background image

 

 

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 

 

 

2

 

 

 

 

 

 WARNING

 - 

Read and follow all instructions

 

in this owner’s manual and on the equipment. Failure to 

follow instructions can cause severe injury and/or death. 

 

WARNING

 

– Suction Entrapment Hazard.  

Suction in suction outlets and/or suction outlet covers which are, damaged, broken, cracked, missing, or unsecured can cause 

severe injury and/or death due to the following entrapment hazards: 

Hair Entrapment

- Hair can become entangled in suction outlet cover. 

Limb Entrapment

- A limb inserted into an opening of a suction outlet sump or suction outlet cover that is damaged, broken, 

cracked, missing, or not securely attached can result in a mechanical bind or swelling of the limb. 

Body Suction Entrapment

- A negative pressure applied to a large portion of the body or limbs can result in an entrapment.  

Evisceration/ Disembowelment

 - A negative pressure applied directly to the intestines through an unprotected suction outlet 

sump or suction outlet cover which is, damaged, broken, cracked, missing, or unsecured can result in evisceration/ 

disembowelment. 

Mechanical Entrapment

- There is potential for jewelry, swimsuit, hair decorations, finger, toe or knuckle to be caught in an 

opening of a suction outlet cover resulting in mechanical entrapment.

 

 WARNING 

- To Reduce the risk of Entrapment Hazards:

 

o

 

When outlets are small enough to be blocked by a person, a minimum of two functioning suction outlets per pump must 

be installed.  Suction outlets in the same plane (i.e. floor or wall), must be installed a minimum of three feet (3’)  [1 meter]  

apart, as measured from near point to near point. 

o

 

Dual suction fittings shall be placed in such locations and distances to avoid “dual blockage” by a user. 

o

 

Dual suction fittings shall not be located on seating areas or on the backrest for such seating areas. 

o

 

The maximum system flow rate shall not exceed the flow rating of as listed on Table 1. 

o

 

Never use Pool or Spa if any suction outlet component is damaged, broken, cracked, missing, or not securely attached. 

o

 

Replace damaged, broken, cracked, missing, or not securely attached suction outlet components immediately. 

o

 

In addition two or more suction outlets per pump installed in accordance with latest ASME, APSP Standards and CPSC 

guidelines, follow all National, State, and Local codes applicable. 

o

 

Installation of a vacuum release or vent system, which relieves entrapping suction, is recommended. 

 

WARNING

 

– 

Failure to remove pressure test plugs and/or plugs used in winterization of the pool/spa from the 

suction outlets can result in an increase potential for suction entrapment as described above. 

 

WARNING

 

– 

Failure to keep suction outlet components clear of debris, such as leaves, dirt, hair, paper and other 

material can result in an increase potential for suction entrapment as described above. 

 

WARNING

 

– 

Suction outlet components have a finite life, the cover/grate should be inspected frequently and 

replaced at least every SEVEN years or if found to be damaged, broken, cracked, missing, or not securely attached.

 

 

CAUTION

 

– 

Components such as the filtration system, pumps and heater must be positioned so as to prevent their 

being used as means of access to the pool by young children.  To reduce risk of injury, do not permit children to use or climb 

on this product.  Closely supervise children at all times.  Components such as the filtration system, pumps, and heaters must be 

positioned to prevent children from using them as a means of access to the pool. 

 WARNING 

– Hazardous Pressure.

 

 Pool and spa water circulation systems operate under hazardous pressure during 

start up, normal operation, and after pump shut off.  Stand clear of circulation system equipment during pump start up.  Failure to 

follow safety and operation instructions could result in violent separation of the pump housing and cover, and/or filter housing 

and clamp due to pressure in the system, which could cause property damage, severe personal injury, or death.  Before servicing 

pool and spa water circulation system, all system and pump controls must be in off position and filter manual air relief valve must 

be in open position.  Before starting system pump, all system valves must be set in a position to allow system water to return 

back to the pool.  Do not change filter control valve position while system pump is running.  Before starting system pump, fully 

open filter manual air relief valve.  Do not close filter manual air relief valve until a steady stream of water (not air or air and water) 

is discharged. 

 WARNING

 

– Separation Hazard.  

Failure to follow safety and operation instructions could result in violent separation of 

pump and/or filter components.  Strainer cover must be properly secured to pump housing with strainer cover lock ring.  Before 

servicing pool and spa circulation system, filters manual air relief valve must be in open position.  Do not operate pool and spa 

circulation system if a system component is not assembled properly, damaged, or missing.  Do not operate pool and spa circulation 

system unless filter manual air relief valve body is in locked position in filter upper body.  Never operate or test the circulation 

system at more than 50 PSI.  Do not purge the system with compressed air.  Purging the system with compressed air can cause 

components to explode, with risk of severe injury or death to anyone nearby.  Use only a low pressure (below 5 PSI), high volume 

blower when air purging the pump, filter, or piping. Use ONLY Hayward clamp system components: DEX2421JKIT clamp assembly, 

DEX2421J2 nut/bolt assembly, and a DEX2422Z2 metal reinforced seal.  Non-Hayward components may fail in use and cause 

explosive separation. 

Never rely on hand tightening the clamp nut to the clamp bolt.  Using a ¾” socket on a torque wrench, torque clamp nut and clamp 

bolt to 150 inch-lbs.  Before starting system pump, insure filter manual air relief valve body is in LOCK position in filter upper body. 

 

 

 

 

 

 

 

 

 

Summary of Contents for ProGrid DE2420

Page 1: ...ause serious personal injury death or major property damage and if ignored presents a potential hazard CAUTION warns about hazards that will or can cause minor or moderate personal injury and or prope...

Page 2: ...nts have a finite life the cover grate should be inspected frequently and replaced at least every SEVEN years or if found to be damaged broken cracked missing or not securely attached CAUTION Componen...

Page 3: ...e electrical equipment and have the problem corrected by a qualified service representative before using CAUTION HAYWARD pumps are intended for use with permanently installed pools and may be used wit...

Page 4: ...DE7220 52 0 132 18 46 25 63 DEP60 34 1 87 18 46 16 41 DEP80 40 1 102 18 46 18 46 DEP100 46 1 107 18 46 22 56 INSTALLATION WARNING Only simple tools screwdriver and wrenches plus pipe sealant for plas...

Page 5: ...3 0 1 4 DE3620 36 3 4 72 273 4 5 2 0 DE4820 48 4 5 96 363 6 0 2 7 DE6020 60 5 6 120 454 7 5 3 4 DE7220 72 6 7 144 545 9 0 4 0 DEP60 60 5 6 120 454 6 0 2 7 DEP80 80 7 4 150 568 8 0 3 6 DEP100 100 9 3 1...

Page 6: ...he instructions on page 7 in this owner s manual to stop leak 2 Return to filter to CLOSE manual air relief valve only when a steady stream of water not air or air and water mix is discharged from the...

Page 7: ...ASH c Start Pump and backwash approximately two minutes or until water out waste line appears clean d Shut off pump e Set Filter control valve to FILTER f Proceed as in Pre Coating to add fresh D E D...

Page 8: ...EMENT CLUSTER The filter element cluster can be cleaned by washing inside and outside with a garden hose After hosing filter element cluster for best results carefully brush the surface to remove fine...

Page 9: ...ce the filter clamp around the upper and lower filter bodies Hold the clamp ends to position the clamp on the filter bodies with the clamp ends adjacent to the safety and operation labels on the filte...

Page 10: ...INTERIZING FILTER In areas where subfreezing temperatures can be expected the filter should be drained to protect the filter from damage 1 The filter should be disassembled and the filter elements cle...

Page 11: ...DE6020 Retainer Rod DE7220 16 DEX2400CR Flex Air Relief Assembly 17 DEX2400Z5 Outlet Elbow O ring 18 DEX2420EA DEX3620EA DEX4820EA DEX6020EA DEX7220EA Outlet Elbow DE2420 Outlet Elbow DE3620 Outlet E...

Page 12: ...12 CX2030Z3 Air Relief Tube 13a DEX150E Cartridge Element DEP60 1 of 4 Required DEX150EPAK4 Cartridge 4 Pack DEP60 13b DEX200E Cartridge Element DEP80 1 of 4 Required DEX200EPAK4 Cartridge 4 Pack DEP8...

Page 13: ...ipment Hayward Pool Products warrants its products to be free from defects in materials and workmanship for a period of see below from the date of purchase Filters which become defective during the wa...

Page 14: ...on for those individual components Instead complete warranty registration only for the overall product using the serial number that is located on the outside of the product packaging Please include me...