWASH –  

a.

 

Shut off the pump. 

b.

 

Set Filter Control Valve to BACKWASH.   

c.

 

Start Pump and backwash approximately two minutes, or until water out waste line appears clean. 

d.

 

Shut off pump. 

e.

 

Set Control Valve to RINSE. 

f.

 

Start pump and operate for 20 seconds. 

g.

 

Shut off pump. 

h.

 

Set Filter control valve to FILTER. 

i.

 

Proceed as in Pre-Coating to add fresh D.E. 

(C)

 

RINSE – Water Flows through the filter the same as in FILTER position, except that the water goes to WASTE.  An optimal position 

used for pre-coating if a large cloud (pre-coat puff) is observed returning to pool during the pre-coating process. 

(D)

 

WASTE – To bypass filter for draining or lowering water level and for vacuuming heavy debris directly to WASTE. 

(E)

 

RECIRCULATE – Water is re-circulated through the pool system, bypassing the filter. 

(F)

 

CLOSED – Shuts off flow from pump to filter. 

Four Position Selecta-Flo

TM

 Filter Control Valve SP0740DE or SP0425 

(A)

 

FILTER– Set valve to FILTER for normal filtering.  Also use for regular Vacuuming. 

(B)

 

WASTE– To bypass filter for draining or lowering water level and for vacuuming heavy debris directly to WASTE. 

(C)

 

BACKWASH– 

a.

 

Shut off the pump. 

b.

 

Set Filter Control Valve to BACKWASH.   

c.

 

Start Pump and backwash approximately two minutes, or until water out waste line appears clean. 

d.

 

Shut off pump 

e.

 

Set Filter control valve to FILTER. 

f.

 

Proceed as in Pre-Coating to add fresh D.E. 

(D)

 

POOL OR SPA BOOST - Water is re-circulated through the pool system, bypassing the filter. 

Two-Position Slide Valve SP0410X502S 

(A)

 

FILTER – Set Valve to FILTER for normal filtering.  Also use for vacuuming (Handle in Down position). 

(B)

 

BACKWASH –  

a.

 

Shut off the pump. 

b.

 

Set valve to BACKWASH (UP position). 

c.

 

Start Pump and backwash approximately two minutes, or until water out waste line appears clean. 

d.

 

Shut off pump 

e.

 

Set Filter control valve to FILTER (DOWN Position). 

f.

 

Proceed as in Pre-Coating to add fresh D.E. for cleaning filter (Handle in Up position) 

 

MANUAL CLEANING 

 

 

Before manually cleaning the filter, backwash by following BACKWASHING instructions under each type of 

valve. 

 

 

WARNING 

 

  

This product should be installed and serviced only by a qualified professional. 

 

FILTER DISASSEMBLY INSTRUCTIONS 

 

1.

 

Turn off all system circulation pumps and all electric power on the pad. 

2.

 

Set all system valves in a position to prevent water flow to the filter. 

3.

 

The manual air relief valve must be placed in the OPEN position. (FIG 6) 

4.

 

Remove filter drain plug (FIG 4) and drain water from filter. 

5.

 

Using 3/4” wrenches, loosen and remove the clamp nut and the clamp bolt. (Fig 5) 

6.

 

Holding both ends of the filter body clamp carefully spread the clamp ends.  Remove the clamp by lifting over the 

upper filter body.  Do not to drop the clamp during removal because the clamp could be damaged.  Do not strike the 

clamp with metal tools as they can damage the clamp. 

7.

 

Lift off upper filter body.  Do not use the pressure gauge to lift the upper filter body. 

 

 

 

  

 

 

Summary of Contents for ProGrid DE2420

Page 1: ...ause serious personal injury death or major property damage and if ignored presents a potential hazard CAUTION warns about hazards that will or can cause minor or moderate personal injury and or prope...

Page 2: ...nts have a finite life the cover grate should be inspected frequently and replaced at least every SEVEN years or if found to be damaged broken cracked missing or not securely attached CAUTION Componen...

Page 3: ...e electrical equipment and have the problem corrected by a qualified service representative before using CAUTION HAYWARD pumps are intended for use with permanently installed pools and may be used wit...

Page 4: ...DE7220 52 0 132 18 46 25 63 DEP60 34 1 87 18 46 16 41 DEP80 40 1 102 18 46 18 46 DEP100 46 1 107 18 46 22 56 INSTALLATION WARNING Only simple tools screwdriver and wrenches plus pipe sealant for plas...

Page 5: ...3 0 1 4 DE3620 36 3 4 72 273 4 5 2 0 DE4820 48 4 5 96 363 6 0 2 7 DE6020 60 5 6 120 454 7 5 3 4 DE7220 72 6 7 144 545 9 0 4 0 DEP60 60 5 6 120 454 6 0 2 7 DEP80 80 7 4 150 568 8 0 3 6 DEP100 100 9 3 1...

Page 6: ...he instructions on page 7 in this owner s manual to stop leak 2 Return to filter to CLOSE manual air relief valve only when a steady stream of water not air or air and water mix is discharged from the...

Page 7: ...ASH c Start Pump and backwash approximately two minutes or until water out waste line appears clean d Shut off pump e Set Filter control valve to FILTER f Proceed as in Pre Coating to add fresh D E D...

Page 8: ...EMENT CLUSTER The filter element cluster can be cleaned by washing inside and outside with a garden hose After hosing filter element cluster for best results carefully brush the surface to remove fine...

Page 9: ...ce the filter clamp around the upper and lower filter bodies Hold the clamp ends to position the clamp on the filter bodies with the clamp ends adjacent to the safety and operation labels on the filte...

Page 10: ...INTERIZING FILTER In areas where subfreezing temperatures can be expected the filter should be drained to protect the filter from damage 1 The filter should be disassembled and the filter elements cle...

Page 11: ...DE6020 Retainer Rod DE7220 16 DEX2400CR Flex Air Relief Assembly 17 DEX2400Z5 Outlet Elbow O ring 18 DEX2420EA DEX3620EA DEX4820EA DEX6020EA DEX7220EA Outlet Elbow DE2420 Outlet Elbow DE3620 Outlet E...

Page 12: ...12 CX2030Z3 Air Relief Tube 13a DEX150E Cartridge Element DEP60 1 of 4 Required DEX150EPAK4 Cartridge 4 Pack DEP60 13b DEX200E Cartridge Element DEP80 1 of 4 Required DEX200EPAK4 Cartridge 4 Pack DEP8...

Page 13: ...ipment Hayward Pool Products warrants its products to be free from defects in materials and workmanship for a period of see below from the date of purchase Filters which become defective during the wa...

Page 14: ...on for those individual components Instead complete warranty registration only for the overall product using the serial number that is located on the outside of the product packaging Please include me...

Reviews: