background image

 

 

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 

 

 

10

 

 
 
 
 

REMOVING THE MANUAL AIR RELIEF VALVE 

 

WARNING 

Your Filter comes with a Manual Air Relief Valve (MAR) pre-installed from the factory. 

 

Only qualified pool professionals should service your filter’s Manual Air 

Relief Valve.

 

For Qualified pool professionals only:  If MAR valve needs to be serviced, follow these 

instructions carefully. 

1.

 

Turn off all system circulation pumps and all electric power on the pad. 

2.

 

Set all system valves in a position to prevent water from flowing to the filter. 

3.

 

The manual air relief valve must be placed in the OPEN position. 

4.

 

Wait until all water leakage has stopped. 

5.

 

Grasp the MAR body at the flats, turn the MAR counterclockwise until the 

indicator on the on the MAR flange is aligned with the “UNLOCK” position on the 

upper filter body. 

6.

 

Pull straight up to remove the MAR, a slight rocking motion may help. 

RE-INSTALLATION OF THE MANUAL AIR RELIEF VALVE 

1.

 

Check the o-ring seals, replace as needed. 

2.

 

With a clean cloth, wipe upper filter body and o-ring groove.  Remove all dirt and debris. 

3.

 

Align the notch in the MAR Flange with notch on top of the upper filter body. 

4.

 

Press the MAR straight down into the upper filter body 

5.

 

Turn the MAR clockwise until the indicator is aligned with the “LOCK” position on the upper filter body. 

6.

 

Verify the MAR discharge points away from all electrical connections. 

WINTERIZING FILTER 

 

In areas where subfreezing temperatures can be expected, the filter should be drained to protect the filter from damage. 

1.

 

The filter should be disassembled and the filter elements cleaned or replaced. 

2.

 

Follow directions under FILTER DISASSEMBLY INSTRUCTIONS 

3.

 

Then REMOVE FILTER ELEMENTS per instructions 

4.

 

Reassemble per the instructions on Page 8. 

5.

 

Be sure to leave the drain plug unattached during the winter season to avoid cracking the filter body. 

SERVICE AND REPAIRS 

Consult your local authorized Hayward dealer or service center.  No returns may be made directly to the factory without the 

expressed written authorization of Hayward Pool Products. 

SUGGESTED POOL CHEMISTRY LEVELS 

pH 

7.2 to 7.8 

TOTAL ALKALINITY 

80 to 120 ppm 

CALCIUM HARDNESS 

200 to 400 ppm 

COMBINED CHLORINE 

.2 ppm Maximum 

CHLORINE (STABILIZED) 

1.0 to 3.0 ppm 

CHLORINE STABILIZER  (Cyanuric Acid) 

60 to 80 ppm 

PROBLEM SOLVING LIST 

 

LOW WATER FLOW 

SHORT FILTER CYCLES 

POOL WATER WON’T CLEAR UP 

REMEDY 

1.

 

Check skimmer and pump strainer 
baskets for debris. 

2.

 

Check for restrictions in intake 
and discharge lines. 

3.

 

Check for air leak in intake line 
(indicated by bubbles returning to 
pool). 

4.

 

Backwash (Clean) Filter 

1.

 

Check for algae in pool and super-
chlorinate as required. 

 

2.

 

Be sure chlorine and pH levels are in 
proper range (adjust as required). 

1.

 

Check chlorine, pH and total alkalinity 
levels and adjust as required. 

2.

 

Be sure flow rate through filter is 
sufficient. 

3.

 

Operate filter for longer periods. 

 

Figure 10 

Manual Air Relief Shown Open 

In Locked Position  

Rotate counterclockwise to UNLOCK

 

Summary of Contents for ProGrid DE2420

Page 1: ...ause serious personal injury death or major property damage and if ignored presents a potential hazard CAUTION warns about hazards that will or can cause minor or moderate personal injury and or prope...

Page 2: ...nts have a finite life the cover grate should be inspected frequently and replaced at least every SEVEN years or if found to be damaged broken cracked missing or not securely attached CAUTION Componen...

Page 3: ...e electrical equipment and have the problem corrected by a qualified service representative before using CAUTION HAYWARD pumps are intended for use with permanently installed pools and may be used wit...

Page 4: ...DE7220 52 0 132 18 46 25 63 DEP60 34 1 87 18 46 16 41 DEP80 40 1 102 18 46 18 46 DEP100 46 1 107 18 46 22 56 INSTALLATION WARNING Only simple tools screwdriver and wrenches plus pipe sealant for plas...

Page 5: ...3 0 1 4 DE3620 36 3 4 72 273 4 5 2 0 DE4820 48 4 5 96 363 6 0 2 7 DE6020 60 5 6 120 454 7 5 3 4 DE7220 72 6 7 144 545 9 0 4 0 DEP60 60 5 6 120 454 6 0 2 7 DEP80 80 7 4 150 568 8 0 3 6 DEP100 100 9 3 1...

Page 6: ...he instructions on page 7 in this owner s manual to stop leak 2 Return to filter to CLOSE manual air relief valve only when a steady stream of water not air or air and water mix is discharged from the...

Page 7: ...ASH c Start Pump and backwash approximately two minutes or until water out waste line appears clean d Shut off pump e Set Filter control valve to FILTER f Proceed as in Pre Coating to add fresh D E D...

Page 8: ...EMENT CLUSTER The filter element cluster can be cleaned by washing inside and outside with a garden hose After hosing filter element cluster for best results carefully brush the surface to remove fine...

Page 9: ...ce the filter clamp around the upper and lower filter bodies Hold the clamp ends to position the clamp on the filter bodies with the clamp ends adjacent to the safety and operation labels on the filte...

Page 10: ...INTERIZING FILTER In areas where subfreezing temperatures can be expected the filter should be drained to protect the filter from damage 1 The filter should be disassembled and the filter elements cle...

Page 11: ...DE6020 Retainer Rod DE7220 16 DEX2400CR Flex Air Relief Assembly 17 DEX2400Z5 Outlet Elbow O ring 18 DEX2420EA DEX3620EA DEX4820EA DEX6020EA DEX7220EA Outlet Elbow DE2420 Outlet Elbow DE3620 Outlet E...

Page 12: ...12 CX2030Z3 Air Relief Tube 13a DEX150E Cartridge Element DEP60 1 of 4 Required DEX150EPAK4 Cartridge 4 Pack DEP60 13b DEX200E Cartridge Element DEP80 1 of 4 Required DEX200EPAK4 Cartridge 4 Pack DEP8...

Page 13: ...ipment Hayward Pool Products warrants its products to be free from defects in materials and workmanship for a period of see below from the date of purchase Filters which become defective during the wa...

Page 14: ...on for those individual components Instead complete warranty registration only for the overall product using the serial number that is located on the outside of the product packaging Please include me...

Reviews: